Manta Test Systems
Electrical utilities world-wide use our products to ensure the proper design, installation, and operation of protection systems critical to the reliability of the power system infrastructure.
- 1-800-233-8031
1-905-828-6469 - 1 (905) 828-6850
- sales@mantatest.com
- 4060B Sladeview Cres. Unit 1
Mississauga, Ontario L5L 5Y5
Canada
Categories
-
product
Digital Circuit Breaker Analyzer
CT-8000 S3
The CT-8000 S3 is Vanguard’s fourth generation EHV circuit breaker analyzer. The CT-8000 S3 is available with 3 (part number 9103-UC) or 6 contact timing channels (part number 9104-UC). The CT-8000 S3 can fully analyze a circuit breaker’s performance by measuring the main contact and resistor contact time, stroke, velocity, over-travel, bounce back and contact wipes. Also, an outstanding feature of the CT-8000 S3 is the ability to perform dynamic resistance tests on circuit breaker contacts.
-
product
Primary Current Injection
PCI-600
The VIC Model PCI-600 is a programmable, high-current source that is designed specifically for utility-substation applications. This alternating current(ac) test device is used primarily for injection testing of protective relays. This same device can also be used for testing thermal, magnetic and solid-state motor-protection relays and molded-case circuit breakers.
-
product
Seven-Module Test Set
F8300
Use the F8300 for testing three-phase conventional schemes and digital protection systems. This seven-module F8000-series instrument is available in five standard configurations of HVA Current, HVA Voltage, and Low-Density Logic I/O modules.
-
product
Digital Circuit Breaker Analyzer
CT-7000 S3
The CT-7000 S3 is Vanguard’s fourth generation EHV circuit breaker analyzer. The CT-7000 S3 is available with 3 (part number 9021-UC) or 6 contact timing channels (part number 9100-UC). The CT-7000 S3 can fully analyze a circuit breaker’s performance by measuring the main contact and resistor contact time, stroke, velocity, over-travel, bounce back and contact wipes. Both contact and motion analysis can be performed on all circuit breaker operations (OPEN, CLOSE, OPEN-CLOSE, CLOSE-OPEN, and OPEN CLOSE-OPEN). The CT-7000 S3’s timing window is selectable between 1 second, 10 seconds, and 20 seconds.
-
product
Leakage Current Monitor
LCM500
The Doble LCM500 Leakage Current Monitor can measure condition while a surge arrester is still in service, measuring the quality of the metal oxide blocks and helping manage the risk of failure.
-
product
Circuit Breaker Test System
TDR900
It operates and records a circuit breaker’s contact timing, motion, velocity, main contact engagement & synchronization, trip and close coil initiation and currents.
-
product
Circuit Breaker Test System
TDR9100
The Doble TDR9100 Circuit Breaker Analyzer is a state-of-the-art circuit breaker test set for testing all types of circuit breakers with efficient and accurate performance measurements.
-
product
Protection Testing Accessories
Protection testing programs can vary from team to team and company to company.
-
product
250 A Molded Case Circuit Breaker Tester
MCCB-250
The Vanguard MCCB-250 is a programmable, high-current source designed specifically for testing molded-case circuit breakers, thermal magnetic and solid-state overload motor-protection relays.
-
product
Vacuum Bottle Tester
VBT-75P S2
The VBT-75P S2 is Vanguard’s second generation microprocessor-based, portable 75 kV dc vacuum bottle tester. This lightweight, portable tester is designed for testing circuit-breaker vacuum bottles in the field and at the shop.
-
product
EHV Circuit Breaker Analyzer
DigiTMR S2
The Vanguard DIGITMR S2 is an inexpensive, easy to use digital circuit breaker analyzer. The DIGITMR S2 can be operated stand-alone or can be computer-controlled. It can fully analyze a circuit-breaker’s performance by testing the contact time, stroke, velocity, over-travel, and contact wipe. Contact and motion analysis can be performed for all breaker contact operations (Open, Close, Open – Close, Close – Open, and Open – Close – Open). Timing results are recorded and displayed on the 240 x 128 pixels back-lit LCD screen and can also be printed on the built-in 4.5″ wide thermal printer.














