IRIS Instruments
We bridge geophysics and digital with unmatched equipment that measure, process and interpret field data.
- +33 2 38 63 81 00
- info@iris-instruments.com
- 1 avenue buffon
Orléans, 45100
France
-
product
Receiver
Elrec Lite
The Elrec Lite G is a 2-channel hand held induced polarisation (IP) and Resistivity receiver mostly designed for mineral exploration. This low-weight device is particularly suited for sounding and profiling measurements where the operator must move from several hundreds of meters, carrying the receiver.
-
product
Resistivity Imaging & Sounding System
Syscal Junior Switch
The Syscal Junior is an all-purpose resistivity imaging and sounding system for environmental applications. The system can be supplied as a standard imaging system capable of recording two measurements simultaneously. The second recording channel significantly improves data acquisition time when the instrument is fitted with internal switching board for 24 (Switch-24) 48 (Switch-48) or 72 (Switch-72) electrodes for Electrical Resistivity Tomography (ERT).
-
product
Full Wave Recorder
I-FullWaver
The I-FullWaver systems were specifically developed for precise full waveform time domain induced polarisation, Resistivity and self-potential measurements. Each system is fully independent; incorporating its own power source, GPS module and digital memory for up to 3 months continuous recording.
-
product
Syscal R2
The Syscal R2 unit is a high-power system designed for DC electrical surveys applied to groundwater exploration, environmental studies, civil engineering, structural geology investigation and mineral exploration.
-
product
V-FullWaver
The V-FullWaver systems were specifically developed for precise full waveform time domain Induced Polarisation, Resistivity and SP measurements. Each system is fully independent; incorporating its own power source, GPS module and digital memory for up to 3 months continuous recording. The V-FullWaver is a dual channel Induced Polarisation, Resistivity and SP receiver. Continually recording at 10ms sample rate provides a full waveform record. It can be synchronized on the GPS PPS signal, allowing an easy process of the signal. Data on the memory can be downloaded directly on a simple USB stick from all the Fullwavers.
-
product
Syscal Junior
The Syscal Junior is an all-purpose resistivity and induced polarization sounding and profiling system for environmental applications. The system is supplied as a standard sounding system capable of recording two measurements simultaneously, perfect for performing offset Wenner sounding arrays. The output current is automatically adjusted (automatic ranging) to optimize the input voltage values and to ensure the best measurement quality.
-
product
Regulated Transmitter
VIP 5000
The VIP series of Electrical transmitters are purposely designed for deep Induced Polarisation or Resistivity sounding investigations. The VIP 5000 internal microprocessor is capable of excellent current regulation in almost any load. Predominantly used as part of mineral exploration studies, the VIP series include three systems with different power specifications. This transmitter is generally used together with V-Fullwavers or Elrec Pro receivers.
-
product
Syscal Kid Switch
Specifically designed for very shallow, high resolution resistivity sounding and profiling, the Kid is the most compact of the Syscal range whilst retaining the well-known reliability and measurement accuracy of its counter parts.
-
product
Elrec Pro Switch
The Elrec Pro Switch is a 10 channel Induced Polarisation (IP) and Resistivity receiver designed to improve productivity when recording deep profiles and soundings. Beside the classical arithmetic and logarithmic modes, ELREC Pro also offers a Cole-Cole mode and twenty fully programmable windows for a higher flexibility in the definition of the IP decay curve.
-
product
Full Wave Recorder
V-FullWaver
The V-FullWaver systems were specifically developed for precise full waveform time domain Induced Polarisation, Resistivity and SP measurements. Each system is fully independent; incorporating its own power source, GPS module and digital memory for up to 3 months continuous recording.
-
product
Syscal Pro
The Syscal Pro is an all-in-one multinode resistivity and induce polarization sounding and profiling system for environmental and engineering geophysical studies. The Syscal Pro gathers a 10 channels receiver and a 250 W internal transmitter which make it the more powerful system of the Syscal range. Compact, easy-to-use and field proof, the Syscal Pro measures both resistivity and chargeability. It is ideal for environmental and civil engineering applications such as depth-to-rock determination, weathered bedrock mapping. With a maximal output voltage of 2000Vpp, the Syscal Pro is very adapted to detect deep fault in fractured aquifers or to characterize the depths and thickness of the groundwater aquifers.
-
product
Regulated Transmitter
VIP 10000
The VIP series of Electrical transmitters are purposely designed for deep Induced Polarisation or Resistivity sounding investigations.
-
product
Receiver
Elrec 6
The Elrec 6 is a 6-channel Induced Polarisation (IP) and Resistivity receiver designed to improve productivity when recording deep profiles and soundings. Beside the classical arithmetic and logarithmic modes, ELREC 6 also offers a Cole-Cole mode and ten fully programmable windows for a higher flexibility in the definition of the IP decay curve.
-
product
Photon Magnetic Resonance
Numis Poly
The Numis Poly device is a Magnetic Resonance Sounding (MRS) system for the direct detection of shallow groundwater down to 150 m of depth
-
product
Electromagnetic
Promis 10
The Promis device is a multi-frequency, multi-spacing 3 component slingram type EM System for sounding and profiling the soil. This system features a transmitter loop to produce a primary magnetic field that will induce eddy current in conductive materials. These eddy currents will generate a secondary magnetic field that will be measured with the receiver loop. This system measures the in-phase and the out-of-phase components of the secondary magnetic field.