Dwyer Instruments Inc.
Since the company was founded in 1931, customers have come to recognize Dwyer Instruments to stand for quality, reliability, and readily available low cost products. As a leading manufacturer in the controls and instrumentation industry, we continue to grow and serve major markets including, but not limited to HVAC, chemical, food, oil and gas, and pollution control. New applications are discovered daily through a cooperative effort between Dwyer and its customers. It has been these relationships with our customers that allow us to continue to develop market demand products and further our success from leading established brand names such as the Magnehelic® pressure gages, Photohelic® switch/gages, Rate Master® flowmeters, and Hi-Flow® valves. In addition to new product development,
- 219/879-8000
- 219/872-9057
- lit@dwyer-inst.com
- P.O. Box 373, 102 Indiana Hwy. 212
Michigan City, IN 46361
United States of America
Categories
-
product
Stainless Steel Schaeffer Gage
SGO
The Series SGO Gages have dual English/metric scales with ±1.6% full scale accuracy. The Series SGO gages are designed with 304 SS housing, a 316L SS chamber and PTFE coated diaphragm for excellent chemical compatibility
-
product
Wet/Wet Handheld Digital Manometer
Series 490A
Liquid & Gas Pressure Measurement, ±0.5% FS Accuracy. The SERIES 490A Digital Manometers are versatile, hand-held, battery operated manometers available in several basic ranges for positive or positive differential pressure measurement and can tolerate most liquid media compatible with 316LSS. A new feature added to the Series 490A is a field adjustable damping, which allows the user to choose the level of display averaging rate corresponding to the fluctuation level common in many applications.
-
product
Gas Differential Pressure Switch
PG
Large sensitive diaphragm and reliable, time proven mechanical design are combined in Series PG pressure/differential pressure switches. For use with air and other compatible gases, they feature excellent ±1% of full scale repeatability, clear easy-to-read scale and convenient external setpoint adjustment.
-
product
Magnehelic Differential Pressure Gage
2000
Select the Magnehelic gage for high accuracy--guaranteed within 2% of full scale--and for the wide choice of 81 models available to suit your needs precisely. Using Dwyer's simple, frictionless Magnehelic gage movement, it quickly indicates low air or non-corrosive gas pressures--either positive, negative (vacuum) or differential
-
product
Temperature Controller
8C
The Series 8C Temperature Controller offers easy-to-use programming menus designed for quick installation. The unit is designed for direct or reverse acting (cooling or heating) control. The Series 8C can be programmed for simple ON/OFF or more complex PID control functions.
-
product
Weatherproof Pressure Transmitter
679
The Series 679 Pressure Transmitter is compatible with a wide range of gases and liquids, and is specially designed for weatherproof service (NEMA 4/IP56). The Model 679 can measure pressures with an accuracy of ±.25%. This model provides a 4-20 mA output and is field adjustable.
-
product
Explosion-Proof Differential Pressure Switch
H3
Explosion-proof, heavy duty, industrial unit has patented and unique new design which provides sensitivity to differential pressures as low as 10 inches of water (254 mm w.c.), yet handles total pressure of 1500 psi (103 bar). Unlike common differential pressure switches that use a piston-type motion transfer, the Series H3 utilizes a rotary motion transfer shaft that prevents a change in total pressure from causing a setpoint shift.
-
product
Magnesense Differential Pressure Transmitter
MS
The Series MS Magnesense Differential Pressure Transmitter is an extremely versatile transmitter for monitoring pressure and air velocity.
-
product
Air Velocity Meter
400
Measure both pressure and air velocityRead the red figures directly in feet per minute of velocity - from 400 to 10,000 fpm No conversion tables needed for air at standard conditions. Read the black figures in inches of water column air pressure - from 0 to 10" w.c.
-
product
Temperature Panel Meter
LTI
The Series LTI Temperature Panel Meters can be configured in a variety of configurations to provide visual indication and control of a process temperature. Field pluggable modules are available to add additional relay outputs, digital I/O ports, and serial communications. Utilizing an easy-to-read, dual 6-digit display, more descriptive programming parameters are displayed to simplify initial setup.
-
product
Differential Pressure Transmitter
616D
The Series 616D Differential Pressure Transmitter senses the pressure of air and compatible gases and sends a standard 4-20 mA output signal. The 616D housing is specifically designed to mount on a 35 mm DIN rail in a panel
-
product
SAFE-T-GROUND - Ground Continuity Monitor / Control
TR-7
Model TR-7 Safe-T-Ground provides continuous monitoring of a truck's ground connection throughout loading operations. Static electricity is often brought in by tank trucks entering the loading area. The Safe-T-Ground Model TR-7 instantly stops loading operations if a tank truck loses its ground.
-
product
Temperature/Process Controller
16B
Monitor and control temperature or process applications with precision using the Series 16B controllers. The units offer two separate outputs for dual loop control in direct or reverse acting. Select relay, voltage, or current output combined with a second relay output
-
product
Analog Panel Meter
APM
The Series APM has a unique, rugged, NEMA 4X front panel design that makes it nearly impenetrable in typical applications. The weatherproof, UV resistant, large, dual line display allows for more information making it easier to read and even simpler to program. The intensity of the display can be adjusted allowing this meter to be utilized in dark rooms as well as outdoors, due to its sunlight readable display.
-
product
Flex-Tube U-Tube Dual Range Inclined Manometer
1227
Use Series 1227 as a regular U-tube manometer to read high-range pressure on the right leg, or as an inclined manometer to read low-range pressure on the bottom leg. Simply incline manometer until fluid levels read zero. No spirit level required















