Amperis is a company specialising in state-of-the-art instrumentation for the diagnosis and testing of electrical substations. The company is located in the northwest of Spain, in the Polígono Industrial das Gándaras in the city of Lugo. After completing the construction and since November 2017 the company is located in the new headquarters, located at 14 Barbeito María Street. The new Amperis headquarters has offices and a new, more modern warehouse, with more internal conveniences and more facilities for the exit and entry of goods, with the aim of always providing a better service to the customer.
- (+34) 982 20 99 20
- info@amperis.com
- Barbeito María 14
Lugo, 27003
Spain
Categories
-
product
Transformer Winding Resistance Meters
RMO TT Series
The Tap Changer Analyzer & Winding Ohmmeter of the RMO-TT series is designed for winding resistance measurement of inductive objects, and for a tap changer analysis. The RMO-TT series is based on the state of the art technology, using the most advanced switch mode technology available today. The RMO-TT instruments are accurate (0,1%), powerful (up to 100 A) and still portable. The Instruments generate a true DC ripple free current with automatically regulated measurement and discharging circuit. RMO-TT instruments can perform a simple, quick and reliable transformer on-load tap changer condition assessment. This series of instruments enable measurements of a winding resistance in every tap position, current ripple values (percentage of a current drop during a tap change) and transition times during the tap changes. Problems with a connection, contacts, and selector/diverter switch operation (tap change with interruption) can be detected with these measurements.
-
product
Partial Discharge Detector
PXDP-II
The PXDP-II partial discharge meter is a portable device that performs detection and measurement of partial discharges in electrical devices or components. It records partial discharge measurements for analysis and diagnosis through the optional PC software. The PXDP-II can be used in various applications and complies with IEC 60270.
-
product
Loss Tangent M in Dielectric Oil
TAND220A
The measuring instrument type TAND220A complies with the international standard IEC 61620. The instrument is based on the so-called "low-amplitude, low-frequency alternating current square wave method" and allows accurate measurements of conductivity and relative permittivity. Conductivity measurement in the range of 0.01 pS/m to 20,000 pS/m allows the use of this instrument for quality control of high resistivity liquids even at room temperature. The TAND220A works with a low test voltage and also with a low test current so that it does not represent a danger for the operators.
-
product
Distribution Transformer Tester
ADOC-3
The ADOC-3 is an equipment that has been designed to test distribution network transformers from 5 kVA to 3MVA.
-
product
Powerline Analyzer
NEXUS 1272
The Nexus 1262/1272 meters provide the most comprehensive electrical analysis available in a socket type meter. This unit offers extensive advanced monitoring features to meet the most stringent power monitoring requirements. Using advanced technology, the Nexus measures and immediately stores Power billing data along with superior Power Quality and communication.
-
product
Switch Analyser
SA10
The SA10 equipment is designed to be used together with a personal computer even in those cases where fundamental tests can be performed without human presence (standalone).
-
product
Circuit Breaker Analyzer
CAT Standard Series
The CAT Standard series circuit breaker analyzers & timers are stand-alone or a PC-controlled digital instruments for circuit breakers condition assessments. The timing channels record closing and opening of the arcing, resistor, and auxiliary contacts. CAT Standard series records graphs of both, trip and close coil currents and displacements of the HV and MV circuit breaker moving parts. The main contact channels can also measure the resistance value of the pre-insertion resistors (if present in the circuit breaker). Test results can be downloaded to a USB memory stick or saved to internal memory. The CAT Standard series internal memory can store up to 500 test results (numerical and graphical data). Test results can also be printed on the 80 mm (3.15 inch) thermal printer (optional accessory) in tabular and graphical form. CAT Standard series provides an easy selection of different operational modes:
-
product
Partial Discharge Meter
APD-LT
The APD-LT equipment is a partial discharge meter in cable accessories (heads or insulators) to improve safety and maintenance. The PD level is presented numerically in the wireless unit.
-
product
Transformer Winding Resistance Meters
RMO TD Series
The RMO-TD Series On-Load Tap & Winding Resistance Analyzer is designed for the measurement of winding resistance of inductive elements, and for tap changer analysis. The RMO-TD series is based on the latest technology, using the most advanced switching technology available today. The RMO-TD series is accurate (0.1%), powerful (up to 60 A) and lightweight. It generates true, ripple-free DC current with automatic metering control and a discharge circuit.
-
product
Ohmmeter
PDRM-10A
The PDRM-10 A ohmmeter, with a range of 0.01µΩ to 200 Ω is currently the most accurate and highest resolution ohmmeter on the market, and at only 860 g it is also the lightest and most compact. All this has made it the standard low resistance ohmmeter in many electrical companies, industries and assembly companies. It has a resolution of 0.01µΩ.
-
product
Microhmmeter
RMO-G
The RMO-G series micrometers are designed with the latest technology to generate a DC ripple-free current with automatically regulated test ramps, no magnetic transients and very efficient filtration.
-
product
Transformer Ratio Meters
The TRT is based on state-of-the-art technology and uses the most advanced technique available today. The test equipment can be used to test both single-phase and three-phase transformers, both with and without tap changer in accordance with the requirements of IEC 60076-1.
-
product
Telurometer
AMRU-200
*The only meter on the market that implements all measurement methods:*Technical method of 2, 3 or 4 poles*Drive method (4/10μs, 8/20μs, 10/350μs).*Double-clamp method without the need for auxiliary electrodes.*Soil resistivity.
-
product
Power Quality Analyzers
APQM-702/APQM-703
It can be powered from the L phase.It is intended for use in virtually all types of networks from 64 V to 760 V directly, with special consideration for measurements on low-voltage poles, due to its ease of connection.It has an independent power supply and is therefore particularly suitable for measurements outside of voltage transformers. It can also be adapted for measurements on DC voltage systems.Real-time remote configuration and data transfer (GPRS) using a built-in GSM modem
-
product
Insulation Resistance Meter
AMIC-10k1
Insulation resistance measurement - 40TΩ: * 50 - 1000 V, in 25 V steps, * 1000 - 10000 V, in 50 V steps ; Memory, bluetooth keyboard option, heating location ; Measurement of AC and DC voltage and capacity ; Measurement of leakage current and function with digital filter ; Measurement of continuity of protection and equipotential connections ; Adjustable alarm limits.