Cryogenic Ltd.
enowned in low temperature research and material science laboratories world-wide for delivering high quality measurement systems and providing the highest magnetic fields (up top 25 Tesla) and lower temperatures (down to 10mK)
- 44(0)20 8743 6049
- 44(0)20 8749 5315
- sales@cryogenic.co.uk
- Unit 6, Acton Park, Industrial Estate
The Vale, Acton
London, W3 7QE
United Kingdom of Great Britain and Northern Ireland
-
product
Neutron Scattering and Beamline Systems
For optical, neutron and particle beam experiments, Cryogenic offers a range of split pair magnets. These allow strong magnetic fields to be produced in a small volume with maximum access to the working space. Split pair coils can be mounted to provide either a vertical field with horizontal access or a horizontal field offering horizontal or vertical access.
-
product
AC Susceptibility
The AC Susceptometer option uses a small primary excitation coil to apply an AC field to a sample (typically 1mT at frequencies from 0.1 Hz 10000 Hz). A pair of secondary pick-up coils positioned close to the excitation coils are used to detect the sample response.
-
product
Mini-MRI Systems
Magnets for Magnetic Resonance Imaging (MRI) are required to generate a high homogeneity field over the imaging volume which remains stable in time.
-
product
High Temperature VSM probe
To perform measurements at or above room temperature, separate heated sample probes are offered for electrical or magnetic measurements. In normal operation, the CFMS has a continuous temperature range of 1.6 K to 400 K. With these inserts the range can be extended up to 1000 K.
-
product
Vibrating Sample Magnetometer
VSM
The Cryogenic Vibrating Sample Magnetometer (VSM) is designed for measurement of the DC magnetic moment of a sample with a noise floor sensitivity of 10-6 and at 10 seconds integration time.
-
product
Thermal Transport
The thermal transport probe measures thermal conductivity and thermoelectric power (defined by the Seeback Coefficient). Electrical and thermal contacts are made to opposite ends of the sample allowing for customisation to suit the sample requirements of the user.
-
product
Resistivity and Hall Effect
The Resistivity System allows the user to make Resistivity and Hall Effect measurements in the range of to M. Samples are mounted on special platforms inside the VTI with contacts made to the sample according to the customer's requirements.
-
product
Magnet & Integrated Variable Temperature Sample Space With DR Insert
Adapted MCK model DR inserted into 50 mm 1.6 K300 K VTI VTI cooling power used for condensing stage of DR Versatile solution as the magnet system can also be used with other inserts and measurement probes including He3, heated probes, rotator, VSM etc.
-
product
Mini Cryogen Free Systems
mCFMS
Cryogenic offers cryogen free measurement systems, which include a cryocooler, cryostat with superconducting magnet (3, 5, 7 or 9 Tesla), variable temperature sample space, a selection of special probes for measurements of different physical properties, as well as electronics, computer and measurement software.
-
product
Cryogen-Free DR With Integrated Magnet
Magnet thermally linked to cryocooler 2nd stage Ideal for smaller magnets up to 17 T or small vector magnets up to 7T / 2T / 2TSingle pulse tube cryocooler for cooling both magnet and DRMagnet operation at 700 mK or 4 KUse with top-loading probeFast Sample Change
-
product
Free DR and High Field Magnet in Shared Vacuum Space
50 mm 4 K magnet bore, 30 mm sample space in DRSuitable for use with Leiden DR type CF200, CF450, CF650 or CF1000 DR
-
product
SQUID Magnetometer
S700X
The S700X SQUID Magnetometer is the most sensitive instrument for DC and AC measurement of magnetic properties as a function of magnetic field and temperature. Numerous different experiments may be performed with this unique instrument.
-
product
High field Superconducting Magnets
Cryogenic Ltd manufactures a wide range of superconducting magnets for research and industrial purposes. A range of standard solenoids between 1 to 22 Tesla is produced, and in addition split pair solenoids in the range 1 to 14 Tesla, with a typical central field homogeneity of 0.1%.
-
product
Solid State NMR
Magnets for NMR experiments are required to have a high homogeneity, which can be maintained over a wide range of field. Experiments are performed at fixed frequency and the spectrum is obtained by sweeping the magnetic field. This requires the field to be stable in spatial homogeneity and change steadily and repeatedly over time.
-
product
Free Room Temperature Bore Systems
The cryomagnetic system contains the cryogen free room temperature bore superconducting magnet, cryostat, cryocooler and compressor, temperature monitor unit (nominally Lakeshore) and HTS current leads. The cooling for the magnet and cryostat housing is provided by a standard cryocooler with a base temperature of 4K. The magnet is designed to operate safely at the guaranteed field without quenching.