Network Technologies Inc
Network Technologies Inc (NTI), based in Aurora, OH (USA), is a leading global provider of high quality IT infrastructure management solutions. NTI products are used worldwide by leading companies in every industry, including manufacturing, retail, government, education, healthcare, financial services, entertainment, worship, broadcast, and telecommunications.
- 800-742-8324
330-562-7070 - 330-562-1999
- sales@ntigo.com
- 1275 Danner Dr.,
Aurora, OH 44202
United States of America
-
product
Industrial Serial GSM Modem
ENVIROMUX-GSM-IND
Sends SMS messages to a pager or cell phone when a sensor goes out of range of a configurable threshold. SIM card supporting SMS messaging required (not included). Ideal for harsh environments and high temperatures up to 149°F (65°C). GSM/GPRS/EDGE 850/900/1800/1900 MHz. AT command compatible. Dimensions: 3.58x2.28x0.87 in (91x58x22 mm). Operating temperature: -13 to 149°F (-25 to 65°C). Operating humidity: up to 95% non-condensing RH. Regulatory approvals: CE, C-Tick. Compatible with ENVIROMUX-SEMS-16(U).
-
product
Rugged Door Contact Sensor
ENVIROMUX-DCSR
Monitors access with a magnetic bridge sensor (no special inserts necessary). Ideal for commercial and industrial installations in harsh environments. Heavy-cast aluminum housing with 18-inch stainless steel armored cable. Floor-mounting hardware included. For normally open or normally closed circuit connection. Wide actuating gap, approximately 3". Maximum cable length: 1,000 ft (305 m). Dimensions WxDxH (in): Magnet: 3.5x1.5x1.5 (89x38x38 mm), Switch: 3.5x1.5x0.44 (89x38x11 mm). Regulatory approvals: UL.
-
product
Glass Break Detection Sensor
ENVIROMUX-GBS
Acoustically detects the cracking of glass. Adjustable sensitivity. Includes mounting hardware. Connect to RJ45 or digital input sensor ports. Supports CAT5/5e/6 UTP or STP cables. Screw terminal. To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal. Maximum cable length: 1,000 ft (305 m). Powered by ENVIROMUX-2D/5D/16D.
-
product
Duct Mount Temperature/Humidity Sensor
ENVIROMUX-STHS-DCT
Combines excellent stability with easy installation and reliable operation. Duct Mount ENVIROMUX-STHS-DCT: Applications from 14 to 140°F (-10 to 60°C). Temperature accurate to within ±0.54°F (±0.3°C). Relative Humidity accurate to better than ±3% from 10 to 90% relative humidity at 68°F (20°C). Insensitive to dust and most chemicals. Requires the ENVIROMUX-S420MA-24V to operate. Maximum cable length: 500 ft (152m). Regulatory Approvals: CE, RoHS. Enclosure: IP65, NEMA 4.
-
product
HDMI Extender via One SC Multimode Fiber Optic Cable to 3,280 feet
ST-FOHD-SC50
The XTENDEX® HDMI Extender via Fiber Optic Cable locates an HDMI display up to 3,280 feet (1,000 meters) away from a video source using a single SC multimode fiber optic strand. Each extender consists of a transmitter that connects to a video source and a receiver that connects to a display.
-
product
4-20mA Sensor Converter
ENVIROMUX-S420MA-24V
External RJ45 device monitors up to two 4-20 mA analog sensors. Supports ISA Type 2, ISA Type 3, and ISA Type 4 sensors. Provides 24VDC, 25mA for each sensor. Connector: Screw Terminal, 8-position. Supports CAT5/5e/6 cable up to 500 ft. (152 m). Includes Mounting Hardware. Powered by ENVIROMUX-2D/5D/16D. Compatible with ENVIROMUX-2D/5D/16D. Regulatory approvals: RoHS.
-
product
3-Phase AC Voltage Transducer
ENVIROMUX-PT3-600
Monitors and reports voltage of any 3 phase circuit. Remotely detect blown fuses or tripped circuit breakers. Three 600 VAC inputs, three 4-20 mA outputs. Inputs and outputs isolated from one another. Frequency: 50/60Hz. Maximum primary current: 600 volts. Accuracy: ±0.25% F.S. @60Hz. Output: 4-20 mA. "Zero" adjustment for accurate 0 VAC reading, and "Calibration" adjustment for frequency and voltage level. Powered by the ENVIROMUX-S420MA-24V. Regulatory approvals: UL, CUL, CE. Requires two ENVIROMUX-S420MA-24V to monitor three phases. Caution: installation should be performed by qualified electricians only. Make sure electrical service is disconnected before making any electrical connections.
-
product
HDMI HDBase-T Extender with IR
ST-C6HD-HDBT
The XTENDEX® HDMI HDBase-T Extender transmits uncompressed digital HDMI signal and IR up to 328 feet over a single CAT5e/6/7 cable using HDBase-T technology. Each video extender consists of a local unit that connects to an HDMI source and a remote unit that connects to an HDMI display.
-
product
Legacy Liquid Detection Rope Sensor
ENVIROMUX-LDSx-y
For warning of flooding. Detects liquid depth >0.1" (2.5 mm). Minimum puddle: 0.6" (15 mm) diameter. 100% waterproof electronics. Detects any liquid or moisture, except deionized water. RJ45 connector. Voltage Supply: 12VDC. Current Consumption: 20mA. Supports CAT5/5e/6 cable up to 1,000 ft. (305 m). Available water sensor cable (x) lengths: 1/10/50/100/200/400/600/800/1000 feet. Plenum rating: CL2P (UL). Available 2-wire cable (y) lengths: 5/10/20/50/100 feet. Powered by ENVIROMUX-SEMS-16U and SERIMUX-S-x. Regulatory approvals: CE, RoHS. Requires the ENVIROMUX-SEMS-16U and SERIMUX-S-x to operate. Use self-adhesive clips (ENVIROMUX-CLP10-LD) to prevent sensor rope cable from shifing after installation. ENVIROMUX-CLP10-LD includes 10 clips.
-
product
Weather Resistant Surge Protector for RS485 Control & 12VDC Power Lines
SP-RS485-12V-O
Ideal for applications such as video surveillance cameras and access control. Protects sensors running on 22 AWG 2-wire sensor cables or 12VDC power lines against the effects of electrostatic discharge, faulty wiring and lightning. RS485 protection: Stage 1 clamping voltage: ±90V; Stage 2 resistance: 3.3 Ohms; Stage 3 clamping voltage: ±7.5V. 12VDC power lines protection: Stage 1 clamping voltage: ±90V; Stage 2 current rating: 3A; Stage 3: 12V TVS (transient voltage suppression) diode. Screw terminal pairs for RS485 and 12VDC power lines protection. Will also protect two single ended data, analog or control lines. Impact and weather resistant enclosure with locking hinged cover.
-
product
Carbon Dioxide Sensor, CO2
ENVIROMUX-CO2
CO2 room sensor for periodically unoccupied areas. Measures CO2 in a range of 0 to 2,000 ppm. 0 to 5 VDC output. Continuous automatic air pressure compensation. LED indicators for operation status and system test. Maximum cable length: 1000 ft (305m). Powered by ENVIROMUX-2D/5D/16D. Regulatory approvals: RoHS.
-
product
High-Mount Outdoor Infrared Motion Sensor
ENVIROMUX-IMD-OHM
High-mount outdoor weatherproof sensor with 94 detection zones. Unique pyro-element provides multiple pattern detection and accurate discrimination function for spot temperature changes of moving objects. Drastically reduces false and missed alarms caused by severe outdoor environmental changes. Upper and lower area must be activated to generate an alarm condition. Summer night compensation, advanced temperature compensation, and vegetation sway analysis logic. Ideal detection area setting – adjustable length/spot detection. Registers movement in area covered: 13/18/30/40 ft and 85° wide. LED indicators for operation and system status. Unwanted detection areas can be eliminated using the included area masking seal. Mounting height: 8.3 to 10 feet. Tamper switch opens when cover is removed. Screw terminal. To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal. Operating temperature: -4 to 140°F (-20 to 60°C). IP54 compliant. Powered by ENVIROMUX-2D/5D/16D.
-
product
Smoke Detection Sensor – 120VAC Wire-In with Battery Backup
ENVIROMUX-SDS-120V
For warning of smoke and invisible fire particles. Ionization smoke detector. Applications from 40°F to 100°F (4°C to 38°C). Front loading battery door. 9V battery backup (included) in case of power failure. One button design for easy testing and HUSH mode activation control. LED indicates four modes of operation: standby condition, alarm condition, alarm memory and hush mode. Hush mode: silences false alarms for 8 minutes, or low battery warning for 13 hours. Voltage supply: 120VAC. Pre-stripped wiring harness with tinned strands. Audio alarm: 85dB at 10ft. Dimensions: 5" diameter x 1.75" depth. Dust cover prevents false alarms. Tamper resist feature. Links with up to 24 devices. Max distance between first and last device: 1000ft (305m). Alarm memory indicates initiating alarm in interconnected systems. Use compatible relay (ENVIROMUX-RLY-SDS120V) for connection to the ENVIROMUX system or other auxiliary warning devices such as external sirens or stairwell lighting. ENVIROMUX-RLY-SDS120V includes normally open and normally closed contacts. Contact ratings: 10A at 120VAC, 5A at 30VDC. Regulatory approvals: UL.
-
product
USB Extender via CAT5 to 200 Feet
USB-C5-200
The USB-C5-200 extends up to four self-powered or bus-powered USB devices to 200 feet. The USB extenders consist of two units, the local unit and the remote unit, which are interconnected with CAT5/5e/6/7 cable.
-
product
RS232 Extender via One CAT5e/6 up to 3,935 Feet
ST-C5RS-LC
The XTENDEX® RS232 Extender extends one RS232 serial device up to 3,935 feet over a single CAT5e/6/7 cable.