Product
Micro-Ohmmeter Calibration Kit
LOM-530
-
The LOM-530 is convenient single unit containing a complete set of (5) working standard grade resistors for complete calibration of micro-ohmmeters. The standard resistance values are those used by the LOM-510A Microohmmeter/Milliohmmeter.
-
Product
Digibridge
1659
-
The GenRad 1659 Digibridge RLC Tester is an easily programmable, microprocessor-based high performance passive component tester. It automatically identifies the type of component under test and measures in the proper range. The result is simple, precise, unambiguous RLC component testing. The GenRad 1659 RLC Digibridge is an instrument for measuring primary parameters of inductance (L), capacitance (C) and resistance (R) and secondary parameters of dissipation factor (D) and quality factor (Q). GenRad designed this single compact unit with maximum flexibility and operator convenience in mind. The simple front panel design of the Digibridge requires less effort to operate. Digital display and user friendly control allows test parameters and limits to be set easily.
-
Product
Standard Capacitors
1408 Series
-
Ultra-high stability. The continuously improvingaccuracy of capacitor calibrations by NISTbrings a better knowledge of capacitance tostandards laboratories - provided, of course,the laboratories have adequate referencestandards. The 1408 Reference Standard Capacitors,with their high stability, are suitablefor calibration in parts in 107. The 1616 PrecisionCapacitance Bridge is highly recommendedfor accurate calibration of a wide range ofworking standards from such a reference.
-
Product
Decade Resistor
1433 Series
-
The 1433 Decade Resistors are primarily intended for precision measurement applications where their excellent accuracy, stability, and low zero resistance are important. They are convenient resistance standards for checking the accuracy of resistance-measuring devices and are used as components in dc and audio-frequency applications.
-
Product
Precision Impedance Meter
1689
-
The GenRad 1689 Precision Impedance Meter gives you the best performance for your most demanding applications whether they be production test, incoming inspection, component design and evaluation, process monitoring or dielectric measurement. It is a versatile, full function microprocessor-based passive component tester that's available in a rack mountable, (1689M) model.
-
Product
Oil Immersed Transfer Standard
esi SR1030 Series
-
The esi SR1030 transfer standards consist of 12 equal steps. These steps are available in increments of 1 (SR1030-1), 10 (SR1030-10), 100 (SR1030-100), 1k (SR1030-1k), 10k (SR1030-10k) and 100k (SR1030-100k). The esi SR1030 provides four-terminal connections for each step or for series and parallel combinations of these resistance steps using the optional Series-Parallel (SPC102), Parallel Compensation Networks (PC101) and shorting bars (SB103). This improves power dissipation, stability and errors due to variance in temperature. The esi SR1010 and esi SR1030 are used for the same applications and are alike in configuration. The esi SR1030 differs from the esi SR1010 in that it is specially sealed, and values below 100 k are filled with oil to improve changes due to thermal variations.
-
Product
Decade Capacitor
GenRad 1423-A
-
The GenRad 1423 decade capacitor is a versatile tool for calibration laboratories and production-line testing. With it a bridge can be standardized to an accuracy exceeded only by that of the highest quality, individually certified laboratory standards such as the GR 1404 Reference Standard Capacitors.Used with a limit bridge, such as the GR 1689 Digibridge, the 1423 facilities fast and accurate production-line measurements of arbitrary capacitancevalues with minimum setup time.
-
Product
Cost Effective Capacitance Decade Box
CS Series
-
The CS Series Capacitance Decade Box is a cost effective and commonly used capacitance decade box for production and educational applications
-
Product
Primary Standard Capacitors
GenRad 1404 Series
-
The GenRad 1404 Series standard capacitors are the standard of choice in metrology labs, and still used today by standards bodies around the world. These capacitors have been designed as primary reference standards of capacitance with which working standards can be compared.
-
Product
Programmable Capacitance Decade Box
PCS Series
-
A broad range of laboratory grade programmable capacitance decade boxes for applications requiring a programmable impedance unit controlled manually and by a computer via an IEEE-488, RS-232 interface.
-
Product
Standard Capacitor
1409 Series
-
The elements used in 1409 Standard Capacitors are selected for low dissipation factor and are stabilized by heat cycling. They are housed in cast aluminum cases, along with silica gel which provides continuous desiccation. These cases are sealed with high-temperature wax. A well is provided in the wall of the case for insertion of a dial-type thermometer. Three jack-top binding posts are provided on the top of the case, and removable banana plugs on the bottom, for convenient parallel connection without error
-
Product
Precision Decade Capacitor
Genrad 1413
-
Six precision decades are employed to provide a range of 0 to 1.11111 F in increments of 1 pF and with an accuracy of 0.05% +0.5pF. Air capacitors are used for the two lower decades and highest grade mechanically stabilized sealed India Ruby mica capacitors are used for the remainder. Air trimmers are used for trimming the two lowest silvered-mica decades. The stability of the 1413 is such that it should not require readjustment with normal service. However, should it become desirable,the four lower decades contain trimmer capacitors that are accessible for this purpose.
-
Product
Capacitance Standard
SCA Series
-
The SCA Standard Capacitor series are highly stable cost-effective capacitance standards with low temperature coefficient, low losses and a wide range of values of 1 pF - 10,000 F. The cost and flexibility make this our most popular capacitance standard.
-
Product
Hipot Current Calibration Load Resistors
HPRS-HIPOT-LOAD
-
The IET HPRS-Hipot-Load is an excellent replacement for the Fluke 5320A-Load Hipot current calibration load resistors. The IET high power resistive load can be used with the Fluke 5320A Multifunction Electrical Tester Calibrator or standalone. It provides a high power and high voltage load to various hipot tester to create the leakage current needed to calibrate various manufactures hipot testers.
-
Product
Capacitance Bridge
1620
-
The GenRad 1620-A Capacitance Measuring System is a self-contained assembly of the GR 1615-A Capacitance Bridge with appropriate oscillator and null detector for measurements at 11 frequencies between 20 Hz and 20 kHz. For applications requiring other or higher frequencies, to 100 kHz, the 1615-A bridge can be supplied separately and the oscillator and detector selected to meet your needs.