Pulsed Lasers
A single or repetitive burst of laser energy with a pulse equal to or less than 0.25 s in duration.
See Also: Autocorrelators
-
Product
Analog Laser Power Probes
-
Laser power measurements should be quick and easy. They should not involve time consuming set-up and alignment problems. Ideally, the measurements should also be able to be made at any point in an optical system where losses are likely to occur. Unfortunately, most laser power meters have sacrificed ease of use to gain continuous power readings.
-
Product
Multi-Role, Low-SWaP Laser Target Designator
StormCaster™-DX
-
The Teledyne FLIR StormCaster™-DX is a multi-role, low-SWaP laser target designator payload designed to affect the STANAG-compliant terminal guidance of laser guided munitions. StormCaster-DX is tightly integrated with the R80D SkyRaider™ UAS to leverage its class-leading payload capacity, multi-mode operations (tethered/untethered & mounted/dismounted), and AI-CV-based targeting capabilities.
-
Product
Laser Head Cable, 3 m
10881D
-
Provide reliable power with this spade lug that connects the laser head to multiple laser boards.
-
Product
PC Control Tunable Laser Source Modules
UC9710xx
-
The UC8710C, UC9710L and UC8710CL tunable laser modules offer superior performance in testing DWDM components, AWG & PLC components, and optical amplifiers, and performing other general- purpose fiber optical test and measurement applications particularly in fiber grating sensor fast sweep testing.
-
Product
Video Pulse Generator
MS 1811
-
*4 Channels of Variable Pulse / Amplitude Output*Pulse Generation Delay between any Two Channels can be Programmable between 2ns to 1ms*Pulse Width can be programmed from 20ns to 268ms (Range: 60ns � 2Sec, Resolution: 2ns, Accuracy: �5ns)*Programmable Pulse PRI (Range: 0ns � 2Sec, Resolution: 10ns, Accuracy: �5ns)*Delay Amongst Channels (Range: 0 � 1.34S, Resolution: 2ns, Accuracy: �5ns)*Rise Time and Fall time is less than 5ns (Programmable Slew Rate 2ns to 10ns � Optional)*Pulse Amplitude can be Programmed between 50mV to 6V (Range: 0 � 6V, Resolution: 10mV)*Channels can be terminated with different loads (50W,75W and 90W)*Standard ISA Bus Interface*Clock (Frequency: 100MHz, Source: Internal/External)*Driver interface for Windows2000/XP/VISTA and LINUX OS
-
Product
SF30/D High-speed Laser Rangefinder – 200 M
28062
-
sensor in the SF series. This 200 m sensor is known for its high speed, accuracy and performs well in even the most challenging conditions.
-
Product
3D Laser Imager
Vector-DD
-
The Vector 3D laser imager offers multi wavelength, full waveform data capture, coupled with the flexibility of an all-sky scanner. The Vector-DD is a direct detection (DD) 3D (range, angle, angle) active imager with an all-sky full hemisphere scanner. It employs a nodal point design so that all the lines-of-sight converge to a single point at the instrument*. In addition, two wavelengths can be transmitted so that differential reflectivity information can be derived. The unit is compact and portable and operates from 24V DC.
-
Product
Tunable Diode Laser Absorption Spectroscopy
5100 TDLAS
-
The feature-rich 5100 TDLAS offers high-sensitivity, analyte-specific, fast-response measurements for critical industrial applications. It features a single absorption cell and integrated sample system in a compact, cost-effective package.
-
Product
Diode Lasers
Spot Creator
-
Advanced Photonic Sciences LLC
Spot Creator is an innovative accessory developed for enhancing the performance of blue laser diode based engraving and cutting machines. Spot Creator solves a major problem with using asymmetric blue laser diodes: the production of engraving features that are different in the X-Y directions, resulting in unequal or blurred lines. Using Spot Creator, line widths are equal in the X-Y directions, with a minimum spot of 50 μm. The intensity on the engraved part is thus maximized.
-
Product
Micromachining Laser Systems
-
Versatility in terms of materials Taper controlled drilling Only top – quality components Intelligent laser machining software Beam focus adjustment Beam power (pulse energy) control Many options for system customization Table top system Small footprint Cost effective workstation User-friendly, flexible, upgradeable system control
-
Product
150 A, 5 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 6 Meter Cable
CP150-6M
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
Electro Optical Terahertz Pulse Reflectometry
EOTPR 3000
-
The EOTPR 3000 system is configured with a manual probe station to meet today’s tough FA environment which requires to isolate fault location in minutes rather than hours or days, while maintaining the EOTPR’s world leading sub-5 μm fault isolation accuracy.
-
Product
Small Fanless 3D Control FAYb Laser Marker
LP-M Series
-
Panasonic Industrial Devices Sales Company of America
The LP-M series offers a small, fan-less head design with an IP64 protection to prevent dust and water entering from any direction. The 3D Control capability allows marking on various types of products and complicated shapes to meet a large number of application needs. - 20, 50 & 100 Watt Models- Compact IP64 Rated Head- Full 3D Features- Auto Focus capable- Redundant Safety Features
-
Product
Guidance Laser with Remote In-Cab Line Adjust
GL3000P
-
The GL3000P Guidance Laser uses an ultra high visibility green laser to establish visual line control for the vehicle driver. Used for highway paint striping, asphalt distributors, road wideners, pavement profilers, or virtually any application requiring vehicle line control. GL3000P model is for truck cab mounting.
-
Product
Optical SpO2 Pulse Oximeter Simulator
OX-1 OxSim®
-
Test the complete SpO2 system, including the sensor, extension cable with the OxSim® Optical SpO2 Pulse Oximeter Simulator. Slips into your shirt pocket and operates easily with just two buttons on a single AA battery. The auto-detection of the Sensor type eliminates the need to select the manufacturer oximeter under test. The optional serial communications port enables users to expand simulation settings for Saturation, Pulse Rate, and Perfusion Index, ideal for applications where a wide range of simulations is needed.
-
Product
Laser Diameter Measuring Instrument
RC-078
-
The RC-078 Laser Diameter Instrument is a high accuracy one without contacting designed on the basis of the laser scan measuring principle. The 2-dimension measuring mode is applied to the instrument, and the 2-way laser beam is in the positive cross design in the measuring field, thus effectively eliminating testing errors caused by work piece shocks. It is special suitable for real-time measurement of the production field, and widely used in the test of round wire materials such as communication cables, optical cables, co-axial cables and power cables, and the test of various kinds of other round work piece diameters.
-
Product
Safety Laser Scanner Type 3
SD3-A1
-
Panasonic Industrial Devices Sales Company of America
The Panasonic SD3 Safety Laser Scanner is a cost-effective alternative for guarding danger zones. It can be used flexibly in confined spaces and for areas where the danger zone changes.The SD3 can monitor an area within an angle of up to 190° and divides it into 2 zones: a warning zone within a radius of 15m, and a protection zone within a radius of 4m. The contours of these zones can be configured precisely for any application. Up to eight zone patterns can be set and activated at any given time even during operation.The reference boundary function memorizes the position of stationary objects and establishes a virtual boundary. It also monitors beam alignment after installation and issues an alarm if a beam becomes misaligned.
-
Product
For Detecting Low Range And Leakage AC/DC/Pulsed Current.
FDAZCT-20LSP-0.3S
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Lowest Influence from Magnetization,Temperature *Change,Residual Current and Terrestrial Magnetism.*Low Cost and High Performance (Output Linearity ±1% F.S)
-
Product
2D-3D Laser Measurement
-
Long range profiling laser displacement sensor is built to satisfy the most demanding automated dimension, angle, curvature and height in the industrial application. At a fast speed of 6,000 frames per second and up to 2.5µm resolution, it also has measuring of up to 800 mm.
-
Product
Laser Range Finder
-
Shenzhen Noyafa Electronic CO.,LTD
For more than a decade Noyafa has been engaged in researching, developing, and producing high-quality, affordable laser distance meters & rangefinders. Its laser measurer products offer higher accuracy, better target acquisition and higher range resolution. Their capabilities go far beyond just measuring a range. You can instantly measure slope distance, inclination and azimuth and calculate horizontal and vertical distance - all with a single push of a button.
-
Product
4 Channel 24.5~ 29.0 Gb/s Pulse Pattern Generator and Error Detector
CA9808
-
The UC INSTRUEMNTS CA9808 4 Channel 24.5 ~ 29.0 Gb/s (100Gb/s) Pulse Pattern Generator and Error Detector is a high performance, flexible and cost effective four channel Pulse Pattern Generator and Error Detector that can operate from 24.5 Gb/s to 29 Gb/s each Channel. 4 channel 29.0 Gb/s make it total up to over more than 100 Gb/s testing capacity. It is also a standalone Bit Error Rate test solution that incorporates an internal full rate clock synthesizer.
-
Product
Hydraulic Pulse Fatigue Testing System
PFT-500
-
Jinan Testing Equipment IE Corporation
PFT-500 hydraulic pulse fatigue testing machine is mainly applicableto large size parts such as bridges, trusses, automotive chassis, front and rear axels, locomotive frames, chassis and various concrete structures for static compression test and dynamic unidirectional pulse fatigue tests. The Fatigue Testing System for Rail has significant characteristics of reliable design, simple operation, energy conservation, and low operation cost etc.
-
Product
Flex Power Pistol Grip Non Shut-Off Pulse Tools
-
The non shut-off pistol grip pulse tools are ideal selection when the operator needs to control the fastening process. The pistol grip models are commonly used for vertical operations. Designed for safe, reaction free operation for various industrial assembly applications. The FlexPower Pulse Tools provide operators with an industry leading power-to-weight ratio, allowing for a smaller tool selection for greater torques giving operators a lighter tool with more torque capability. Ergonomically safer than harmful hammering and vibration of impact wrenches. Built for durability with a superior O-ring design and specially designed pulse fluid FlexPower extends life between regular oil changes and provides more torque stability. Offers comfortable rubberized non-slip grips for easy handling and excellent thermal ergonomics. Low noise decibels, minimal vibration and low torque reaction. It is important to understand your joint application before a selecting a pulse tool.
-
Product
Laser Source
-
Is an Amplified Spontaneous Emission (ASE) based broadband light source, designed for general laboratory applications. It is a reliable and cost-effective unit that can be ordered with multi channel options. The LD operating temperature and drive current are precisely monitored by a micro-controller to ensure constant output power and emission wavelength stability. With compact size configuration, it’s also suitable for OEM integration, User can control the ASE source output power level by adjusting the drive current along with remote status monitoring, contact Optilab for more information.
-
Product
Extra Narrow Linewidth ECL Laser Module
NLTLS-XXXX-XX-PS
-
Narrow Linewidth ECL Laser Module series are high performance and industry-proven single frequency External Cavity Lasers (ECL) based on
-
Product
Multiphoton Laser Scanning Microscope
FVMPE-RS
-
The Olympus FVMPE-RS multiphoton imaging system is purpose-built for deep imaging in biological tissue, aimed at revealing both detail and dynamics. Innovative features for efficient delivery and detection of photons in scattering media enable high signal-to-noise ratio acquisition. This translates to bright images with precise details — even from deep within the specimen. High sensitivity is matched with high-speed imaging to capture rapid in vivo responses. For advanced applications, dual-wavelength excitation extending to 1300 nm is available. Independent control of visible or multiphoton laser light stimulation and the ability to synchronize with patch clamp data are also possible.
-
Product
1U, Rack Mount, Pulse Distribution amplifier
A5000P
-
The Quartzlock A5000P is a 1U, rack mount, pulse distribution amplifier
-
Product
Laser Spectrum Analyzer
771 Series
-
The 771 Series Laser Spectrum Analyzer from Bristol Instruments combines proven Michelson interferometer technology with fast Fourier transform analysis resulting in a unique instrument that operates as both a high-resolution spectrum analyzer and a high-accuracy wavelength meter. With spectral resolution up to 2 GHz, wavelength accuracy as high as ± 0.2 parts per million, and an optical rejection ratio of more than 40 dB, the model 771 provides the most detailed information about a laser’s spectral properties.
-
Product
High Voltage 50 Ω Pulse Generator
TLP-8010C
-
High Power Pulse Instruments GmbH
*Wafer and package level TLP/VF-TLP/HMM testing*Combines TLP-8010A and TLP-4010C into one system*Can be operated together with TLP-8012A5 and TLP-3011C pulse width extenders*Ultra fast 50 Ω high voltage pulse output with typical rise time 100 ps (0-40 A) and 300 ps (> 40 A)*Up to 80 kW peak output power into 50 Ω load*Built-in HMM pulse up to ±15 kV with 50 Ω configuration*High pulse output current up to ±80 A (short circuit) with minimum 6 dB reflection suppression*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 GPIB programmable pulse rise times: 100 ps to 50 ns*8 programmable pulse widths: 1 ns to 100 ns (0-40 A), 1 built-in pulse width: 100 ns (> 40 A)*The optional pulse width extender TLP-3011C enables pulse width up to 1.6 µs in 68 GPIB programmable steps (0-40 A)*Optional external pulse width extensions from 5 ns to 500 ns (> 40…80 A) using the external pulse width extender TLP-8012A5*Built-in pulse reflection suppression*Fast measurement time, typically less than 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurements of complete wafers*High performance and high quality components