Filter Results By:
Products
Applications
Manufacturers
RF Sources
Produce Radio Frequency (RF) signal.
- Pickering Interfaces Inc.
product
PXI/PXIe RF Switch, 8xSP4T + 4xSP4T, 1.3 GHz, 50 Ω, Multiway Connectors
42-755A-902
The 40-755A-902 (PXI) and 42-755A-902 (PXIe) are high density RF switch modules configured as 8xSP4T and 4xSPDT. The range of modules is available in 50 Ω and 75 Ω variants with mixed SP4T & SPDT switches in a single PXI module. They are available with two connector options; SMB that provides a frequency range of 1.8 GHz (50 Ω) / 1.3 GHz (75 Ω), or multiway which limits the bandwidth to 1.3 GHz but offers a high density solution occupying one PXI slot. The connectors used are fully supported by the range of Pickering Interfaces connection solutions.
-
product
PXI-2597, 26.5 GHz, 50 Ω, 6x1 (SP6T) Terminated PXI RF Multiplexer Switch Module
778572-97
26.5 GHz, 50 Ω, 6x1 (SP6T) Terminated PXI RF Multiplexer Switch Module—The PXI‑2597 is ideal for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules. The internal termination of the PXI‑2597 helps prevent high-power reflections that arise from open channels on the module. You can use the PXI‑2597 onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
product
Ancillaries - Radiated
EMC emissions can be at very low signal levels and pre-amplifiers can help to improve S/N ratio. The low level of emission signals can make them difficult to identify in noisy environments. RF filters are designed to attenuate the major sources of noise, thus making the task of measurement easier.
-
product
4-in-1 OSLT Calibration Kit, DC to 26.5 GHz, Type-3.5 mm (m) 50 Ohm
CK520A
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
product
Planar Doped Barrier Detectors
KRYTAR Planar Doped Barrier Detectors are specifically designed for use in today's high-performance microwave instrumentation and systems. KRYTAR detectors are designed for such applications as power measurements, analyzing radar performance, leveling pulsed signal sources, AM noise measurements, system monitoring and pulsed RF measurements in ultra-broadband and mm-Wave applications.
-
product
Near Field Probes 30 MHz up to 3 GHz
RF2 set
The RF2 near field probe set consists of 4 passive near field probes for measurements in the development phase of the magnetic field in the range from 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF2 set allow the step by step localization of interference sources of the RF magnetic field on assemblies. From greater distances the electromagnetic interference can be detected by RF-R 400-1 and RF-R 50-1 probes. The RF-B 3-2 and RF-U 5-2 probes with their higher resolution can more precisely detect the interference sources. Field orientation and field distribution on an electronic assembly can be detected through a trained special use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.
-
product
All-In-One Infotainment RF Signal Source
AST-1000
The software-defined AST-1000 is powered by Averna’s RF and test expertise, enabling you to generate all common radio signals (e.g., AM/FM, HD Radio and Sirius/XM), digital video signals (e.g., ATSC, CMMB and DVB-T2), and simulate all common GNSS signals (e.g., BeiDou, Galileo and GPS).
-
product
Level System
Universal II
The Universal II level transmitter offers increased reliability, low maintenance and an intrinsically safe design for dependable level measurements in all kinds of process liquids, slurries, granulars and interfaces.Universal IIThe Universal II is a two wire level transmitter that eliminates the need for line power in the field and saves costs for additional hardware. It provides reliable level measurements in all kinds of process liquids, slurries, granulars and interfaces.When powered from an approved source this level transmitter can be made intrinsically safe. Its rugged contruction resists corrosion and abraision. The no moving parts design eliminates break downs.The Universal II level transmitter utilizes RF Admittance technology with manual calibration and a 4 – 20 mA output signal. The patented Cote-Shield circuitry ensures accuracy and reliability regardless of product build-up on the level transmitter.This level system is unaffected by changes in the process material density, pressure, or temperature variations.
-
product
FPGA Mezzanine Card
FMC165
The FMC165 provides two 14-bit analog-to-digital (A/D) channels supporting RF sampling at 2.6 GSPS and one 14-bit digital-to-analog (D/A) channel with sampling rates up to 5.2 GSPS (2.6 GSPS direct RF synthesis). The converters are clocked by either an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. In addition, a trigger input for customized sampling control is available to users.
-
product
PXI-2799, 40 GHz, 50 Ω, Dual SPDT PXI RF Relay Module
782359-01
40 GHz, 50 Ω, Dual SPDT PXI RF Relay Module - The PXI‑2799 is a general-purpose single‑pole double‑throw (SPDT) switch module for routing RF or microwave signals in automated test applications. You can use this module for basic signal routing or inserting and removing components in a signal path. The PXI‑2799 is also well-suited for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules. You can use its onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
product
PXI-2798, 40 GHz, Dual-Transfer PXI Transfer Switch Module
782358-01
40 GHz, Dual-Transfer PXI Transfer Switch Module—The PXI‑2798 can route RF or microwave signals in automated test applications. Designed to operate with less than 1 dB insertion loss at up to 40 GHz, the PXI‑2798 appears almost invisible to signals at much lower frequencies as well. You can use this module for basic signal routing or inserting and removing components in a signal path. The PXI‑2798 is also well-suited for passing high-order harmonics from RF upconverters or routing multiple sources to RF downconverters.
-
product
Multi-Channel Signal Generator
IZT S1000
The IZT S1000 Complex Digital Signal Generator is the perfect source of today's RF waveforms with increasing complexity and bandwidth.One Unit 31 Signal Generators. The IZT S1000 combines most advanced digital signal processing with state-of-the art analog performance.
-
product
Low Noise Pre-Amplifiers
Low Noise Pre-Amplifier and companion external low noise amplifier (LNA) are used to amplify low level microwave signals. The Pre-Amplifier contains an AC/DC power supply, internal low noise amplifier, and a bias tee to source a DC bias voltage on the RF input connector.To overcome cable loss between the test antenna and the Pre-Amplifier assembly, a remote low noise amplifier (LNA) is mounted directly onto the 10 GHz antenna. A bias tee inside the Pre-Amplifier chassis powers the remote LNA through the coax cable interconnecting the pre-amplifier and the 10 GHz test antenna.
-
product
Filtered DC Interface Module
DC modules for RF Test Enclosures eliminate conducted and radiated interference, while providing a source of DC power.
-
product
4-in-1 OSLT Calibration Kit, DC to 50 GHz, 2.4 mm (m)
CK564A
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
product
Frequency Shaped Isotropic Electric Probes
PI-SH-FCC, PI-SH-ICNIRP
An isotropic electric field probe with shaped frequency response meeting the ICNIRP or FCC RF safety standards for occupational and general public exposure limits (see the specified frequency ranges below). Meter readings are shown in % of the STD – standard reference level, eliminating the need to know the source frequency. Probe output is proportional to RF power density in the whole specified power range, producing the correct RF power measurements in single and multi-signal environments, typically present at multiple antenna sites.
-
product
RF Reference Source
96040A Series
The 96040A RF Reference Source enables you to simplify your RF calibration system by replacing many of the instruments and accessories that make up your current system.
-
product
PXI-2554, 2.5 GHz, 75 Ω, 4x1 PXI RF Multiplexer Switch Module
778572-54
2.5 GHz, 75 Ω, 4x1 PXI RF Multiplexer Switch Module—The PXI‑2554 is ideal for use in video RF applications where high-frequency video signal reflections can damage the source. The module also features excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use the onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
product
20 GHz Signal Source
VCO Series
The SC5510A and SC5511A are VCO-based, synthesized signal sources with very low phase noise and an amplitude control of 0.01 dB throughout its -30 dBm to +15 dBm output power range. By utilizing a unique multiple phase-locked loop architecture, phase spurs are kept below -70 dBc across the entire tuning range, even at 1 Hz step resolution. Download the data sheet to see how the impressive features and specifications of these modules make them stand out when compared to other small modular synthesizers. These 20 GHz signal sources include an additional, independent RF2 channel with a tunable frequency range from 100 MHz to 3 GHz and a tuning resolution of 25 MHz. The extra channel makes the modules suitable for either single-stage RF conversion systems or dual-stage image suppression up/down converter systems. Both modules make great general-purpose laboratory signal sources where demanding low phase noise and signal purity are required. They are both ideal choices as an integrated clock source for fast DAC and ADC applications, especially those that require variable sampling rates. Full implementation instructions, GUI, driver software, and example code are provided with each module.
-
product
Concurrent Alternative RF & GNSS Signal Simulation
SimAltNav Replay
Non-GNSS sources of RF (radio frequency) are of interest in GPS-degraded or contested signal environments, with interest focused on LEO (low earth orbit) constellations. These systems offer high receiver signal power (relative to GNSS) and a secure & resilient link to augment GNSS.
-
product
Monics® SatID®
Kratos Defense & Security Solutions, Inc.
Kratos’ leading RF interference geolocation product, satID® provides an accurate, fast, all-in-one solution for locating and identifying sources of interference, including VSAT/TDMA terminals. With the capability to geolocate within 5 km of the interfering signal, satID is the most accurate geolocation product available today.
-
product
PXI-2599, 26.5 GHz, 50 Ω, Dual SPDT PXI RF Relay Module
778572-99
26.5 GHz, 50 Ω, Dual SPDT PXI RF Relay Module - The PXI‑2599 is a general-purpose single‑pole double‑throw (SPDT) switch module for routing RF or microwave signals in automated test applications. You can use this module for basic signal routing or inserting and removing components in a signal path. The PXI‑2599 is also well-suited for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules. You can use its onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
product
Integrated 5G mmWave Test System
IQgig-5G
The IQgig-5G is a fully-integrated, non-signaling solution for testing 5G mmWave products at both the 28 GHz and 39 GHz frequency bands. All signal generation, analysis, and RF front-end routing hardware are self-contained inside a single chassis. The IQgig-5G is license-upgradeable to support the pre-5G and 3GPP standards evolution with up to 1 GHz of tester bandwidth. The IQgig-5G solution has three bi-directional source and measurement ports each with 2.92mm connector coaxial interface.
-
product
RF Safety Monitoring
fieldSENSE 2.0
LBA's FieldSense 2.0 personal RF safety monitors are an effective and economical means to monitor the strength of electromagnetic (RF) fields from wireless cell phone towers, microwave ovens, television stations, and other common workplace RF sources between 50 and 6000 MHz, E-field and H-field (sensed as a plane wave). The Personal RF Monitor is essential RF safety equipment in complying with FCC, OSHA, Canadian and other workplace rf safety requirements.
-
product
MOD MONITOR
TYPE HFX-1
The Type HFX-1 Modulation Monitor is an ancillary piece of equipment, which is used with narrow bandwidth, or older oscilloscopes to allow viewing of RF signals and particularly modulated signals as high as 55MHz. The equipment contains an RF signal source and a broadband mixing circuit which converts the high frequency signal to an intermediate frequency within the oscilloscope’s range. The frequency control dial is simply adjusted until the RF signal is viewed on the scope. BNC connectors are mounted on the rear panel to allow interconnect to the scope and RF probe. This product was previously called "oscilloscope frequency extender" and may be used to view other high frequency signals on older or narrow band scopes.
-
product
Zero Bias Schottky Detectors
KRYTAR Zero Bias Schottky Detectors are specifically designed for use in today's high-performance microwave instrumentation and systems. KRYTAR detectors are designed for such applications as power measurements, analyzing radar performance, leveling pulsed signal sources, AM noise measurements, system monitoring and pulsed RF measurements in ultra-broadband and mm-Wave applications.
-
product
Multi-Channel Signal Generator
S1000 & IZT S1010
One Unit - 31 Signal Generators. Multi-Channel Signal Generator for I/Q data, Sirius, XM, HD Radio, AM, FM, DAB/+, DVB-T and DRM/+. The IZT S1000 Signal Generator Platform enables the user to consolidate multiple conventional RF generators into one compact, cost effective, flexible, and easy-to-use RF test source.
-
product
Active Differential Probe, 100 kHz to 12 GHz
U1818B
The Keysight U1818B 100 kHz to 12 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818B allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.
-
product
Filtered AC Interface Module
AC modules for RF Test Enclosures eliminate conducted and radiated interference, while providing a source of AC power.
-
product
PXI-2545, 2.7 GHz, 50 Ω, Terminated 4x1 PXI RF Multiplexer Switch Module
778572-45
2.7 GHz, 50 Ω, Terminated 4x1 PXI RF Multiplexer Switch Module—The PXI‑2545 is an RF signal multiplexer switch module. The internal termination of the PXI‑2545, which helps prevent high-power reflections that arise from open channels on the module, makes it ideal for use in RF applications where such reflections can damage the source. The module also provides excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use the onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.