Dense Wavelength Division Multiplexing
Dense Wavelength Division Multiplexing
-
Product
PXI/PXIe MEMS Optical MUX, 4-Channel, Single-Mode, 9/125 Fiber, LC Connectors
42-850A-414
Multiplexer Module
The 40/42-850A-414 is a PXI/PXIe 4-channel multiplexer with LC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules.
-
Product
PXI High Density MUX BRIC, 10-Chan, 80-Pole
40-570-115
Multiplexer Module
This range of High-Density Multiplexer is part of our BRIC family. These MUX's are designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is also possible, without limitation). These multiplexers are ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. They are available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts. All version are supported in a BRIC8 construction that occupies eight PXI 3U mechanical slots, one of which provides the PXI interface and power.
-
Product
PXI 2A Multiplexer, 2-Bank, 4-Channel, 16-Pole
40-614C-014
Multiplexer Module
This 2-bank, 4-channel, 16 pole version is part of the 40-614C High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP4T, 18 GHz, 50 Ω, SMA, Terminated, Remote Mount, Failsafe
42-785C-421-TE
Multiplexer Module
The 40-785C-421-TE (PXI) and 42-785C-421-TE (PXIe) are single failsafe SP4T 18 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 67GHz, 50Ω, SMA-1.85
40-785C-572
Multiplexer Module
The 40-785C-572 (PXI) and 42-785C-572 (PXIe) are dual SP6T 67GHz unterminated microwave multiplexers. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
LXI Microwave Multiplexer, 50Ω 6-Channel 7-Bank 18GHz SMA
60-801-207
Multiplexer Module
The 60-801-207 is a 6-channel, 7-bank RF multiplexer suitable for switching 50Ω signals up to 18GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
LXI Microwave Multiplexer, 50Ω 4-Channel 12-Bank 40GHz SMA-2.9
60-802-412
Multiplexer Module
The 60-802-412 is a 4-channel, 12-bank RF multiplexer suitable for switching 50Ω signals up to 40GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI High Density MUX BRIC, 6-Chan, 160-Pole
40-570-016
Multiplexer Module
This range of High-Density Multiplexer is part of our BRIC family. These MUX's are designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is also possible, without limitation). These multiplexers are ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. They are available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts. All version are supported in a BRIC8 construction that occupies eight PXI 3U mechanical slots, one of which provides the PXI interface and power.
-
Product
PXI/PXIe MEMS Optical MUX, 4-Channel, Single-Mode, 9/125 Fiber, FC/PC Connectors
40-850A-114
Multiplexer Module
The 40/42-850A-114 is a PXI/PXIe 4-channel multiplexer with FC/PC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
Product
LXI Microwave Multiplexer, 50Ω 4-Channel 6-Bank 6GHz SMA
60-802-006
Multiplexer Module
The 60-802-006 is a 4-channel, 6-bank RF multiplexer suitable for switching 50Ω signals up to 6GHz. It is part of a range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for between 1 and 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI High Density Multiplexer, 2-Bank, 32-Channel, 2-Pole
40-610A-007
Multiplexer Module
The 40-610A-007 is a 2-bank, 32-channel, 2-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. The range includes a wide choice of switching configurations which are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
PXI 8-slot BRIC Multiplexer, 4-Channel, 160-Pole (6 Sub-cards)
40-570A-014
Multiplexer Module
The 40-570A-014 is a 4-channel, 160-pole High-Density Multiplexer and is part of our BRIC family. The 40-570A range is designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing.
-
Product
PXI 36 Channel Data Comms MUX, 96-pin SCSI
40-735-912
Multiplexer Module
The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. This 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.
-
Product
PXI MUX 1 Bank, 64 Channel Screened 1 Pole
40-610-021-S-1/64/1
Multiplexer Module
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
PXI RF Multiplexer, 4x SP4T, 1.3 GHz 75 Ω, SMB Connectors
40-755-304
Multiplexer Module
The 40-755-304 is a 5xSP4T 75 Ω multiplexer and is part of a range of high density RF multiplexers available in 50 Ω and 75 Ω variants with up to 10xSP4T switches in a single PXI module. They are available with two connector options; SMB that provides a frequency range of 1.8 GHz (50 Ω) / 1.3 GHz (75 Ω), or multiway which limits the bandwidth to 1.3 GHz but offers a high density solution occupying one PXI slot.
-
Product
PXI-2576, 64‐Channel, 2-Wire, Multibank PXI Multiplexer Switch Module
778572-76
Multiplexer Module
64‐Channel, 2-Wire, Multibank PXI Multiplexer Switch Module —The PXI‑2576 is a multibank PXI multiplexer switch module with 16 banks of 4x1 2‑wire multiplexers. With the flexible architecture of the PXI‐2576, you can configure it in a variety of topologies that make it suitable for parallel measurement operations requiring low‐channel counts, or you can combine all multiplexer banks to form a single high‐channel‐count multiplexer featuring 64 2‑wire channels. It also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
Product
PXI/PXIe MEMS Optical Switch, Dual Insert/Bypass, Multi-Mode
40-860A-522-M-HI
Multiplexer Module
The 40/42-860A-522-M-HI is a PXI/PXIe dual insert/bypass switch with ST connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
LXI Microwave Multiplexer, SP4T, 4-Bank, 26.5GHz, 50Ω, SMA
60-803-304
Multiplexer Module
Our 60-803-304 is a 4 bank terminated SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 26.5GHz. The 60-803 range is capable of supporting up to 14 banks of terminated 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI/PXIe Microwave Multiplexer, Triple SP6T, 18GHz, 50Ω, SMA
40-784B-023
Multiplexer Module
The 40-784B-023 (PXI) and 42-784B-023 (PXIe) are triple SP6T 18GHz unterminated microwave multiplexers. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP6T, 3GHz, 50Ω, N-Type, Terminated, Remote Mount
40-785C-561-TE
Multiplexer Module
The 40-785C-561-TE (PXI) and 42-785C-561-TE (PXIe) are single SP6T 3GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
PXI/PXIe MEMS Optical MUX, 8-Channel, Single-Mode
40-852A-018
Multiplexer Module
The 40/42-852A-018 is a PXI/PXIe 8-channel multiplexer with FC/APC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
LXI 8:1 Optical MUX LC Loop-Thru
60-850-421
Multiplexer Module
The 60-850 and 60-851 are LXI conformant fiber optic multiplexers that use MEMS switching technology to ensure fast and reliable switching of single-mode (60-850) or multi-mode (60-851) optical signals being carried on fiber connections. The 60-850/851 is available with a variety of connector options and in a variety of multiplexer arrangements. Loop-thru versions are also available for easy multiplexer expansion.
-
Product
LXI Microwave Multiplexer, SP6T, 2-Bank, 50GHz, 50Ω, SMA-2.4, Terminated
60-800-702
Microwave Multiplexer
High performance RF multiplexer suitable for switching microwave signals up to 50GHz with automatic termination of unused signals
-
Product
LXI Microwave Multiplexer, SP6T, 13-Bank, 50GHz, 50Ω, SMA-2.4, Terminated
60-800-713
Microwave Multiplexer
High performance RF multiplexer suitable for switching microwave signals up to 50GHz with automatic termination of unused signals
-
Product
PXI Multiplexer Dual 24 Ch 1 Pole
40-632-021-D/24/1
Multiplexer Module
This series of general purpose multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 68-pin connector. Available reed relay formats are 1-pole, 2-pole, 4-pole and 1-pole screened.
-
Product
PXI 2 Amp Multiplexer, Dual 16-Channel, 2-Pole
40-635A-006
Multiplexer Module
The 40-635A-006 is a dual 16-channel, 2-pole MUX and is part of a range of Multiplexer modules available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
PXI Dual 4 to 1 RF Multiplexer 2GHz 75 Ohm SMZ/Type 43
40-746-711
Multiplexer Module
40-740, 40-745 and 40-746 RF Multiplexers are a range of Bi-Directional Multiplexers with bandwidth up to 2000MHz. They are arranged as Single 8 to 1, Dual 4 to 1 or Single 4 to 1 configurations, all with excellent Insertion Loss, VSWR and Isolation, in 50 Ohm or 75 Ohm versions with a wide choice of connectors.
-
Product
PXI/PXIe High Voltage Multiplexer, Quad 11-Channel, 2-Pole
40-321-126-HI
Multiplexer Module
The 40-321-126-HI (PXI) and 42-321-126-HI (PXIe) are quad 11-channel 2-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
Product
PXI-2593, 500 MHz, 50 Ω PXI RF Multiplexer Switch Module
778793-01
Multiplexer Module
500 MHz, 50 Ω PXI RF Multiplexer Switch Module—The PXI‑2593 can be programmatically configured as unterminated multiplexers, externally terminated multiplexers, or dimensionally flexible sparse matrices.
-
Product
PXI 5A MUX, 2-Bank, 24-Chan, Ind. Isolation
40-651-102
Multiplexer Module
This range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats: 1-bank 48-channel. 2-bank 24-channel. 4-bank 11-channel. 8-bank 5-channel. Connections are made via a front panel 50-way male D-type connector. Power multiplexer modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.