Frequency Standards
Devices that produce a known frequency.
See Also: Hydrogen Frequency Standards, Rubidium Standards, GPS Clocks
-
Product
Time & Frequency System
TM-4M
-
The TM-4M Time & Frequency System features a larger, easier to use form-factor. It was designed for mobile applications that require uninterruptible power, and for applications that require multiple front panel connections. The six BNC jacks on the front panel are user-assignable to output any signal the user chooses.
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2G30
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Wireless Connectivity Digital Multimeter 6000 Count / NCV / SPT / Wide Frequency
MS-WP6DMM1
-
This is a compact, slim, light weight, pocket size external wireless connectivity Digital Multimeter integrated with 6000 Count, True RMS auto and manual measurement.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1B-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Frequency Converter
-
Our frequency converters, which we offer with outputs of up to 500 kVA, can be used to supply alternating current consumers with constant voltages that deviate from the input network.
-
Product
Standard 1.63 (46.00) - 4.50 (128.00) Battery Probe
CP-059-19
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 62Full Travel (mm): 1.57Recommended Travel (mil): 40Recommended Travel (mm): 1.02Mechanical Life (no of cyles): 100,000Overall Length (mil): 276Overall Length (mm): 7.01
-
Product
Universal Frequency Counter LXI, GPIB
53220A
-
For fast and accurate frequency and time-interval measurements, you need reliable devices in research and development. The Keysight 53220 universal frequency counter meets the requirements for this with its high accuracy, bandwidth and speed. Depending on the application and budget, choose one of the three available models. The connection to the PC is via USB, Ethernet/LXI or via GPIB.
-
Product
Charge Coupled Device (CCD) Standard Image Sensors
-
Teledyne e2v is the leading supplier of scientific grade Charge Coupled Device (CCD) image sensors for the most challenging low light imaging and spectroscopy applications.
-
Product
Radio Frequency Scoring Tool
RFST
-
The Radio Frequency (RF) Scoring Tool (RFST) takes the guess work out of RF environment simulation. During RF environment simulation, the RFST provides clear persistent scoring and recording of the RF simulator’s performance. The RFST digitizes all RF signals in the form of digital Pulse Descriptor Words (PDWs) and associated In-phase/Quadrature (I-Q) data. This massive data stream is recorded for later (Post-Scenario) Analysis. Additionally, the RFST provides a real-time visual display of the accuracy of the RF output, easily visible through straight forward real-time indicators. The post analysis tool set allows an unlimited number of users to simultaneously assess previous RF simulator performance with compelling visual representations. The RFST is a perfect complement to our A2PATS product line offering everything you need for comprehensive environment simulation and analysis.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1UN-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Frequency Counter
FC-2500A
-
High sensitivity for the VHF & UHFfrequency measurement, useful for theCB amateur.* Handheld & pocket size instrument.* Wide measuring range up to 2.6 GHz.* Good resolution, 0.1 Hz min. displayunit for 10 MHz range.* Used the exclusive Microprocessor ICoffered the intelligent function:Frequency, Period, Multi resolution,Data hold, Relative measurement, Datarecord( Max., Min., Average reading).* Auto power off & manual power off.* LCD display for low powerconsumption & clear read-out even inbright ambient light condition.
-
Product
PXIe Frequency Reference: 10 MHz And 100 MHz
M9300A
Signal Generator
The M9300A PXIe frequency reference is a PXIe-compatible, compact, modular instrument that can be used with the Keysight M9301A synthesizer, M9310A source output, and M9311A modulator to create the world’s fastest vector signal generator, the M9381A. Create a CW source, the M9380A, by combining the M9300A with the M9301A and M9310A or use it as the 10-MHz or 100-MHz reference with other PXI solutions. Control the instrument through a soft front panel and programmatic interfaces tuned to your application development environment of choice.
-
Product
Sample Support Holder – Standard 1 Cm² / Custom Reaction Area
SSH-1
-
The Sample Support Holder is designed for mounting flat samples in electrochemical cells and defining a controlled exposed area. Manufactured from PTFE, it accommodates samples 0.1–2 mm thick and 12–14.5 mm in diameter, with a standard exposure area of 1 cm².
-
Product
Radio Frequency Probe HCF77205B200G300A
1165637
-
The HCF77205B200G300A Radio Frequency Probe is engineered for precision and reliability, offering unique capabilities for high-performance applications. Designed as a basic contact probe, it performs effectively within a temperature range of -45°C to +200°C, making it versatile for various environments. Its robust construction includes a beryllium copper plunger coated with gold for excellent conductivity, paired with a brass barrel that features a silver plating for enhanced durability.
-
Product
Radio Frequency Probe HF86FAKRAf016G775MCXfF
1142304
-
The HF86FAKRAf016G775MCXfF radio frequency probe is a state-of-the-art component specifically designed for automotive applications. This probe is engineered to provide reliable performance across a wide temperature range of -45°C to +100°C, making it suitable for various automotive environments. With a robust design featuring a coaxial structure, the HF86FAKRA probe ensures precise connectivity and signal integrity, critical for automotive diagnostics and sensor connections.
-
Product
Cup Reduced Concave, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0G12
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
Time And Frequency Meter
-
A high-precision electronic instrument that measures the frequency of periodic signals and the time interval between events.
-
Product
Radio Frequency Probes (Industrial) HF860MMBXf014G530MCXfS
1039120
-
The Radio Frequency Probes (Industrial) HF860MMBXf014G530MCXfS is a high-performance coaxial probe designed for a variety of industrial applications, ensuring reliable and precise measurements. Built for durability, this probe operates efficiently across a wide temperature range of -45°C to +100°C. With a contour that allows for a pitch of 7.00 mm (276 mil), it supports various setups and configurations to meet diverse technical requirements. The advanced design includes a robust spring mechanism that ensures consistent contact, vital for high-frequency applications up to 4 GHz.
-
Product
DOUBLE FREQUENCY DOUBLE VOLTAGE TEST SET
-
International Biological Laboratories
This test set provides a continuously variable output voltage at double frequency to test the insulation between turns of coils, layer to layer, terminals of windings with either uniform or graded insulation and also between the windings and earth, with graded insulation of both Distribution and Power transformers.
-
Product
Standard Version
-
WISE-STACK 200 is Advantech's lightweight and highly available industrial-grade private cloud.
-
Product
Standard Flexiforce Sensors for Force Measurement
FlexiForce
-
FlexiForce force sensors are ultra-thin and flexible printed circuits, which can be easily integrated into force measurement applications. These sensors are available for purchase in our online store.
-
Product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
Product
Standard 1.59 (40.40) - 7.00 (198.50) High Frequency Probe
CSP-30TS-011
High Frequency Probe
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Recommended Travel (mil): 67Recommended Travel (mm): 1.70Full Travel (mil): 100Full Travel (mm): 2.54Overall Length (mil): 1,003Overall Length (mm): 25.48Rec. Mounting Hole Size (mil): 213Rec. Mounting Hole Size (mm): 5.40Test Center (mil): 375Test Center (mm): 9.53
-
Product
130/180 MS/s Dual Channel PXI Express Digitizer for Frequencies up to 175 MHz
PXIe-1803
Digitizer
This 130/180 MS/s Dual Channel PXI Express digitizer provides the best speed and performance available for input frequencies up to 175 MHz.With exceptional signal integrity, high density and modularity, and channel synchronization options, this new digitizer provides massive functionality in a compact form factor.Key features include:Dual 14/16-bit digitizer configurable as separate or fully synchronized channelsWaveform bandwidths of 65-175 MHz (typical)64M words of waveform memory per channelExternal clock input for synchronization up to 180 MHz250 μV Measurement AccuracyNoise Floor and RelativeAccuracy as Precise as 0.006%
-
Product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-2
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4H
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1H-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Standard Helmholtz Coils
-
Helmholtz Coils are ideal for the measurement of Rare Earth (Samarium Cobalt, Neodymium) and Hard Ferrite permanent magnet materials (materials which exhibit a relative straight line demagnetization). Our standard Helmholtz Coils are for use with fluxmeters. The Helmholtz Coil measures the magnet sample as a single magnetic moment provided that the longest dimension of the magnet sample is less than one-third (1/3) the diameter of the coil system. By definition, the magnetic moment per unit volume is the intrinsic magnetization of the sample. With our calibrated Helmholtz Coil and Integrated Fluxmeter – and given the volume of the permanent magnet sample – the intrinsic open circuit operating B (Bdi) can be measured.
-
Product
Temperature Stabilized Resistance Standards
-
Precision electrical reference devices enclosed in temperature-controlled, EMI-protected chambers to deliver highly stable resistance values for calibration laboratories and national measurement institutes.





























