High Definition
1) High Definition 2) Harmonic Distortion
-
Product
Infiniium S-Series High-Definition Oscilloscope: 2 GHz, 4 Analog Plus 16 Digital Channels
MSOS204A
Oscilloscope
2 GHz bandwidth (upgradable)4 analog plus 16 digital channels Capture a longer signal trace with 20 GSa/s max sample rate and 100 Mpts/channel of standard memory Get superior signal integrity with system ENOB of 7.5 bits and 10-bit analog-to-digital converter (ADC)Gain increased usability with the multi-touch supported 15" capacitive touch screen and solid state drive for fast boot and reliability Improve your testing with a wide range of protocol, compliance, and analysis software
-
Product
HPC High Current Probes, 100 – 187 mil (2.54 – 4.75 mm)
HPC
High Current Probe
100 – 187 mil (2.54 – 4.75 mm)
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75R
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
Product
High-Voltage Differential Probe, 70 MHz
N2891A
High Current Probe
Use the N2891A 70-MHz high-voltage differential probe to make safe and accurate floating measurements with an oscilloscope. The N2891A differential probe allows conventional earth-grounded Keysight oscilloscopes to be used for floating signal measurements of up to ±7000 V of differential and common mode voltage.
-
Product
Brute Hight Current Probes
P4301
High Current Probe
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
CP500X, 500 MHz, ±60 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
784253-01
High Current Probe
The CP500X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 1 meter in length. The CP500X attaches to BNC connections on both the signal input and instrument sides.
-
Product
Brute High Current Probe
P4301-1R
High Current Probe
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
High-Voltage Differential Probe, 100 MHz
N2790A
High Current Probe
Use the N2790A 100-MHz high-voltage differential probe to make safe and accurate floating measurements with an oscilloscope. The N2790A probe allows conventional earth-grounded Keysight oscilloscopes to be used for floating signal measurements of up to 1,400 V of differential voltage and 1,000 V of common mode voltage.
-
Product
Rogowski AC Current Probe,30 MHz, 300 A
N7042A
High Current Probe
The Keysight N7042A Rogowski coil current probe measures AC currents up to 300 A, with bandwidth ranging from 9.2 Hz to 30 MHz. The probe has a thin, lightweight, flexible, and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult-to-reach parts and confined spaces of a circuit under test. It can also measure large AC current without an increase in transducer size.
-
Product
Standard - 1.44 (41.00 - 4.50 (128.00) High Current Probe
HCP-13H
High Current Probe
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Brute High Current Probe
P4301-1W
High Current Probe
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
CP400X, 400 MHz, ±60 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
784254-01
High Current Probe
The CP400X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 2 meters in length. The CP400X attaches to BNC connections on both the signal input and instrument sides.
-
Product
CC5002X, 2 MHz, 500 A Current Oscilloscope Probe
786848-01
High Current Probe
The CC5002X, or Hioki 3275, is a clamp-on current probe that offers a wide DC to 2 MHz bandwidth and 500 A of continuous input. It is ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers. The probe requires an external power supply.
-
Product
HPC High Current Probe
HCP-13
High Current Probe
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Ocean State Monitoring System
WaMoS® II
-
is a radar-based, wave and surface current monitoring system that delivers real-time measurements while a vessel is underway, providing germane data to the local operational area. High definition images of wave fields combined with numerical data and intuitive graphical reporting keep the operator well-informed in assessing environmental risk and identifying safe operational windows.
-
Product
Standard 6.20 (175.20) - 8.00 (226.80) High Frequency Probe
CSP-40A-015
High Frequency Probe
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 275 (6.99) including travel of probes
-
Product
Standard - 22.08 (626.00) - 220.80 (6259.60) Godzilla High Current Probe
HC500F
High Current Probe
Current Rating (Amps): 150Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 260Full Travel (mm): 6.60Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,215Overall Length (mm): 81.66
-
Product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L-QG
High Frequency Probe
Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 0.80Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
Product
High Definition Oscilloscope, 200 MHz Bandwidth, 4 Input Channels, 10 GS/s
HDO4024A
Oscilloscope
200 MHz, 10 GS/s, 4 Ch, 12.5 Mpts/Ch 12-bit HD Oscilloscope with 12.1" WXGA Color Display.
-
Product
High-Voltage Differential Probe, 200 MHz
N2805A
High Current Probe
The N2805A is a 200-MHz differential probe designed to provide superior differential signal measurements with long cable length (5 m), making it ideal in an environment where extended cable length is required. The probe offers 50:1 attenuation ratio, allowing it to be used adequately for up to ±100V DC+peakAC of high voltage differential measurements with high CMRR. The differential probe has a differential input resistance of 4 MΩ and low input capacitance of 4 pF to minimize circuit loading. The probe is powered by Keysight’s oscilloscope AutoProbe interface.
-
Product
SHC68-68-RDIO, 68-Pin Male VHDCI to 68-Pin Female D-SUB, Shielded Digital Cable, 1m
191667-01
High Speed Digital Cable
68-Pin Male VHDCI to 68-Pin Female D-SUB, Shielded Digital Cable 1m
-
Product
CC0550X, 50 MHz, 5 Arms Current Oscilloscope Probe
786846-01
High Current Probe
The CC0550X, or Hioki CT6700, is a clamp-on current probe that offers a wide DC to 50 MHz bandwidth and 5 Arms of continuous input. It is ideal for capturing transient current signals from switching power supplies, inverters, and motor … controllers. The probe requires an external power supply.
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75R
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
Product
SHC68-C68-RDIO2, 68-Pin VHDCI Male to 68-Pin VHDCI Male, 80 MHz, Shielded Digital Cable, 1m
156166-01
High Speed Digital Cable
SHC68-C68-RDIO2 Shielded R Series High Speed Digital Male VHDCI Cable, 1m
-
Product
CC15010X, 10 MHz, 150 A Current Oscilloscope Probe
786849-01
High Current Probe
The CC15010X, or Hioki 3274, is a clamp-on current probe that offers a wide DC to 10 MHz bandwidth and 150 A of continuous input. It is ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers. The probe requires an external power supply.
-
Product
RF High Frequency Probes
High Frequency Probe
*Low impedance*High bandwidth up to 20 GHz*Repeatable measurements*Coaxial design*Interchangeable center conductor
-
Product
High Voltage Probe, 100:1, 3.7 KVpk, 500 MHz
10076C
High Current Probe
The Keysight 10076C 3.7 kVpk, 100:1 passive probe gives you the voltage and bandwidth you need for making high-voltage measurements. Its compact design makes it easier to probe today's small power electronics components, and its rugged construction means it can withstand rough handling without breaking.
-
Product
K-50 Series Probes
High Frequency Probe
The K-50 coaxial probe provides an instrumentation-quality interface for broadband R.F. measurements up to 4 GHz. With the K-50 R. F. circuit design, impedance characterization measurements can be performed using it as a Network Analyzer port-extending accessory. Accurate and repeatable small signal and R.F. power (50 Watts) measurements provide consistent and repeatable results.
-
Product
Standard - 1.44 (41.00) - 4.50 (128.00) High Current Probe
HCP-13P
High Current Probe
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02





























