VOC
biochemicals which readily evaporate at room temperature.
See Also: Volatile Organic Compound, Indoor Air Quality
-
product
CO, Alcohol and VOC Gas Sensor Breakout
MiCS5524
Give your next sensor project a nose for gasses with the Adafruit MiCS-5524 Gas Sensor Breakout. This breakout makes it easy to use this nice sensor from SGX Sensortech. The MiCS-5524 is a robust MEMS sensor for indoor carbon monoxide and natural gas leakage detection, it''s suitable also for indoor air quality monitoring; breath checker and early fire detection.
-
product
VOC Emissions Testing for Electronic Equipment
Underwriters Laboratories Inc.
Product emissions testing on electronic equipment, including printers, consumer electronics, information and communications equipment, and appliances.
-
product
Infrared Camera for Methane and VOC Detection
FLIR GF300
The FLIR GF300 detects methane, other hydrocarbon, and volatile organic compounds resulting from the production, transportation, and use of oil and natural gas. This camera can scan large areas and visualize potential gas leaks in real-time, so you can check thousands of components over the course of one survey. Designed with the user in mind, the GF300 is lightweight, offers both a viewfinder and LCD monitor, and has direct access to controls.
-
product
VOC FIXTURE OVER CLAMP ASSEMBLY'S
Test-X VOC Series overclamps are used for testing bare or loaded printed circuit boards with open vias and to minimize board flex.The VOC Series overclamp comes with adjustable delrin pressure fingers, anti-rotating hex nuts, hinge and latching assemblies, mounting instructions and hardware.The VOC Series will accomodate fixtures with dress frames or newer style fixtures using full-size top plates.
-
product
VOC Detectors
The Baseline® VOC-TRAQ® II detector is a handheld VOC sensor designed for ease of use and is an excellent way to monitor and record PID detectable total volatile organic compounds (TVOCs), whether you are an air quality consultant, safety engineer, maintenance manager, or just concerned about TVOCs in your environment. This Baseline VOC detector includes:
-
product
Air Quality
Controlling IAQ is critical to maximizing building performance and occupant health/safety. ACI sensor solutions for IAQ include VOC and PM (volatile organic compound and particulate matter), CO2 with options to fit every application.
-
product
Fault Detection Device in PV String
Hanwa Electronic Ind. Co.,Ltd.
◆Very light and easy to carry.◆Possible to find fault areas that can’t find by Voc.◆Measurement Voc and Vc.◆Possible to check data and record the data using Android.
-
product
Wireless Temperature Monitor
VAT820-CO2 / VAT820-CO2-VOC99
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Indoor air quality monitor :CO2 monitor , indoor air quality including CO2,VOC temperature ,humudity.
-
product
SparkFun Air Quality Sensor
SGP40 (Qwiic)
The SparkFun SGP40 Air Quality Sensor provides a measurement of the quality of the air in your room or house. The SGP40 is based on Sensirion's CMOSens® technology and uses a metal oxide (MOx) sensor with a temperature controlled micro hotplate and provides a humidity-compensated volatile organic compound (VOC) based indoor air quality signal. Both the sensing element and VOC Algorithm feature an unmatched robustness against contaminating gases present in real world applications enabling a unique long term stability as well as low drift and device to device variation.
-
product
Infrared Camera for Methane and VOC Detection
FLIR GF320
The FLIR GF320 detects hydrocarbon and volatile organic compound (VOC) emissions from natural gas production and use. With this optical gas imaging camera, inspectors can check thousands of components and see potential gas leaks in real-time. The GF320 is lightweight, offers both a viewfinder and LCD monitor, and has direct access to controls. Embedded GPS data helps in identifying the precise location of faults and leaks, for faster repairs.
-
product
Indoor Multi-Light source of Measurement System for PV Cell
King Design Industrial Co., Ltd.
The multi-light source measurement system is capable of execute I-V measurements by Real-Time One-Sweep Method (RTOSM), which not only removes the capacity effect but also meets the requirements of SEMI PV57-1214. The measurement process is controlled by designed program, thus the measured I-V curve, Pmax/Isc/Voc/… etc, could be exported automatically.This system is applicable to DSSC/OPV/Perovskite measurements.
-
product
Desktop:Touch Buttons : CO2 Monitor Real-time Monitoring of Indoor Air Quality Including CO2,Temp
VAT810-TH/SD (VAT810-CO2)(VAT866
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Desktop:Touch buttons : CO2 monitor Real-time monitoring of indoor air quality including CO2,temperature ,humudity and VOC.
-
product
Optical Gas Imaging Camera
FLIR GF620
The FLIR GF620 is the first high-resolution, handheld camera from FLIR to detect methane and other volatile organic compound (VOC) emissions. With its ground-breaking 640 x 480 resolution IR detector, inspectors can check thousands of components and safely scan for gases from greater distances. It's also the first FLIR OGI camera to offer Quantification mode (Q-Mode) for streamlined set-up of the optional QL320 gas quantification system.
-
product
Gas & Emissions Analyzer
Si-CA 8500
Accurate, reliable, robust & fast, the Si-CA 8500 Combustion Analyzer is the most powerful and advanced portable emissions analyzer on the market. Complete portable tool for emissions level monitoring of boilers, engines, and other combustion equipment, this emissions monitoring device can boast as many as 9 gas sensors, detecting one of the widest spectra of gases: O2, CO, NO, NO2, SO2, CO2, CxHy, High CO, VOCs and H2S.
-
product
Solar Cell Testers
Solar Cell Testers are integrated systems incorporating Solar Simulator and I-V Measurement systems. PET offers Standard and Advance IV Measurement software. PET Cell Testers are capable of measuring a diverse range of solar cell parameters such as Isc,Voc, Imax,Vmax, Pmax, FF, Rsh, Rs and η cell conversion efficiency, complete light and dark I-V curves. All that needs to be done to test a cell is to load the cell, make electrical probes contact and press “Measure” icon on the I-V Measurement System software. The software will automatically open the Solar Simulator shutter, perform the test and close the shutter after the test is complete. The design is modular in nature and can be easily upgraded. Some options can added at a later time.
-
product
CO2 meter alarm
VAT820-CO2
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Indoor air quality monitor :CO2 monitor , indoor air quality including CO2,VOC temperature ,humudity
-
product
Automated Monitoring of Airborne Molecular Contamination
AMC-Monitor T-1000
The all-in-one analyzer for FOUP, fab and clean-room environment AMC monitoring in the semiconductor industry. The AMC-Monitor is a modular and flexible platform for airborne molecular contaminations (AMC) monitoring in semiconductor applications such as: FOUP analysis with a focus on VOC and condensables incl. full integration with Pfeiffer Vacuum APA 302 pod analyzer. Clean-room monitoring in fabrication plants.
-
product
Air Quality USB Dongle
UTHINGL::VOC
uThing::VOC™ is a USB dongle useful to quickly integrate or evaluate the Bosch BME680 air quality sensor. If you need to sense air-quality data and decide to use the Bosch BME680, you will find that integrating the Bosch proprietary algorithms is not a trivial task, and that the code size limits its use in constrained platforms like many Arduino boards.
-
product
Power Meters and Calibration Cells
The Solar Reference Cell consist of a 20 x 20 mm monocrystalline silicon Photovoltaic Cell encased in a 92 x 70 x 16 mm metal enclosure with a protective quartz window and a temperature sensor. The temperature sensor is a 100 ohm platinum Resistance Temperature Detector (RTD).The Solar Reference Cells come with a Certificate of Calibration and compatible set of connecting cables. The following parameters of the reference cell are certified: Isc, Imax, Voc, Vmax, Pmax, Area, Fill Factor and Efficiency. The certification is accredited by NIST to the ISO-17025 standard and is traceable both to the National Renewable Energy Laboratory (NREL), and to the International System of Units (SI). A compatible cable set is also supplied with each Solar Reference Cell.
-
product
Environment Click
64205
The Environment click module measures temperature, relative humidity, pressure and VOCs (Volatile Organic compounds gases).
-
product
CDPH Standard Method for VOC Emissions
Underwriters Laboratories Inc.
The Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions From Indoor Sources Using Environmental Chambers, an expanded standard for what is commonly known as California Specification 01350, is one of the most widely used standards to evaluate building and interior products for low chemical emissions.
-
product
Sensor Solutions for IoT
Imec is a reference in the design of ultra-low power electronics, low-power algorithms to increase intelligence and data security, and in all aspects of data science. Our multi-sensor environmental monitoring platform features sensors for temperature, relative humidity, NO2, CO2, VOC (volatile organic compounds), particle matter, ambient light, sound, vibrations and presence detection. Our test platform is suitable for indoor and outdoor air quality monitoring and control, and can be used in smart buildings, smart cities and more.
-
product
EQE/Photon-Electron Conversion Testing
Enlitech offers different solutions for incident photon-electron conversion testing systems. The available systems include IPCE, PV External quantum efficiency (PV-EQE), Internal Quantum Efficiency, Spectral Response (SR), Highly-sensitive EL-EQE. There are over 1,000 SCI papers cited Enlitech‘s systems to provide reliable experimental data for significant scientific publication. The Highest PV-EQE sensitivity and EL-EQE both reach 10-5 % (7 orders). They can be utilized to PV conversion efficiency, HJT/ PERC/TOP-CON current-loss analysis, Organic PV charge-transfer-state and Perovskite PV trap state measuring, and Organic PV and Perovskite PV Voc loss analysis.
-
product
Ambient Pressure Photoemission Spectroscopy With Nitrogen Environment
The APS04-N2-RH incorporates a tuneable deep ultra-violet (UV) source outputting 3.4 - 7.0 eV, for absolute work function and highest occupied molecular orbital (HOMO) measurements, a surface photovoltage spectroscopy (SPS) module outputting 400 - 1000 nm for Voc and Eg measurements, together with a 50 x 50 mm scanning area for planar relative work function measurements (Fermi level).
-
product
Gas Analyzers
Omega's Handheld Gas Analyzers are ideal for monitoring VOC levels in petrochemical plants, power plants, mining facilities and restaurants. Models available to measure CH4, CO, O2, and H2S
-
product
Total Hydrocarbon Analyzer
Model 4030
Teledyne Analytical Instruments
The Model 4030 uses a field proven FID detector in a heated chamber. The chamber is heated to a high temperature to meet US EPA requirements for VOC emissions monitoring.
-
product
SparkFun Environmental Sensor
BME688 (Qwiic)
The SparkFun BME688 Environmental Sensor is a breakout that combines a gas scanning sensor with temperature, humidity, and barometric pressure sensing for a complete environmental sensor in a single package. The gas sensor on the BME688 can detect a wide variety of volatile organic compounds (VOCs), volatile sulfur compounds (VSCs), and other gases such as carbon monoxide and hydrogen in the part per billion (ppb) range. Combine that with precise temperature, humidity, and barometric pressure and the BME688 can work as a completely standalone environmental sensor all in a 1in. x 1in. breakout!
-
product
GC Sample Prep & Sample Introduction
For Gas Chromatography Preparation & Introduction, Teledyne LABS’ brand offers Purge & Trap instruments to prepare samples for separation. P&T is routinely applied to detect volatile organic compounds (VOCs) down to sub-ppb levels in soil and water, and as a step in determining outdoor and indoor air quality. The arrival of microprocessor-driven systems allows the concentrator to be more precise and automated, giving the operator more time for other projects. All Teledyne LABS P&T instruments satisfy U.S. Environmental Protection Agency method guidelines.
-
product
Solar Cell Simulation
Setfos
Easily calculate the short circuit current, open circuit voltage Voc and fill factor with Setfos. Tweak the layer stack and add light scattering layers for enhanced absorption. Optimize for AM1.5 or specific wavelength bandsElectrical IV curvesCurve fitting & parameter extractionAC simulation and transient experiments like photo-CELIVAdvanced device physics: SRH-recombination, excitons, ... Design anti-reflection coatings or transparent cells





























