Transformer Test
Measure turns ratio, no-load current and winding resistance of transformers.
See Also: Transformers, Transformer Testers, Current Transformer Test, Current Transformer Test Set
-
product
Three-Phase Transformer Demagnetizer
DEM60C
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.
-
product
Current Transformer
CT
The split-core current transformers are easily installed with the snap on design.
-
product
Current Transformer Tester
CTT
The CTT is designed to test the current transformer ratio, Phase shift, Polarity, Excitation, Saturation, Winding resistance and Insulation resistance using the voltage method in compliance with ANSI/IEEE C57.13.1 and IEC 60044-1 standards, where voltage is applied to the secondary X terminals of the current transformer.
-
product
Current Transformer Analyzer/Tester
GF1061
Beijing GFUVE Electronics Co.,Ltd.
Portable CT PT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to download data or RS232 port to PC control. This model GF1061 CT PT analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE C57.13 and IEC60044 & IEC61869 standards.
-
product
Distribution Transformer Tester
DOC-2000™
The DOC-2000™ is a test instrument designed for distribution networks transformers up to 167KVA. It can determine the presence of short circuits or an open circuit in the distribution transformer primary winding & also short circuits on the secondary winding. The DOC-2000™ is designed to be operated from an arial device or from the ground at the end of a hot stick without disconnecting the transformer’s secondary windings.
-
product
High Current Transformers
High Current Transformer is designed to elevate and check the temperature of the conductors at high current levels, in order to simulate the current loading conditions found in electrical circuits. High Current Transformer is designed as an open type transformer that uses the test object as its secondary coil or has 1 or 2-turn self secondary winding. The conductors cores' temperature depends on the short-circuit high current caused by the test object. According to the current going through the test object, the test temperature of the conductor will change. The loop temperature is measured by a thermocouple probe which is directly connected to conductor.
-
product
Noise Figure Analysis Using NI PXI RF Test Instruments
NI-RFmx Noise Figure
Measure noise figure, gain, Y-factor, effective temperatures, hot and cold power, and moreOptimized calibration and measurement routines for multi-DUT test using Y-factor and cold sourceSupports the PXIe-5668R 26.5 GHz VSA, the PXIe-5698 26.5 GHz preamplifier, and VSTsDesigned for use with industry-standard noise sources such as the Noisecom NC346 Series
-
product
Multiplexer For Transformer Testing
MUX-R
Raytech Multiplexer MUX R is designed to drastically reduce cabling time and increase test performance. It is made to be used with Raytech Winding Resistance and Turns Ratio Meters. Any MUX R configuration can be easily controlled by a Winding Resistance Meter touch panel or by remote.
-
product
Instruments Transformers Tester
Calport 100 Plus
Calmet Smart Calibration Devices
Three phase instrument transformers and electricity meters tester class 0.1 or 0.2. It makes possible CT and PT testing on site or in the laboratory. We recommend a new replacement - TE30 Working Standard
-
product
Automatic Test System
Automatic Test system is the ultimate solution for power electronic testing. The system includes a wide range of hardware choice such as AC/DC Sources, Electronic Loads, DMM, Oscillate Scope, Noise Analyzer and Short /OVP Tester. This flexibility combined with its open architecture software platform-PowerPro III, gives users a flexible, powerful and cost effective test system for almost all types of power supply testing.
-
product
High Voltage Transformer
RR manufactures HIGH VOLTAGE TRANSFORMERS for various Industrial Applications.
-
product
Electronics Functional Test
Functional test for productive manufacturing. Manufacturers of products enabled by electronics must assure proper operation prior to shipment. Bloomy’s line of universal test systems are ideal for functional test of your PCBAs and subassemblies, from the simplest to the most complex. The UTS family of products combines high-performance test instruments, switching, power control and mass-interconnect hardware with our robust UTS software suite into a low-risk, cost-effective and powerful test solution for your device under test (DUT).
-
product
Combined Transformer
Combined Transformer is a great solution for projects with dimension restrictions. Because we focus on quality and reliability of our products our combined transformers also require minimum maintenance once installed.
-
product
Transformer Resistance Testing
Transformer insulation resistance deterioration is one of the most common causes of transformer failure: a failing transformer is a costly replacement in an electrical system with the potential for a long downtime. If you fail to maintain your transformer with regular insulation resistance testing (as can be carried out by the Megger Transformer Ohmmeter (MTO) series of transformer test equipment) then it’s likely to fail before reaching its maximum operating life.
-
product
High Temperature Component Test Fixture
16194A
Measure both axial/radial leaded devices and SMD within the temperature range from -55 to +200°C.
-
product
Injection Transformer
J2100A
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
product
Instrument Transformer Calibrators
CTPT 81
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Tests: Ratio error. Excitation current and curve. Polarity CT / PT TESTER
-
product
PXI Functional Test System
U8989A
The TS-8989 PXI functional test system is an integrated, all in one switch, load and measurement system in a box for high voltage or current mechatronics functional test applications of up to 104 nodes and 40A current loads.
-
product
Isolation Transformers 230V
PeakTech Prüf- und Messtechnik GmbH
Due to the high safety requirements in service workshops, schools and industry, an isolating transformer is an absolute prerequisite for carrying out professional repair work. Galvanic isolation between primary and secondary voltage during measurements and repairs on open devices guarantees a high safety standard for the user. Of course, galvanic isolation from the mains voltage also offers other advantages in electronics development, audio technology and many other areas.
-
product
Current Transformer
ST-60CT
Standard Electric Works Co., Ltd
● 400/5A - 800/5A● 7.5-10V A● Class 1● Insulation 600V
-
product
TD-SCDMA Analysis Using NI PXI RF Test Instruments
NI-RFmx TD-SCDMA
The NI-RFmx TD-SCDMA personality is a highly optimized API for performing physical layer measurements on TD-SCDMA cellular standard signals. NI-RFmx TD-SCDMA is completely interoperable with all NI-RFmx APIs. It provides simple access to the most advanced optimization techniques such as multi-measurement parallelism and multi-DUT measurements. The result is extremely fast and high-quality measurements with minimal software development efforts.
-
product
Power Transformers
Power Transformers are used to convert voltages and isolate signals for functionality and safety. Our broad line of catalog and custom solutions range from mW to 5-10kW and are used in multiple topologies including flyback, forward, push-pull, resonant, LLC and phase shifted full bridges. Typical operating frequencies are between 80-500kHz but solutions can be adapted for greater than 1MHz operation.
-
product
In-Line 2-Module In-Circuit Test System; i337x, Series 5i
E9988EL
The i3070 Series 5i Inline ICT retains the popular and proprietary Keysight short-wire fixturing technology used in our stalwart Keysight 3070 and i3070 systems.
-
product
In-Circuit Test Systems For Sale
Forwessun offers a comprehensive range of global services for a variety of Test Systems. We provide refurbished systems that have undergone rigorous testing, giving you reliable performance at a fraction of the cost of new equipment. Whether you’re looking for a long-term solution to enhance your testing capabilities or a temporary setup to meet increased production demands, we have flexible options to suit your needs. - HP3070- Agilent - Keysight- GenRad- Teradyne Our bespoke rental agreements make it easy to scale up without permanent investment—simply return the system when it’s no longer required. For ongoing support, we offer calibration, repair, and maintenance services through convenient service contracts. If you’re looking to retire any outdated or non-functional In-Circuit Test (ICT) systems, we’ll offer fair market prices, helping you maximise value on any surplus equipment.
-
product
PPS Clamp Transformer
PPS2 provides power supply to the PD detectors installed on HV cable when low voltage AC power is not available. The PPS2 takes the required power directly from the High Voltage power line under monitoring by means of units clamped on the HV power cable(s).PPS2 is designed to withstand High Voltage line failure events such as temporary overload and short circuit conditions. An internal detection and self limiting circuitry guarantees that PPS2 and the connected equipment survives in case of such events.
-
product
Test Fixture
16047E
Perform impedance evaluation of lead type devices of up to 120 MHz; includes a guard and a shorting plate
-
product
Transformer Capacity Tester
Weshine Electric Manufacturing Co., Ltd
In many industries, including health care, manufacturing, electrical contracting, higher education and corrections, reliable, high-quality transformers are essential for keeping operations running efficiently. Large facilities and industrial processes require substantial amounts of power, and they need dependable transformers to convert the energy coming from the power plant into a form they can use for their equipment and building utilities.
-
product
Transformer Winding Resistance Meters
RMO TW Series
The RMO-TW instrument can perform a simple, fast and reliable verification of a transformer on-load tap changer. This instrument allows measurements of a winding resistance at each tapping position of an on-load tap changer without discharging between tests. Problems with OLTC switching, such as interruption, can be detected with these measurements. The results are displayed on a backlit LCD screen.





























