Distortion
See Also: Total Harmonic Distortion, Intermodulation Distortion, Noise, Distortion Analyzers, Distortion Meters, SINAD
-
Product
Intermodulation Distortion Measurements
S96087B
-
Easily set up and calibrate swept intermodulation distortion measurements (IMD) measurements using the S96087B software application with the ENA
-
Product
Fuzz & Distortion Pedals
-
A fuzz pedal takes your sound and clips it extremely hard - known as square-wave clipping - thereby compressing the distortion to make an almost unrecognisable sound.
-
Product
Intermodulation Distortion Measurements For M980xA PXI VNA
S95087B
-
Easily set up and calibrate swept intermodulation distortion measurements (IMD) using the S95087B software application with the M980xA PXI VNA.
-
Product
Modulation Distortion Up To 50 GHz
S930705B
-
S930705B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 50 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930704B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
Product
ACCUplace Dot Distortion Target
AP-DD Series
-
All machine vision lenses will show some type of distortion. Minimizing or correcting that distortion is crucial in most applications. The ACCUplace Dot Distortion target is designed to detect the presence of both barrel/pincushion distortion as well as alignment distortion that causes the keystone effect. The precise amount of distortion is determined from an array of precisely placed dots in a regular array. The results can be used to correct for any distortion that occurs within the optical system. The AP-DD is offered on three standard substrates; Chrome on Glass (CG) Opal (OP) and Photo Paper (RM).
-
Product
Modulation Distortion Up To 43.5 GHz
S930704B
-
S930704B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 43.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930704B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
Product
Intermodulation Distortion Measurements For P50xxA/B Streamline Series VNA
S97087B
-
Easily set up and calibrate swept intermodulation distortion measurements (IMD) measurements using the S97087B software application with the P50xxA/B Streamline Series VNA
-
Product
Modulation Distortion Up To And Beyond 125 GHz
S930713B
-
S930713B enables fast and accurate active-device modulation distortion characterization under modulated stimulus conditions up to and beyond 125 GHz. The wide dynamic range and vector error correction of the PNA-X results in an extremely low residual EVM of the test setup, delivering you a complete picture of your device’s performance without test system interference. S930713B measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
Product
Modulation Distortion Up To 53 GHz
S95070B
-
S95070B software enables fast and accurate active device modulation distortion characterization under modulated stimulus conditions up to 53 GHz. The wide dynamic range and vector error correction of the PXI VNA results in an extremely low residual EVM from the test setup, giving you a complete picture of your device’s performance without test system interference. S95070B software measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals through spectral correlation between the input and output spectrum, without doing demodulation. Integration with the PXI VNA’s measurement flexibility enables you to do quick modulation distortion measurements along with traditional VNA tests.
-
Product
ACCUplace Dot Patterns
AP-D Series
-
All machine vision lenses will show some type of distortion. Minimizing or correcting that distortion is crucial in most applications. The ACCUplace Dot Patterns target is designed to check, verify, or quantify barrel distortion in vision systems, alignment between multiple optical systems, and can calibrate instruments with both vision and motion systems. The indexed columns and rows of dot features provide reference points that make alignment and distortion detection simple and straightforward. The AP-D is offered on four standard materials; Glass (CG) Opal (OP) Photopaper (RM) and Film (TM).
-
Product
Automatic Meter Calibration Console
PMT40600
-
Power Measurement Technologies Inc.
Provides Measurement Canada compliant, fully automated testing of single and polyphase electrical energy and demand meters. Amplifier technology provides stable, low distortion, four-quadrant dynamic loads up to 600VAC and 200 amperes.
-
Product
Selective Level Meter
Model SLM620
-
- Digital Synthesized Local Oscillator- Two Selective Bandwidths : 20Hz, 3.1KHz- Wideband, Low Noise and Low Distortion Measurements- dB/dBm Operation- High Frequency Stability- Internal Calibration Facility- Recorder Outputs- Frequency Tracking Facility with Level Oscillator SLG620- Storage of Nine Spot Frequencies- Reference Level Set Facility- Autotune Feature- Operates on AC Mains or Internal Rechargeable Battery- Built in charger- Graphic LCD Display with Backlight
-
Product
EMC Analyzers
-
Mains and harmonics analyzer and associated low distortion AC power source for EMC measurements to EN61000-3-2 and EN61000-3-3.
-
Product
RF Amplifier
SA1012
-
Hangzhou Softel Optic Co., Ltd.
*Forward path use import low noise push pull amplify module or GaAs push pull module,2 Power-Double module or GaAs amplify module are used as output stage, Output level is stable and nonlinear index is good, import high index amplify module are used on return path, It's distortion is little and SNR is high.*It is more convenient to debug because of plug-in(or adjustable) duplex filters, plug -in fixed(or adjustable)equalizers, plug-in output splitters and scientific and rational on-line detection ports.*The equipment can work steadily outdoor under bad environmental condition because of waterproof aluminum case, high reliability switching power supply and lightning protection system.
-
Product
Modulation Distortion Up To 125 GHz
S930712B
-
S930712B enables fast and accurate active device modulation distortion characterization under modulated stimulus conditions up to 125 GHz. The wide dynamic range and vector error correction of the PNA-X results in an extremely low residual EVM of the test setup, delivering you a complete picture of your device’s performance without test system interference. S93072B measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
Product
Voice Quality Solutions
-
Wireless networks can impair voice, video, and data quality by various means including poor mobile phone quality, voice compression and decompression algorithms, video compression and decompression algorithms, delay, loss or gain in speech levels, noise, acoustic and landline echo, and other distortions. GL provides a compact and portable solution for Wireless Devices, and Mobile Radio testing.
-
Product
Audio Oscillators
-
Frequency Range : 10Hz to 1MHz in 5 Decade Steps Very Low Distortion : <0.5% Output Voltage : 22.6Vp-p Open Circuit Sine Wave and Squre Wave Easily Choice Built-in 4 Digits Frequency Counter with Internal/External Varialble Frequency with Poly Varicon 400Hz and 1kHz Fixed Special Function Compact Design and easy Operation 2. Accessories Spare Fuse : 1EA Operator''s Manual : 1EA Power Cord : 1EA BNC Cable : 1EA
-
Product
Arbitrary Load Control For Modulation Distortion
S94570B
-
Extend the modulation distortion application by computing figure of merits such as EVM and ACPR for any desired load with arbitrary load control (ALC). Modulation distortion with ALC integrates the powerful capabilities of the PNA-X with an electromechanical tuner so a non-50 Ω load can be presented to the DUT and changes in device performance or sensitivity to varying load conditions can be accurately measured.
-
Product
Programmable AC Source
6500
-
Chroma Systems Solutions, Inc.
1200VA ~ 9KVADirect Digital Synthesis (DDS) waveform generationProgrammable voltage, current limit, frequency, phase, and distortion
-
Product
13.56MHz RF Power
-
100 W to 2400 W. 13.56 MHz. Analog/Digital, RS-232, USB interfaces. Low Harmonic Distortion. Automatic and Manual Gain Control. High Speed Pulsing (Bursting) controls. Compatible with T&C's Matching Networks. GUI Software (complete PC control). Includes all essential RF power/communication cables and mounting brackets. Air cooled (Air & Water 1200 W +). Half rack mount or stand alone versions. Ideal for: Industrial, Scientific, and Medical Applications.
-
Product
Wideband Power Amplifiers
-
Krohn-Hite Wideband Power Amplifiers are designed to meet today's industrial needs where wideband, precision performance is required. Applications include: meter calibration, piezo transducer driving, bridging applications requiring high input and low output impedance, low distortion ac power source, ion beam deflection, vacuum tube driver, ink jet testing and design and many more.
-
Product
Audio CODECS
-
Analog Devices has audio codecs for many different applications, such as automotive, home theater, consumer audio, and PCs. ADI’s audio codecs feature extended temperature range, low noise and distortion, and easy multichannel interfacing to common DSPs, such as SHARC® and SigmaDSP™.
-
Product
Difference Amplifiers
-
A difference amplifier is a special purpose amplifier designed to measure differential signals, otherwise known as a subtractor. A key feature of a difference amplifier is its ability to remove unwanted common mode signals, known as common mode rejection (CMR). Unlike most types of amplifiers, difference amplifiers are typically able to measure voltages beyond the supply rails, and are used in applications where large dc or ac common-mode voltages are present. They are ideal for current and voltage monitoring. Analog Devices offers a range of difference amplifiers, optimized for low distortion, low power, or high voltage performance.
-
Product
Attenuators
-
An attenuator is an electronic device that reduces the power of a signal without appreciably distorting its waveform.
-
Product
Moisture Meters
-
Moisture Meters fall into two categories, pin-type and pinless. Pin-type Moisture Meters measure the resistance between test pins inserted into a piece of wood or a building material and use that reading as a proxy for the object''s absolute moisture level. The wetter the material, the less ready it is to be sanded, painted, finished or covered. A best seller is the MMD4E Pin-Type Moisture Meter. Pinless Moisture Meters rely on the ability of moisture to inductively distort an electric field created by turning on the meter. Although Pinless Moisture Meters can only make relative readings, they are nonetheless useful for pinpointing the source of a leak above a ceiling, and for leaving no unsightly pinholes on a finished surface. The MMD7NP is a best selling pinless moisture meter.
-
Product
Air Core Line & Load Reactors
-
Line and load reactors are generally serial-connected to the input and/or output terminals of three phase equipment such as motor speed controllers, inverters and UPS systems. These equipment make use of semiconductor switches such as IGBTs, thyristors, and diodes and therefore create harmonic distortion and high switching over-voltages (dv/dt). Use of such equipment has been becoming more widespread as the technology advances. However, the negative effects of these equipment should not be overlooked.
-
Product
Precision Condenser Microphone
377B11
-
Performance:Nominal Microphone Diameter:1/2 CharacteristicPressureOpen Circuit Sensitivity: 50 mV/Pa50 mV/PaInherent Noise<15 dB(A) re 20 Pa<15 dB(A) re 20 Pa Dynamic Range (3% Distortion Limit)>143 dB re 20 Pa>143 dB re 20 Pa EnvironmentalTemperature Range (Operating)-40 to +248 F-40 to +120 C Temperature Coefficient of Sensitivity (+14 to +122F (-10 to +50C))0.005 dB/F0.009 dB/C
-
Product
RF Front-End ICs
-
Analog Devices offers RF Front-End ICs for phased array antenna solutions. These RF Front-End ICsare placed right at the antenna element and can quickly switch between transmit and receive functions in radar applications. The power amplifier on the transmit side is highly efficient operating in short pulse durations. The low noise amplifier on the receive side has a low noise figure with high linearity so that it won’t distort the incoming return signal. The RF Front-End IC also incorporates a high performance switch to toggle between the transmit and receive paths. Highly integrated planar phased array antennae need small form factor solutions, and Analog Devices has integrated the switch, low noise amplifier, and power amplifier into a small surface mount package as well as the decoupling capacitors, providing an optimal solution.
-
Product
IQ Data Bandwidth Up To 1.5 GHz
S93050B
-
Make multiple measurements of active device distortion analysis with a single connection to a PNA family network analyzer utilizing the industry-standard PathWave 89600 VSA (VSA) software for 5G transmitter test. The VSA IQ data link feature in S93050B allows you to send IQ data from the PNA to the VSA software and analyze symbol EVM, AM-AM, and AM-PM.