Waveform Signal Generators
See Also: Waveform Generators, Arbitrary Waveform Generators
-
product
Alternate 3.20 (90.00) - 6.90 (196.00) General Purpose Probe
EPA-4F-1
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
product
Signal, Contact, Receiver, TriPaddle, 7 Amp, 20-24 AWG, Crimp only
610110101
Primary mating contact 610110108. (May mate with other ITA contacts, as well.)p/n 610110125 TriPaddle Receiver 50µ" AU plating.p/n 610110101 TriPaddle Receiver 30µ" AU plating.Specifications Operating Voltage & Current 7 Amps Max. Continuous (20 AWG)600 Volt Max. use of wire Mil-W-16878/4Contact Resistance 4 mOhms Max.Measured at 50 mV @ 100 mAContact Body BeCuContact Plating 30µ” Au over 100µ” NiContact Termination CrimpCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs.) 0.41
-
product
1.25GS/s 16Bit 1GS Mem 12CH Arbitrary Waveform Generator
P12812B
The Proteus P12812B, is a 1.25GS/s, twelve channel arbitrary waveform generator packaged in a 4U, 19” standalone box with a 9” touch screen and on board PC , offering technologically advanced options and configurations that integrate the ability to transmit, receive and perform digital signal processing all in a single instrument. The P12812B offers industry leading performance Including an innovative task oriented programming, real time data streaming, fast feedback loop for environment dependent waveform generation and user customizable FPGA for application specific solutions.
-
product
Differential Active Probe, 500 MHz
DP0011A
The Keysight DP0011A is the 500 MHz model of the DP001xA Series differential active probes. These probes provide the superior general-purpose differential signal measurements required for many of today’s high-speed power-related measurements such as motor drives, automotive differential bus measurements, and high-speed digital system designs.
-
product
Alternate 2.64 (75.00) - 6.50 (184.00) General Purpose Probe
EPA-2B30-1
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
PCIe 16 Bit Arbitrary Waveform Generator - up to 1.25 GS/s on 2 Channels
M4I.6631-X8
The M4i.66xx-x8 series arbitrary waveform generators (AWG) deliver the highest performance in both speed and resolution. The series includes PCIe cards with either one, two or four synchronous channels. The large onboard memory can be segmented to replay different waveform sequences. The AWG features a PCI Express x8 Gen 2 interface that offers outstanding data streaming performance. The interface and Spectrum’s optimized drivers enable data transfer rates in excess of 2.8 GB/s so that signals can continuously replayed at a high output rate. While the cards have been designed using the latest technology they are still software compatible with the drivers from earlier Spectrum waveform generators. So, existing customers can use the same software they developed for a 10 year old 20 MS/s AWG card and for an M4i series 625 MS/s AWG.
-
product
Vector Signal Transceiver-based Radio Solution (VRS)
ATS-3100 VRS
The ATS-3100 VRS, the newest member of the ATS-3100 PXI Integration Platform product family and fifth-generation radio test solution, is a single, consolidated platform for testing legacy, modern, and next-gen, software-defined radios for military, civil, and commercial users. Integrating the PXI Vector Signal Transceiver (VST) from National Instruments (NI), the platform enables faster test time with wider bandwidth (up to 1GHz) than any other radio test solution available today.
-
product
PXI-5651, 3.3 GHz RF Signal Generator
779670-01
3.3 GHz PXI RF Analog Signal Generator—The PXI‑5651 features continuous-wave generation capabilities with FM, 2‑FSK, or OOK modulation. It uses direct digital synthesis (DDS) for high-resolution frequency hopping or phase-continuous sweeping for fixture and device characterization applications. The PXI‑5651 is ideal for clocking nonstandard sample rates, such as WCDMA signals at baseband or intermediate frequency (IF). With these versatile signal generators, you can perform analog and digital modulation through the onboard DDS circuit, which gives you frequency modulation and frequency-shift keying for applications such as bit error rate test, antenna testing, or even keyless entry. You can also perform amplitude modulation using on-off keying.
-
product
PXIe Microwave Signal Generator
LSX2091X
The LSX2091X is a 20GHz Single Channel PXIe Microwave Signal Generator that offers industry leading performance, in a modern modular 2 slot PXIe format that can be used on the desk, embeded in a system or or easily scaled up to multiple channels ATE systems.
-
product
64-Channel Form A General Purpose Switch for 34980A
34939A
The Keysight 34939A is a high density general-purpose switch module for the 34980A Multifunction Switch/Measure Unit. It has 64 independent single-pole, single-throw (SPST) relays that can switch 1A and carry 2A. This module can be used to cycle power to products under test, control indicator and status lights, and to actuate external power relays and solenoids. The relays are 100V, 1A contacts and can handle up to 60W. Standard 78-pin Dsub connectors allow for use with standard cables, screw terminal blocks, or mass interconnect solutions.
-
product
Signal, Patchcord, Receiver, 36", TriPaddle, 24 AWG White, Single Ended (3 Amp)
7-104924000-036
Signal, Patchcord, Receiver, 36", TriPaddle, 24 AWG White, Single Ended (3 Amp).
-
product
SSA Signal Source Analyzer, 10 MHz to 7 GHz, 26.5 GHz, or 110 GHz
E5052B
RF Input frequency range: 10 MHz to 110 GHz Analysis offset frequency range: 1 Hz to 100 MHz Phase noise measurement with ultra low noise floor and a cross-correlation method Frequency transient capture range: up to 80 MHz in narrow band, up to 4.8 GHz in wide band
-
product
Standard 1.00 (28.00) - 3.20 (91.00) General Purpose Probe
P2550-8
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,453Overall Length (mm): 36.91Rec. Mounting Hole Size (mil): 126Rec. Mounting Hole Size (mm): 3.20Recommended Drill Size: #30 or 3.20 mm
-
product
Ultra High 4.09 (116.00) - 10.00 (283.00) General Purpose Probe
EPA-2J30-2
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
2.5GS/s 16Bit 2GS Mem 2CH Arbitrary Waveform Generators
P2582B
The Proteus P2582B, is a 2.5GS/s, dual channel arbitrary waveform generator packaged in a 4U, 19” standalone box with a 9” touch screen and on board PC , offering technologically advanced options and configurations that integrate the ability to transmit, receive and perform digital signal processing all in a single instrument. The P2582B offers industry leading performance Including an innovative task oriented programming, real time data streaming, fast feedback loop for environment dependent waveform generation and user customizable FPGA for application specific solutions.
-
product
Signal, Contact, ITA, TriPaddle, 10 Amp, 14-18 AWG
610110129
Primary mating contact 610110128. (May mate with other Receiver contacts, as well.)Specifications Operating Voltage & Current 10 Amps Max. Continuous (14 AWG)600 Volt Max. use of wire Mil-W-16878/4Contact Resistance 4 mOhms Max.Measured at 50 mV @ 100 mAContact Body BrassContact Plating 30µ” Au over 100µ” NiContact Termination Crimp/SolderCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs.) 0.41
-
product
G-S General Purpose Probes
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 780Overall Length (mm): 19.81Rec. Mounting Hole Size (mil): 86Rec. Mounting Hole Size (mm): 2.18Recommended Drill Size: #44
-
product
Standard 0.39 (11.00) - 1.39 (39.00) Replaceable General Purpose Probe
MEP-30J
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 30Test Center (mm): 0.76Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 690Overall Length (mm): 17.53
-
product
Cup, Straight Shaft Concave, Alternate 0.78 (22.00) - 3.70 (105.00) General Purpose Probe
HPA-0G21-1
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
product
Signal, Contact, ITA, QuadraPaddle, 5 Amp, .025" Square Post for Wire Wrap with Anti-Rotation
610138122
Primary mating contact 610138200. (May mate with other Receiver contacts, as well.)Available in twin-female, crimp/solder, twin male, and wire-wrap design, QuadraPaddle contacts are engineered for flexible interconnect options. Rated at 5 amps continuous (1250 VAC) with a 2 ounce insertion force, QuadraPaddle contacts provide 4 reliable points of contact per pin, outstanding electrical performance, and low mating force.Specifications Operating Voltage & Current 5 Amps Max. Continuous; 600 volt Max. use of wire Mil-W-16878/4Contact Resistance 25 mOhms Max.Measured at 50 mV @ 100 mADielectric WithstandingVoltage (DWV) 1500 VDC Min.Insulation Resistance 5000 MOhms Min.Contact Body BrassContact Plating 30µ” Au over 100µ” NiCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs) 0.24
-
product
Ultra High 4.09 (116.00) - 10.00 (283.00) General Purpose Probe
EPA-2F-2
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
PCI-5412, 100 MS/s, 14-Bit Waveform Generator Device
779177-02
The PCI‑5412 can generate user-defined, arbitrary waveforms and standard functions, including sine, square, triangle, and ramp. This arbitrary waveform generator can generate signals from -6 V to +6 V and uses direct digital synthesis (DDS) to precisely generate waveforms.
-
product
Ultra High 12.90 (366.00) - 48.00 (1361.00) General Purpose Probe
EPA-5A-2
Current Rating (Amps): 8Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,420Overall Length (mm): 36.07
-
product
Signal, Contact, ITA, TriPaddle, Round Post, PCB Mount
610110000
Primary mating contact 610110179. (May mate with other ITA contacts, as well.)Specifications Operating Voltage & Current 5 Amps Max. Continuous (20 AWG)600 Volt Max. use of wire Mil-W-16878/4Contact Resistance 4 mOhms Max.Measured at 50 mV @ 100 mAAVG Mating Force(lbs) 0.41Dielectric WithstandingVoltage (DWV) 1500 VDC Min.Insulation Resistance 4000 MOhms Min.Contact Body BeCuContact Plating 30µ” Au over 100µ” NiCycle Life 20,000 Cycles
-
product
PXIe-6547, 100 MHz, 32-Channel PXI Express PXI Digital Waveform Instrument
781011-02
PXIe, 100 MHz, 32-Channel PXI Express PXI Digital Waveform Instrument—The PXIe‑6547 is a digital waveform generator and analyzer for interfacing and basic characterization test with 32 single-ended digital pins. The device is capable of sampling digital waveforms at up to 100 MHz and interfacing with user-programmable voltage levels that have a 100 mV resolution. The PXI‑6547 also features advanced synchronization capabilities for building integrated mixed-signal test systems, hardware comparison for bit-error test, and per-bank digital timing features.
-
product
Alternate 2.64 (75.00) - 6.50 (184.00) General Purpose Probe
EPA-2F-1
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-3
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
product
Signal, Contact, Receiver, QuadraPaddle, 5 Amp, 22-28 AWG, 50µ” Au, Crimp
610138116
*Please note: The difference between this p/n and 610138216 is the amount of gold plating. See below.P/n 610138116- 50µ" AuP/n 610138216- 30µ" AuPrimary mating contact 610138112. (May mate with other ITA contacts, as well.)Specifications Operating Voltage & Current 5 Amps Max. Continuous; 600 volt Max. use of wire Mil-W-16878/4Contact Resistance 25 mOhms Max.Measured at 50 mV @ 100 mADielectric WithstandingVoltage (DWV) 1500 VDC Min.Insulation Resistance 5000 MOhms Min.Contact Body BeCuContact Plating 50µ" Au over 100µ" NiCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force(lbs) 0.24
-
product
Standard 1.55 (44.00) - 3.20 (91.00) General Purpose Probe
HPA-50T
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 590Overall Length (mm): 14.99
-
product
HPA-0B General Purpose Probes
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13