Impedance Testers
See Also: Loop Impedance Test, Impedance Analyzers
-
Product
Vector Impedance Analyser
TE3000
-
The TE3000 Vector Impedance Analyser is a portable desktop instrument designed for high accuracy impedance measurement. The probe style construction and small output signal make it ideal for "in circuit" impedance characterisation of small signal devices without the risk of damage to the device under test. The TE3000 comes factory calibrated to the tip of the probe with optional custom calibration. Turn it on, set the frequency, take a measurement, and display the results in any format.
-
Product
Impedance Standards and Calibrators
-
Impedance Calibrator is to replace countless single value RCL standards with one calibrator that can switch between the standards like a CD changer in your car. The calibrator contains stable and temperature independent resistance standards, partial capacitance standards and partial inductance standards, simulated by RC T-type passive network. Calibration values of both complex parameters of partial standards are displayed on large LCD screen in preselected pairs of parameters as well as voltage, current and frequency readouts from built-in test signal meter. OPEN and SHORT reference positions are available as well.
-
Product
Impedance Analysis
S96041B
-
Make impedance analysis measurements of Surface Mount Device (SMD) components on the E5080B vector network analyzer with 16198A-010 10 GHz SMD test fixture.
-
Product
Impedance Matching Pads
-
These impedance matching pads are resistive networks that can be used to match 2 devices with different nominal impedances. The resistive network used in these impedance matching pads has a 5.7db theoritical insertion loss; true loss is 5.7db plus the normal other losses. common use is to connect 50 ohm sma's to 75 ohm f's. There are also 75 ohm versons of N's, BNC's, & SMA's.
-
Product
Impedance Matching Pads
-
Impedance matching pads from BroadWave eliminate impedance discontinuity (mismatches) without introducing reflection to the circuit. Custom units are available in a variety of impedance and connector types from DC to 4 GHz. BroadWave Technologies impedance matching pads preserve signal integrity by matching virtually any transmission line.
-
Product
Manual Tuners / Impedance Tuners
-
Maury manual tuners are based on precision slide screw technology that utilizes broadband slab line transmission structure and passive probes to create impedances for devices. The probes are designed to be very close to onequarter wavelength in the linear dimension at the mid-band of each range. Since each tuner has two probes, this results in improved matching characteristics for each unit. Another key feature of this series of tuners is the inclusion of a LCD position readout of the carriage position on those units operating below 18 GHz. Higher frequency tuners utilize a micrometer carriage drive. The positional repeatability and high matching range of these tuners make them ideally suited for use as a variable impedance source in applications like device characterization. Such measurements depend upon the ability of the tuner to establish impedances out near the edge of the Smith chart and to reproduce the electrical characteristics as a function of mechanical position. The tuners in this series are also easy to use due to the nearly independent electrical results of the mechanical motions. The depth of penetration of the probe into the transmission line determines the magnitude of the reflection, while the position of the probe along the line determines the phase. While there is some interaction, the effects are almost independent of each other. https://www.maurymw.com/images/mw-rf/mst982e35.jpg
-
Product
High Impedance Probes
-
Everbeing offers GGB’s high impedance active probe for failure analysis of your devices. The high impedance with low capacitive design allows measurements of internal nodes without loading the device. For more information, please visit http://www.ggb.com.Everbeing offers GGB’s high impedance active probe for failure analysis of your devices. The high impedance with low capacitive design allows measurements of internal nodes without loading the device. For more information, please visit http://www.ggb.com.
-
Product
Antenna Impedance Analyzer
TZ-900 AntennaSmith
-
Analysis Parameters: SWR, Complex Impedance, R+jX, reflection coefficient, Smith Chart. 0.2 - 55 MHz• SWR
-
Product
Impedance Analyzers
HTF-1100.
-
A laboratory furnace used specifically for the electrical characterization of materials and also for heat treatment between ambient temperature and 1100 °C.
-
Product
High Impedance Active Probes
12C
-
A high speed, high input impedance active probe for measuring the internal node voltage of integrated circuits. The input is 1 megohm shunted by 0.1 pf and the rise/fall times are 0.8 ns. This instrument has full dc capability and can be used with any oscilloscope. The Model 12C was specially designed so that when used in conjunction with a high input impedance oscilloscope, signal attenuation is 10:1 and with a 50 Ohm input, signal attenuation is 20:1.
-
Product
Step & Touch & Earth Impedance
-
The kit applyed with STS 5000, STS 4000 or eKAM, allows to perform the following types of test: soil resistivity, ground grid resistance, step and touch tests and overhead lines zero sequence and mutual coupling coefficients
-
Product
FC Impedance Meters
-
designed for testing of the fuel cell with the small current (5 A or less), and not only the current-voltage characteristic test, the KFM2005 can easily measure for the impedance of a fuel cell using the AC impedance method, and the Cole-Cole plot. Using the measurement data of the Cole-cole plot, it is possible to calculate the circuit constant of the approximate equivalent circuit of the fuel cell. The built-in DC load (60W) is capable to operate from 0 V, and it can perform the test for the fuel cell up to 20V and 5A.
-
Product
High Impedance Active Probes
28 AND 29
-
Designed to serve the needs of integrated circuit engineers working in the most advanced high speed, submicron, MOS technology. These high frequency instruments include the attractive features of the Models 18C and 19 including full dc capability, negligible dc current drain, and extremely low input capacitance. In addition the frequency range of the Models 28 and 29 has been extended to a full 1 GHz.
-
Product
Impedance Meter
ZM-100
-
Monacor International GmbH & Co.
Impedance meter for measuring the impedance (Z) of individual loudspeakers and loudspeaker lines.
-
Product
Error Detector Remote Head 32 and 17 Gb/s
N4952A
Bit Error Rate Tester (BERT)
The N4952A is an affordable and compact error detector remote head available in 4 to 17 Gb/s and 5 to 32 Gb/s configurations. Compatible with the N4960A Serial BERT controller, it is the perfect solution to test up to 32 Gb/s per channel for 100 Gigabit Ethernet applications and other high-data rate devices. The N4952A error detector supports PRBS or user patterns and operates up to 32 Gb/s in a single band with no gaps or missing data rates. The remote head allows the test equipment to be located very close to the device under test, eliminating the need for long cables that degrade signal quality.
-
Product
Precision Impedance Meter
1689
-
The GenRad 1689 Precision Impedance Meter gives you the best performance for your most demanding applications whether they be production test, incoming inspection, component design and evaluation, process monitoring or dielectric measurement. It is a versatile, full function microprocessor-based passive component tester that's available in a rack mountable, (1689M) model.
-
Product
High Impedance Transformers
-
Osborne high impedance transformers are used to step-up, step-down and isolate voltages in single phase and three phase circuits. A properly designed high impedance transformer can be used an an equivalent to an isolation transformer connected in series with an inductor. The high impedance characteristic may be employed as a current limiting feature in both the primary and secondary circuity.
-
Product
High Impedance Differential Clock Divider
-
Alliance Support Partners, Inc.
he ASP-DCD-00 board is a high impedance input clock divider circuit. It is designed to provide minimum load to a clock source for frequency measurement. It accept single ended (Unbalanced) or differential (Balanced) signals with amplitudes as little as 100mV rms; it divides the input signal frequency from 2 to 256 times depending on shunt jumper selections on J3. The board requires 5VDC 500mA power source to operate. The output is capable of driving 5V TTL logic levels.
-
Product
Return Loss, Impedance & Balance Measurement Accessory
Model SLM620-1
-
For Loss- Frequency Range : 300Hz to 620KHz.- Impedance : 60 to 1000 ohms (40dB maximum).- Accuracy : ±1dB (upto 300KHz) ±2dB (300KHz to 620KHz).For Impedance- Frequency Range : 300Hz to 620KHz.- Impedance : 60 to 3000 ohms.- Accuracy : ±10% (upto 300KHz) ±20% (300KHz to 620KHz).
-
Product
Impedance Analyzer 1MHz-20Hz
IA1000
-
Frequency range20 ~ 1MHzFrequency accuracy0.005%Frequency resolution0.001% in all frequency rangeTest signal level0.05 ~ 2.0 VrmsTest signal resolution0.001 VrmsTest signal output impedance100ΩImpedance Z range; basic accuracy0.0000Ω ~ 99.99
-
Product
Impedance Analysis For E5061B-3L5 LF-RF Network Analyzer
E5007A
Network Analyzer
The E5007A provides the impedance analysis (ZA) firmware for the E5061B LF-RF network analyzer. This option enables the analyzer to measure impedance parameters of electronic components such as capacitors, inductors, and resonators. The combination of NA and ZA capabilities further enhances the analyzer’s versatility as a general R&D tool. Basic ZA functionalities including fixture compensation and equivalent circuit analysis are supported by the firmware. The DC biased impedance measurement is possible with the built-in DC bias source provided by the E5061B-3L3/3L4/3L51.
-
Product
RF Impedance Transformers
-
Are designed and optimized to best deliver power into an impedance of 50 Ohms.
-
Product
High Impedance Active Probes
34A
-
Engineered to meet the stringent demands of advanced high frequency circuit designers. This high impedance probe combines full DC capability, rise/fall times of 120 ps, and a nominal loading input impedance of 10 megohm shunted by 0.1 pf. Signal attenuation is 20:1 with a 50 ohm oscilloscope input.
-
Product
Impedance Analyzers
-
The E4990A Impedance Analyzer with a frequency range of 20 Hz to 120 MHz provides an industry best 0.045% (typ.) basic accuracy over a wide impedance range, with a 40 V built-in DC bias source.
-
Product
Impedance Spectroscopy
NuVant EZware-EIS Software Package
-
The NuVant EZware-EIS software package activates Electrochemical Impedance Spectroscopy on the EZstat-Pro, Powerstat-05 and -20 potentiostat/galvanostats. EZware-EIS exports the impedance data to a file format to accommodate free third party EIS analysis software. EZware-EIS is a user-friendly interface that allows selection of the proper scanning parameters, collect the impedance spectra, display data in Nyquist and/or Bode plots and export data in the proper data format for use in EIS analysis software.
-
Product
Surge Tester (Impulse Winding Tester)
SS6815 / SS6815F
-
Surge testers (impulse winding tester) is used for testing and check the insulation grade of turns between turns, insulation grade of layers between layers, insulation grade of windings between turns. It is used widely for transformer, current sensor, voltage sensor, relay, contactor, inductor, motor, generator, valve coil, voice coil, etc.
-
Product
Electroscope Tester
-
Weshine Electric Manufacturing Co., Ltd
1. The high voltage is extremely spherical and the grounding voltage is annular.2. The grounding electrode is fixed and the high voltage electrode can be electrically driven to move to the left and right.3. The motor is controlled by two ways: button and wireless remote control. At the same time, there is fine tuning control, which is easy to adjust the distance accurately.
-
Product
Modular Testers
-
Modulare adaptronic wiring testers of the NT 700 series designed according to your test requirements. The design in mobile cabinets allows the integration of manifold test functions.





























