Current Transformers
transfers accurately proportional levels of current to multiple circuits.
-
Product
Loading Transformer
CL-6
-
This readily portable Knopp Loading Transformer weighs only 60 pounds and measures 12″ long, 9″ wide, and 10″ high. Its sturdy enclosure provides protection and adequate ventilation. Two convenient carrying handles are provided. The insulating terminal panel is rigidly secured to the transformer frame, and heavy-current, bus-bar-type terminals are securely bolted to the panel. The two outpout terminals each have two connection surfaces, one on a vertical plane and one on a horizontal plane, for maximum convenience in connecting the heavy current leads and in changing, when necessary, the series-parallel links. The links and the output connections cannot interfere with each other. All terminals and connection links are plated
-
Product
Isolated Hall Effect Current Sensors
-
Isolated Hall Effect current sensors provide accurate high bandwidth current sensing. Vektrex offers models to 320A. For use, the 50-ohm voltage output is connected directly to an oscilloscope or data acquisition system. VCS sensors are magnetically isolated like clamp-on oscilloscope probes. With secure cable attachment, repeatability is ensured.
-
Product
Sound Harmonics and Current Analyzer
H74050100
-
This analyzer is used as end of line control for electro mechanic components with electric motors, with or without mechanical reduction. While the motor is running at nominal speed, a spectrum and temporal analysis of the sound as well as a current consumption test is performed. Statistical analysis of the data acquired is also performed real-time, expediting the PASS/FAIL decision of the DUT.
-
Product
Wireless Connectivity AC / DC Clamp Meter with 6000 count / NCV / SPT / 600A AC / DC Current
MS-W366D
-
This is a external wireless connectivity Digital Clamp Meter integrated with AC / DC hall effect sensor / 6000 Count, True RMS, auto and manual measurement.
-
Product
30 A, 10 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 3 Meter Cable
CP030-3M
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
Pulsed Eddy Current (PEC)
Lyft®
-
Lyft is a high-performance solution reinventing pulsed eddy current (PEC). The patent-pending Eddyfi® solution features:
-
Product
Hipot Current Calibration Load Resistors
HPRS-HIPOT-LOAD
-
The IET HPRS-Hipot-Load is an excellent replacement for the Fluke 5320A-Load Hipot current calibration load resistors. The IET high power resistive load can be used with the Fluke 5320A Multifunction Electrical Tester Calibrator or standalone. It provides a high power and high voltage load to various hipot tester to create the leakage current needed to calibrate various manufactures hipot testers.
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-500B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
Clamp type AC Current Sensor/with DC Voltage Output
RCT-18
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
Leakage current measurements with DCV output for recorder. AC 0.1mA~100mA.
-
Product
High Current / High Temperature Spring Probes
-
We have spring probes, which can be used for high temperature and high current test under 200 degree and shows high performance in them.
-
Product
Measuring Device for Testing the Effectiveness of Residual Current Protective Devices (RCD) According to DIN EN 61557-6 (VDE 0413-6)
-
PeakTech Prüf- und Messtechnik GmbH
A residual current tester, which is used to determine tripping currents and the tripping times of residual current circuit breakers, which are used in every new building according to current building regulations. Residual current circuit breakers are used for personal protection and switch off a circuit when a residual current is registered which flows off via the protective earth (PE).
-
Product
Calibrator, Calibrated, Current, 185 mm, 78 mm, 38 mm, ± (0.25% FS +1 digit), ± (0.5%FS + 1 digit)
72-6694 CAL
-
The 72-6694 CAL from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
Product
PXI/PXIe Wide Current Range Multiplexer Module, Single 6-Channel, 4-Pole
40-514-102
-
The 40-514-102 (PXI) and 42-514-102 (PXIe) are low density multiplexers in single 6-channel, 4-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
Product
Bulk Current Monitoring Probe
MP-50
-
The Current Monitoring probes may be used whenever RF current measurements are required. Current measurements are made by placing a current carrying conductor within the “sensing” window of the probe and measuring the probe’s output voltage with an RF detector. Calibration of the probe permits the conversion of the voltages measured to current. Current measurements can be made over the frequency range shown in the transfer impedance curve furnished with each probe. There is virtually no loading of the circuit and the technique permits normal operation of the device under test during measurements. The MP-50 can be used for the procedure for clamp injection when the common- mode impedance requirements cannot be met given in chapter 7.4 of IEC/EN 61000-4-6 „Immunity to conducted disturbances, induced by radio frequency fields”. The MP-50 can also be used as current monitor for BCI testing as per ISO11452-4, RTCA/DO-160 section 20, MIL-STD-461 and various automotive standards.
-
Product
150A, 12 MHz CURRENT PROBE, BNC, AC/DC, 150A rms, 300A Peak Pulse
T3CP150-12
-
150A, 12 MHz CURRENT PROBE, BNC, AC/DC, 150A rms, 300A Peak Pulse.
-
Product
NI-9203, 200 kS/s, ±20 mA, 8-Channel C Series Current Input Module
779516-02
-
200 kS/s, ±20 mA, 8-Channel C Series Current Input Module - The NI‑9203 is intended for high-performance control and monitoring applications. It features programmable input ranges and variable connectivity options. To protect against signal transients, the NI‑9203 includes a channel‑to‑earth ground double‑isolation barrier (250 Vrms isolation) for safety and noise immunity.
-
Product
4 Phase MICRO~Flex AC Current Probe
DRM 504/4
-
The new DRM 504/4 is a 4 Phase MICRO~flex AC current Probe utilising the Rogowski principle, with 4 channel integrator housed in DIN Rail Mounted Enclosure. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and with large conductors.
-
Product
Automated Leakage Current Tester
LINECHEK® II Series
-
Our LINECHEK II Leakage Current Tester is designed for medical device manufacturers. With a feature set built around maximizing the efficiency of the Leakage Current test, LINECHEK II satisfies medical application requirements demanding up to 40 Amps of continuous line current. Use it on the bench or in a rack, from the front panel or via a PC interface to ensure your medical device is ready for global deployment.
-
Product
30A, 100MHz High Sensitivity Current Probe
CP031A
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
Clamp type AC Current Sensor/for Load Current Measurements(CT Series)
CT-40
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Compact size*AC 1A~600A*Current measurements of feeder
-
Product
AC/DC High Sensitivity Clamp-On Current Probe
N7026A
-
The Keysight N7026A is a 150 MHz bandwidth, active current probe for InfiniiVision and Infiniium oscilloscopes. The probe features wide and flat bandwidth (DC-150 MHz), lower noise (<250 µArms), and wide input range (up to continuous 30 Arms or non-continuous 40 Apeak). This enables you to measure down to 1 mA/div, giving you a much more accurate view of your low-level signals.
-
Product
Instrument Transformer & Switchgear Testing
-
Our stationary and mobile instrument transformer test systems are used to test current and voltage instrument transformers. Among other things, accuracy testing, demagnetization and insulation testing are possible.
-
Product
Wall Transformer, Converters & Chargers
-
PeakTech Prüf- und Messtechnik GmbH
An appliance for holding or inserting a charge of power.
-
Product
Current Clamps and Sensors
-
Are designed for measuring leakage current diverted towards the earth. It enables the fault to be located or anticipated without disconnecting the equipment linked. It is specially designed to detect low fault currentson power circuits.
-
Product
Uniload Voltage Transformer
2J4-4
-
The Type 2J4-4 Knopp Uniload Voltage Transformer Test Set consists of three major parts:
-
Product
Peripheral Level Transformer
-
The Peripheral Level Transformer (PLT) is an adapter module that increases the voltage of the analog inputs&outputs for easy communication with external devices. It is connected between the instrument and the periphery.
-
Product
Through Hole type AC Current Sensor
CT-6K
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
For measuring current generally (through hole type)
-
Product
Split Type AC Current Sensor
CTF-16
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*For AC current and power measurements.*Wide measuring range (AC 0.1~100A).*Compliant with RoHS drective.
-
Product
SparkFun Current Sensor Breakout
ACS723 (Low Current)
-
The low current version of the SparkFun Current Sensor Breakout is a high accuracy board that utilizes the ACS723 for low to moderate AC and DC current sensing applications. The ACS723 sensor uses a Hall effect sensor to output a voltage relative to the current flowing through the IP+ and IP- pins on the board. The advantage of using a Hall effect sensor, specifically, is that the circuit being sensed and the circuit reading the sensor are electrically isolated meaning that, although your Arduino is running on 5V, the sensed circuit can be operating at higher DC or AC voltages!
-
Product
150 Amps, 10 MHz BW Current Probe - AC/DC , 500 Amp Peak Pulse
CP150
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.