Visual Fault Locators
Apply light to optical fibers, enabling visual inspection to determine integrity.
See Also: VFL
-
Product
Compact OTDR
-
◇ 5.6-Inch outdoor-enhanced touchscreen, 7.4V/4.4Ah Lithium battery◇ Event Dead zone as lower as 1.5meter◇ Combined multi-dynamic range and wavelengths◇ Muti measurement mode, support Touching LCD and pressing keys◇ Warning function could prevent OTDR module from being damaged by optical signal in fiber.◇ Realtime measuring function, convenient to monitor the splicing process◇ Integrated 10mw Visual Fault Locator◇ Support English/ Chinese input, adopts friendly input interface, totally simulate the computer keyboard input ◇ Integrated with 8GB internal memory, more than 80,000 groups curve storage◇ PC remote access and control function is available, which support the printing work of the measurement report
-
Product
Visual Fault Locator
VFL X5003
-
Constant & stable output powerLow battery warning, reminds users to change the battery timely.Long battery life (up to 40 hours with AAA batteries)Pocket size and light weight, easy to use.Re-changeable ceramic tube, to avoid returning to manufacturer for this small fault.
-
Product
Pen-type Visual Fault Locator
PVLS Series
-
Shanghai Tarluz Telecom Tech Co., LTD
PVLS Series Pen-type Visual Laser Source (VFL) is specially designed for field operators who need an efficient and economical tool for fiber tracing, fiber routing and continuity checking in optical network. It includes threen main functions, Finding the breakpoint, poor connections, bending or cracking in fiber optic cables, Identifying the faults of OTDR dead zone, End-to-end visual fiber identification.
-
Product
Smart Optical Time Domain Reflectometer OTDR
BD900 Series
-
Shanghai Baudcom Communication Device Co.,Ltd.
BD900 series of Optical Time Domain Reflectometer has excellent dead zone performance and wide dynamic range. There are four models to choose from and that can betterly meet the customer’s specific measurement requirements. Combined with the visual fault locator, it can easily find the breaks, bends, splices, faulty connectors, and other causes of signal loss.
-
Product
Visual Fault Locator VFL
X4007
-
X-4007 series visual fault locator is used for the measurement in single-mode or multi-mode fibers. It features a rugged design, a universal connector and an accurate measurement.
-
Product
2.5mm Visual Fault Locator
3105
-
Anfkom International Co.,Limited
The 3105 Pen type VFL is specially designed for field personnel who need an efficient and economical tool for fiber tracing, fiber routing and continuity checking in optical network. It includes:Finding the breakpoint, poor connections, bending or cracking in fiber optic cables.Finding the faults of OTDR dead zoneEnd-to-end visual fiber identification
-
Product
Visual Fault Locator
FFL-310-U
-
FFL-310-U Visual Fault Locator is equipped with a 650 nm high power visible laser diode,can be operated in -CW (continuous) or … MOD (1Hz modulation) mode. There is one LED indicator:with RED or GREEN light; the RED one shows the operating mode of the laser diode output signal, and the GREEN one indicates low battery level. FFL-310-U is designed in a card-size dimensions.
-
Product
OTDR
EXFO-100
-
Hangzhou Softel Optic Co., Ltd.
* Top user-friendliness: one-button testing, combined with EXFO’s proprietary FTTx software package (macrobend/fault finder, pass/fail indicators)*Multiple options, including power meter, visual fault locator (VFL), fiber inspection probe, printer and IP testing*Fault Finder mode, for quick identification/location of a fiber break*Complete connectivity flexibility: USB stick compatibility and USB cable data download via ActiveSync**Advanced TFT transflective color display, for assured legibility under direct sunlight or in other demanding outside conditions*Handheld, small, lightweight unit: 1 kg (2.2 lb)*Built-in ruggedness for outside-plant usage*Troubleshooting option, enabling in-service, out-of-band network testing *EXFO’s AXS-100 Access OTDR combines the industry’s leading OTDR technology with power meter functiona lities in one powerful handheld unit.Optimized for testing passive optical networks (PON) within FTTx architectures, it offers several wavelength configurations and a wide range of options, for first-class flexibility. Use it at the optical network terminal(ONT), drop terminal or fiber distribution hub (FDH) for FTTH distribution(F2) fiber characterization, troubleshooting and fault locating.
-
Product
Optical Power Meter & VFL
X0563
-
Optical power meter X-0563 combines the handheld optical power meter and the visual fault locator(VFL) functions in one unit. It can be used for the absolute power measurement and relative measurement of the link loss in dB. Its compact size, friendly operation interface, broad power measurement range, high precision and brand-new user automatic calibration function and high performance in application makes it an ideal tool for optical fiber network.
-
Product
Visual Fault Locator
HW-205
-
Shanghai Fibretool Technology Co.,Ltd.
The HW-205 is specially designed for field personnel who need an efficient and economical tool for fiber tracing, fiber routing and continuity checking in an optical network during and after installation.- 2.5mm universal connector- Operates either in CW or Pulsed- Constant output power- Long battery life (up to 60 hours)- Laser case ground design prevents ESD damage- Portable and rugged, easy to use- Burning testing to ensure the reliability.- Optional 1.25mm connector adapter
-
Product
Tool, Locator, QuadraPaddle, ITA
910104140
Locator Tool
Used with Crimp Tool p/n # 910101103 to crimp QuadraPaddle contacts to 22-28 AWG wire.
-
Product
Tool, Locator, Thermocouple, Receiver
910104134
Locator Tool
Used with Crimp Tool Part # 910101102 to crimp thermocouple receiver contacts.
-
Product
PXI/PXIe Fault Insertion Switch, 32-Chan 2A, N/C Through Relays, Fault Buses on M & U
40-190C-212
Fault Insertion Unit
The 40-190C-212 (PXI) and 42-190C-212 (PXIe) are fault insertion switches with 32 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI Single Bus 32-Ch 2A Fault Insertion Switch, N/O Through Relays
40-190B-501
Fault Insertion Unit
The Single Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI 5A Fault Insertion Switch 5-Channel
40-196-101
Fault Insertion Unit
The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.
-
Product
PXI Single Bus 74-Ch 2A Fault Insertion Switch
40-190B-001
Fault Insertion Unit
The Single Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 8 Channel
50-201-008
Fault Insertion Unit
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
Product
PXIe 10GBase-T1 Ethernet MEMS Fault Insertion Switch, 8 Channel
42-205-008
Fault Insertion Unit
The 42-205-008 (PXIe) is an 8-channel fault insertion switch designed to simulate common faults on high speed two wire communication interfaces such as xBaseT1 Ethernet. It is available with 4 or 8 channels of two wire serial connections and can be used for simulating faults on 10BaseT1, 100BaseT1, 1000BaseT1 and 10GBaseT1 Ethernet interfaces. Any wire can be set as open circuit and shorts can be applied across wire pairs. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to supply voltage or ground.
-
Product
PXI/PXIe Fault Insertion Switch, 74-Chan 2A, N/C Through Relays, Fault Buses on M & U
40-190C-012
Fault Insertion Unit
The 40-190C-012 (PXI) and 42-190C-012 (PXIe) are fault insertion switches with 74 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI Single Bus 64-Ch 2A Fault Insertion Switch
40-190B-101
Fault Insertion Unit
The Single Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI/PXIe Fault Insertion Switch, 32-Chan 2A, N/C Through Relays, Fault Buses on M & U
42-190C-212
Fault Insertion Unit
The 40-190C-212 (PXI) and 42-190C-212 (PXIe) are fault insertion switches with 32 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
Dual Bus 36-Channel 2A PCI Fault Insertion Switch
50-190-202
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
Battery Fault Insertion Unit
Fault Insertion Unit
The Battery Fault Insertion Unit (FIU) provides intelligent switching of cell-simulation channels for the Battery Simulator 1200. The switching capability enables simulation of open-circuit and short-to-rail fault conditions on any cell channel for the purposes of battery management system (BMS) testing. Additionally, a four-wire auxiliary input allows you to connect an external digital multimeter (DMM) instrument to any cell channel for very high-accuracy bypass current and cell voltage measurements. Each FIU provides 24 independently-programmable cell-switching channels for one or two 12-cell Battery Simulator 1200 units. Additional Battery Simulator 1200 and FIU instruments can extend functionality up to 120 series-connected cell channels.
-
Product
PXI 16-Channel 4-Bus 2A Fault Insertion Switch
40-197A-002
Fault Insertion Unit
This 16-channel fault insertion switch is primarily intended for routing simulated fault conditions in automotive and aerospace applications involving the reliability testing of safety critical controllers.
-
Product
PXI-2510, 68-Channel, 2 A PXI Signal Insertion Switch Module
778572-10
Fault Insertion Unit
68-Channel, 2 A PXI Signal Insertion Switch Module—The PXI‑2510 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2510 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
Product
Tool, Locator, TriPaddle, Receiver
910104127
Locator Tool
Used with crimp tool part # 910 101 103 to crimp TriPaddle receiver contacts to 20-28 AWG wire. This locator contains an integrated wire stop for consistent contact crimping.
-
Product
PXI Single Bus 32-Ch 2A Fault Insertion Switch
40-190B-201
Fault Insertion Unit
The Single Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI 10A Fault Insertion Switch 10-Chan 2-Bus
40-199-002
Fault Insertion Unit
The 40-199 is a 10 Channel Fault Insertion switch designed for the simulation of fault conditions in automotive/avionics applications, involving the reliability testing of safety critical controllers.
-
Product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A
40-194A-001
Fault Insertion Unit
The 40-194A-001 is a 7-Channel PXI Fault Insertion switch with one fault bus, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
Product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 8 Channel
50-200-008
Fault Insertion Unit
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.