Fiber Optic Multiplexers
Process multiple optical signals into one single optical signal.
-
Product
PXI Very High Density Versatile 2-Pole, 2 Amp Multiplexer
40-613A-002
Multiplexer Module
The 40-613A Very High Density Versatile 2-pole Multiplexer module features a wide range of software selectable switching configurations. It is especially useful where a number of high density multiplexers are required with the option of easily altering the channel count as a test system evolves.
-
Product
PXI High Density MUX BRIC, 8-Chan, 40-Pole
40-570-212
Multiplexer Module
This range of High-Density Multiplexer is part of our BRIC family. These MUX's are designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is also possible, without limitation). These multiplexers are ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. They are available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts. All version are supported in a BRIC8 construction that occupies eight PXI 3U mechanical slots, one of which provides the PXI interface and power.
-
Product
PXI 5A Mux 8-Bank 5-Ch Isolated COM
40-651-014
Multiplexer Module
This range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats: 1-bank 48-channel. 2-bank 24-channel. 4-bank 11-channel. 8-bank 5-channel.Connections are made via a front panel 50-way male D-type connector. Power multiplexer modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP4T, 67 GHz, 50 Ω, SMA-1.85, Remote Mount, Failsafe
42-785C-471-E
Multiplexer Module
The 40-785C-471-E (PXI) and 42-785C-471-E (PXIe) are single failsafe SP4T 67 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI Switched Guard Reed Relay Module, 16x 2:1 Multiplexer
40-121-011
Multiplexer Module
The 40-121-011 provides 16x 2:1 multiplexers in a single slot PXI module and designed to provide an isolation resistance in excess of 1013Ω. It has been designed to ensure high isolation resistance through the use of switched guards, making it ideal for low level measurements and semiconductor test.
-
Product
LXI High Voltage Multiplexer Plugin Module
65-231-904-HI
Multiplexer Module
The 65-231-904-HI plug-in module is part of a scalable high voltage multiplexer platform that provides a high voltage switching solution with capability up to 9 kV.
-
Product
PXI 2A Multiplexer, 8-Bank, 8-Channel, 2-Pole
40-614C-004
Multiplexer Module
This 8-bank, 8-channel, 2 pole version is part of the 40-614C High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI High Density Mux 10 Channel 8 Pole
40-670A-021-10/8
Multiplexer Module
The 40-670A series of very high density multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
Product
PXI High Density MUX BRIC, 4-Chan, 80-Pole
40-570-112
Multiplexer Module
This range of High-Density Multiplexer is part of our BRIC family. These MUX's are designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is also possible, without limitation). These multiplexers are ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. They are available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts. All version are supported in a BRIC8 construction that occupies eight PXI 3U mechanical slots, one of which provides the PXI interface and power.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 26.5GHz, 50Ω, SMA, Remote Mount
40-785C-532-E
Multiplexer Module
The 40-785C-532-E (PXI) and 42-785C-532-E (PXIe) are dual SP6T 26.5GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
PXI/PXIe High Density 2A Multiplexer, 5-Bank, 8-Channel, 3-Pole
42-614D-021
Multiplexer Module
The 40-614D-021 (PXI) and 42-614D-021 (PXIe) 5-bank, 8-channel, 3-pole multiplexers are part of the High Density 2A multiplexer module range available in 23 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
LXI Microwave Multiplexer, 50Ω 4-Channel 6-Bank 18GHz SMA
60-802-206
Multiplexer Module
The 60-802-206 is a 4-channel, 6-bank RF multiplexer suitable for switching 50Ω signals up to 18GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP10T, 18 GHz, 50 Ω, SMA, Terminated, Failsafe
42-788-121-T
Multiplexer Module
The 40-788-121-T (PXI) and 42-788-121-T (PXIe) are single failsafe SP10T 18 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP8T, 40 GHz, 50 Ω, SMA 2.9, Terminated
40-788-051-T
Multiplexer Module
The 40-788-051-T (PXI) and 42-788-051-T (PXIe) are single SP8T 40 GHz microwave multiplexers with automatic termination of unused signals.
-
Product
PXI Solid State Multiplexer Module, Dual 3-Channel, 30 A, Hardware Interlock
40-667C-011-HI
Multiplexer Module
The 40-667C-011-HI is a dual 3-channel 30A MUX with hardware interlock and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation.
-
Product
PXI/PXIe High Density 2A Multiplexer, 10-Bank, 4-Channel, 3-Pole
42-614D-022
Multiplexer Module
The 40-614D-022 (PXI) and 42-614D-022 (PXIe) 10-bank, 4-channel, 3-pole multiplexers are part of the High Density 2A multiplexer module range available in 23 configurations (see 'Also in this Range' link above).
-
Product
PXI 3A Power MUX BRIC, 4-Channel, 48-Pole
40-571-004
Multiplexer Module
The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.
-
Product
PXI Solid State Multiplexer, 10 Amp, Dual 3-Channel
40-666A-011
Multiplexer Module
The 40-666A-011 is a dual 3-channel 10A MUX and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.
-
Product
PXI/PXIe RF Multiplexer, Single 4-Channel, Terminated Common, 3GHz, 50Ω, SMB
42-876A-001
Multiplexer Module
The 40-876A-001 (PXI) and 42-876A-001 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 1 bank in a single slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module exhibits low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
Product
PXI/PXIe MEMS Optical MUX, 8-Channel, Multi-Mode, 62.5/125 Fiber, FC/PC Connectors, With Interlock
42-852A-118-M62.5-HI
Multiplexer Module
The 40/42-852A-118-M62.5-HI is a PXI/PXIe 8-channel multiplexer with FC/PC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
PXIe Microwave Multiplexer, Single SP6T, 26.5 GHz, 50 Ω, SMA, Terminated, Failsafe
42-785C-531-T
Microwave Multiplexer
The 40-785C-531-T (PXI) and 42-785C-531-T (PXIe) are single failsafe SP6T 26.5 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
LXI Microwave Multiplexer, 50Ω 6-Channel 15-Bank 40GHz SMA-2.9
60-801-415
Microwave Multiplexer
The 60-801-415 is a 6-channel, 15-bank RF multiplexer suitable for switching 50Ω signals up to 40GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
LXI Microwave Multiplexer, SP6T, 1-Bank, 67GHz, 50Ω, SMA-1.85
60-800-801
Multiplexer Module
Our 60-800-801 is a 1 bank SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 67GHz. The 60-800 range is capable of supporting up to 16 banks of 6 channel multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
Multiplexer 2:1 With De-Emphasis 32 Gb/s
M8062A
Multiplexer Module
R&D and test engineers who need to characterize serial interfaces of up to 32.0 Gb/s can use the M8061A 2:1 Multiplexer with optional de-emphasis to extend the rate of J-BERT M8020A and J-BERT N4903B pattern generator. For the most accurate receiver characterization results, the M8061A provides four calibrated de-emphasis taps, which can be extended to eight taps, built-in superposition of level interference and Clock/2 jitter injection. The M8061A is a 2-slot AXIe module that can be controlled via USB from the user interface of J-BERT M8020A as well as N4903B.
-
Product
PXI/PXIe MEMS Optical MUX, 8-Channel, Multi-Mode, 50/125 Fiber
40-852A-518-M50
Multiplexer Module
The 40/42-852A-518-M50 is a PXI/PXIe 8-channel multiplexer with ST connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
Product
PXI/PXIe MEMS Optical MUX, 8-Channel, Multi-Mode, 50/125 Fiber
40-852A-318-M50
Multiplexer Module
The 40/42-852A-318-M50 is a PXI/PXIe 8-channel multiplexer with MU (mini SC) connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
PXI 8-slot BRIC Multiplexer, 32-Channel, 20-Pole (6 Sub-cards)
40-570A-314
Multiplexer Module
The 40-570A-314 is a 32-channel, 20-pole High-Density Multiplexer and is part of our BRIC family. The 40-570A range is designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing.
-
Product
PXI/PXIe High Voltage Multiplexer, Hex 7-Channel, 2-Pole
40-321-123-HI
Multiplexer Module
The 40-321-123-HI (PXI) and 42-321-123-HI (PXIe) are hex 7-channel 2-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
Product
PXI Very High Density Versatile 2-Pole MUX
40-613-002
Multiplexer Module
The 40-613 Very High Density Versatile 2-pole Multiplexer module features a wide range of software selectable switching configurations. It is especially useful where a number of high density multiplexers are required with the option of easily altering the channel count as a test system evolves.
-
Product
PXI Microwave Multiplexer, Single SP6T, 26.5GHz, 50Ω, SMA
40-784B-031
Microwave Multiplexer
The 40-784B-031 (PXI) and 42-784B-031 (PXIe) are single SP6T 26.5GHz unterminated microwave multiplexers. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.




























