Partial Discharge
voltage discharge within an insulator causing dielectric breakdown.
See Also: Partial Discharge Detection, Partial Discharge Monitors, PD, PD Test, Partial Discharge Test
-
Product
Tan Delta Measurement
TD Series
-
While partial discharge measurement is suitable for detecting electrical trees, tangent delta measurement – also referred to as dissipation factor measurement – detects water trees which have formed in the insulation of the device under test.
-
Product
TEV Antenna
-
TEV sensor is a partial discharge sensor whose working principle is based on a direct Capacitive coupling with a Switchgears earthed metal case. The two ends of TEV sensor can be coupled magnetically to virtually any opening on a metal Surface. It picks up the electric signal given by PD activity onto the two metallic surfaces. Thanks to its special design has high sensitivity, larger than other single ended TEV sensors. His compact and robust design (passive sensor) makes the TEV the optimal sensor for direct installation on medium voltage Switchgears.
-
Product
Universal PD & EMI analyzer
Spark P3
-
Doble Spark P3 is a universal partial discharge (PD) and electromagnetic interference (EMI) analyzer that uses a software defined radio signal detector to identify characteristics of insulation system deterioration that could lead to the failure of high voltage equipment. It detects signals from suitable sensors in a frequency range between 9 kHz to 2 GHz for PD and EMI, and DC to 500k Hz for acoustic and reference voltage measurements.
-
Product
Automation
-
The Transformers and measurement capacitors used in high voltage and Partial Discharge test equipment are typically reliable over several decades of continious use. The control technology is however typically obsolete after only 10-15years. MPS offers automated , state-of-the-art High Voltage Testing Equipment with the following features.
-
Product
HV Coupling Capacitors
-
Our high-voltage coupling capacitors are a main component of our partial discharge test stations. They serve to decouple the partial discharge impulses and act as a voltage divider, the output voltage of which is matched to our partial discharge measuring devices (with integrated voltage measurement) and peak voltage measuring devices. These high-voltage components are also available separately in their various designs, sizes, capacities and voltage ranges.
-
Product
Cable Diagnostic Tools
-
For non-destructive diagnostic testing to determine the quality of a cable’s insulation with minimal risk of failure, HVI recommends tan delta and partial discharge testing for valuable diagnostic data about cable insulation integrity. Both use a VLF source to perform elevated voltage, off-line testing. Tan delta testing measures insulation health, while PD identifies specific problem areas and assesses their severity.
-
Product
Partial Discharge Calibrator
TPK-H
-
The high voltage-resistant Partial Discharge calibrator is used to determine the correction factor in the PD test circui.
-
Product
PARTIAL DISCHARGE test set
pdnt02
-
International Biological Laboratories
This Test Kit is used for non-destructive means of assessing the quality of high voltage transformers, motors, cables etc., which are used in generation & distribution of electric power.
-
Product
Battery Cell Insulation Tester
Chroma 11210
-
Chroma Systems Solutions, Inc.
Chroma 11210 battery cell insulation tester is an instrument used for accurately measuring leakage current (LC) and insulation resistance(IR) of battery jelly-roll/dry-cell as well as other insulation materials. In addition to standard LC/IR measurement, the 11210 has a unique function that detects partial discharge (PD) or flashover that may have occurred inside the insulation material during the high voltage insulation testing process.
-
Product
Dielectric Loss Tangent Testing Instruments
-
Insulation materials in electrical equipment are used between a pair of electrodes; therefore it can be expressed as capacitors. Applying AC voltage to a capacitor with insulation materials causes an energy loss due to the leak current, the dielectric polarization, and the partial discharge. Because of this, the phase of the capacitor current is more delayed than that of a zero-loss current (reactive current) flowing in an ideal insulation material. The delay angle is called "Dielectric Loss Angle", and the tangent is "Dielectric Loss Tangent" (tanδ). Please refer to the technical guide explained in detail.
-
Product
PD Measuring System
TEM
-
Partial discharge test system for laboratory or on-site measurement according to VDE 0434, IEC 60270 and EN50178 consisting of:*Partial discharge meter TMG*High-voltage coupling capacitors for decoupling of the PD pulses*Partial discharge calibrator TPK for determining the correction factor in the PD test circuit
-
Product
Partial Discharge Test
INDIPORT
-
For medium voltage switchgear - partial discharge test in a few minutes - without shutdown.
-
Product
High Frequency Current Transformer Clamps
HFCT-20HD & HFCT-60HD™
-
The HFCT-20HD™ and HFCT-60HD™ are high frequency current transformer sensors designed for partial discharge detection on electric apparatus’ ground returns. Made from superior quality materials, it is designed for any environment.
-
Product
Shielded Rooms
-
HIGHVOLT Prüftechnik Dresden GmbH
Electromagetic field and line-conducted interference needs to be eliminated in order to measure low-intensity partial discharges with a PD background noise level (≤ 1 pC) in accordance with IEC 60270.
-
Product
Online PD Spot Tester
Liona
-
Cable testing and diagnostics with the BAUR liona. Liona is a portable online PD spot tester for measuring and locating partial discharges in cables and switchgear during normal mains operation. Liona lets you test cable systems and electrical equipment online without switching off partial discharge activities, and then generate trend analyses. Even a PD spot test (duration: 5-10 minutes) is capable of reliably assessing the current status of your system.* Automatic PD detection during normal mains operation (without switching off the cable route)* With DeCIFer technology: PD identification based on 500 million measurement results* Precise online PD mapping with PD transponder
-
Product
High Frequency Current Transformer
HFCT Ø 140mm
-
Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).
-
Product
Portable PD Diagnostics System
PD-TaD 60
-
The PD TaD 60 portable PD Diagnostics system is used in combination with a BAUR VLF generator frida for carrying out partial discharge measurement and location.* Comprehensive 360° cable analysis – with parallel partial discharge and dissipation factor measurement* Time-optimised and safe cable condition evaluation* The lightest and most compact PD measuring device up to 60 kVpeak* Developed for portable use on site
-
Product
Spiral Antenna
-
UHF Spiral antenna is a partial discharge sensor designed to receive electromagnetic (EM) emissions from a PD occurring in the monitored asset. It is a broadband antenna with a flat response which makes Spiral antenna suitable in a number of different applications. It has been optimized to operate in a frequency range typical for PD activity and it was designed to provide maximum sensitivity and high gain.
-
Product
Online Partial Discharge Alarm System
PD Annunciator™
-
The PD Annunciator™ unique design consists of a three channels acquisition module paired with sensors of your choice, most commonly TEV and Acoustic or HFCT. With many advancements and innovations, the PD Annunciator™ handles partial discharge monitoring on metallic cabinets using our proven and advanced technologies.
-
Product
Cable Partial Discharge (PD) Spot Testing And Locating
PrecisePD
-
PrecisePD is an on-line PD Spot Testing and PD location system for Cables and Switchgear with advanced signal processing, used for the detection of PD in high noise environments.
-
Product
Ultrasonic Leak Detection Camera
Leakshooter LKS 1000-V.2
-
1st ultrasonic compressed air, gaz and vacuum leak detector with camera. Specialy dedicated to visualize the spots where compressed air is leaking, the LEAKSHOOTER LKS 1000 – V.2 has many other applications such as : steam trap monitoring, bearing monitoring, electrical applications like partial discharge, corona effects, punctured isolators, electrical tracking detection.
-
Product
Partial Discharge
-
Partial discharge (PD) is a local electrical discharge that occurs in imperfections or inhomogeneities. The partial discharge measurement is a so-called “non destructive test” to determine the quality of insulating materials. On the contrary of pure high-voltage test, th test item is not pre-damaged at low PD levels.
-
Product
Real-Time Online Monitoring to Detect and Analyze Potential Partial Discharge (PD) Signals and Insulation Faults using UHF, AE, and HFCT
PDMonitor
-
Power Monitoring and Diagnostic Technology Ltd.
The PDMonitor, which utilizes Ultra High Frequency (UHF), Acoustic Emission (AE) and High Frequency Current Transformer (HFCT) sensors and is designed to conduct real time online monitoring to detect and analyze potential Partial Discharge (PD) signals and insulation faults before they lead to breakdown or catastrophic failure in power assets. The system provides the developing trend of the PD, when occurring, as alarms in real time, thus helping to predict the insulation degradation status of the asset, prevent sudden accidents, and provide an effective database for Condition-Based Maintenance (CBM) of power assets.
-
Product
Multi-Channel PD System Locator
PDiagnostic Series
-
Power Monitoring and Diagnostic Technology Ltd.
The PDiagnostic is a portable system that utilizes Ultra-High Frequency (UHF), Acoustic Emissions (AE), High-Frequency Current Transformer (HFCT), and Transient Earth Voltage (TEV) sensors to detect, analyze, and locate the PD signals in real time for a multitude of medium and high voltage electric power equipment.The multi-channel PDiagnostic system locates PD on power equipment down to a meter by utilizing Acoustic-Electromagnetic Combination Location Technique, Time Difference of Signals’ Arrival (TDOA), Partial Discharge Signals Separation (PDSS), and 3D Positioning Technology with PC software included.The system features advanced PD diagnostic capabilities, automatic PD type pattern recognition, and accurate PD location capabilities. The PDiagnostic is an ideal trouble-shooting tool for your PD programs. Severity is determined and maintenance suggestions are provided accordingly.
-
Product
Field Testing Services
-
Power Monitoring and Diagnostic Technology Ltd.
PMDT offers three levels of testing services both domestically in the US and globally. With the best quality products, complete PD solutions, rich on-site testing experience, experienced partial discharge experts and field engineers, PMDT also provides PDExpert Services -- professional on-site partial discharge detection and location services to help the customers find the potential risks, evaluate the operating status of the electrical assets, and deliver complete and final problem solutions.
-
Product
Insulation Resistance Meter
AMIC-15k1
-
The partial discharge indicator PDI. Diagnosis of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD. Allows to test the electrical durability of the tested object - indication of breaking voltage. The high resistance to electromagnetic interference ensures uninterrupted operation in power plants and near high-voltage transmission lines up to 1200 kV AC and 500 kV DC.
-
Product
Partial Discharge Solutions
-
From software systems to hand-held instruments, we’ve developed industry-leading technology to help you keep on top of ageing assets. Spot the warning signs, including partial discharge, to manage maintenance and make timely repairs.
-
Product
Superior Handheld Partial Discharge Detector
PDStar
-
Power Monitoring and Diagnostic Technology Ltd.
PMDT is proud to present one of our latest innovations, the PDStar. It integrates On-Line Partial Discharge (OLPD) testing and Infrared testing for MV and HV equipment, which combines UHF, AE, Ultrasonic, HFCT, TEV, and Infrared testing technologies. It is applicable for online PD testing, as well as abnormal heating and defect detection on all types of substation equipment. PD amplitude, PRPD, PRPS, and infrared spectrums provide critical data for determining the operational condition of electric power equipment. It connects to the PMDTCloud via Wi-Fi/3G/4G to upload test data, download test tasks, and receive diagnostic results in real time. Another uniquely advanced feature of the PDStar is that it integrates with a 100 MSPS (Mega-Samples per Second) HFCT signal processor, which greatly improves the performance for power cable OLPD testing.
-
Product
Partial Discharge Measurement System
DAC-6021
-
DAC-6021 is a measurement system for testing Partial Discharge of high frequency equipment, power devices, stator coils, etc.Since the system combines Partial Discharge Measuring Instrument (DAC-PD-3) with Testing Corona-free Variable Frequency Voltage Source (DAC-WT-50) and Testing Shielded Chamber, most external noises are removed, and the measurement is safe.
-
Product
Qualification and Quality Control Tests
Techsquare
-
New IEC standards, IEC 60034-18-41 and IEC 60034-18-42, have been issued to define the procedures for testing partial discharge inception voltage and the long-term performance (endurance) of Type I and Type II insulation systems used in rotating machines fed from voltage converters. Voltage impulse generators are required at least to test turn insulation, but they would be recommended for any testing under power electronics supply because of their capability to simulate the real electrical stress conditions. More generally, any type of electrical insulation system when subject to impulsive voltage waveform during life should be carefully evaluated in terms of partial discharge and endurance behaviour. This is why voltage impulse generators able to provide impulses with controlled amplitude and frequency are needed to face this new testing challenge.