Filter Results By:
Products
Applications
Manufacturers
2-wire
resistance measurement method.
-
product
Keysight Dual 4x16 Armature Matrix for 34980A
34932A
The Keysight 34932A module for the 34980A Multifunction Switch/Measure Unit gives you the most flexible connection path between your device under test and your test equipment, allowing different instruments to be connected to multiple points on your device under test at the same time. Dual 4x16, 8x16, or 4x32 configurations 128 2-wire cross-points 300 V, 1 A switch; 2 A carry current Connections to the internal DMM Latching armature relays, with relay counter Expandable via four 2-wire analog buses
-
product
External Temperature for 3-wire PT1000 Probe
TGP-4204
PT1000 probes are available with this logger that will record down to -200C, making them suitable for cryogenic applications. The probes are of 3-wire construction and use class A elements, making them more accurate than their 2-wire predecessors.
-
product
Temperature Sensors
TT420
Features • 2-wire, loop-powered 4-20mA analog output • Attachment probe, sensor, and 2-wire 4-20 mA signal conditioner • Compatible with PLCs, meters, and data acquisition systems • No user calibration • TT420Z 1/4" stainless steel probe • TT420S 1/4-28 threaded stud – screws into any 1/4-28 tap • TT420F mounts onto any flat surface • UL listed, Intrinsically Safe (IS) • Class I, (C, D) and Class II, (E, F, G)
-
product
TB-2676, Ribbon, 100 V, PXI Module Multiplexer Terminal Block
779535-01
Ribbon, 100 V, PXI Module Multiplexer Terminal Block - The TB-2676 features ribbon cable headers that help you access all channels of the PXI-2576 Multiplexer Switch Module. You can use the TB-2676 to configure the 16 banks of 4x1 2-wire multiplexers included with the PXI-2576.
-
product
Switch Mainframe
SW1001
Switch between voltmeter and battery tester while testing. 66 channels max. (2-wire) to 18 channels max. (4-terminal pair). Circuit design friendly for impedance measurements that minimize errors between channels (Effect: 0.01% f.s.*). For BT4560 100 mΩ range, R measurements, and a measurement frequency of 1 kHz. For OCV measurement, internal resistance measurement, and external potential measurement of battery cells. Measure battery modules up to 60 V DC.
-
product
NI TB-2644B Terminal Block for NI 2532B as 1-Wire Dual 8x32 Matrix or 2-Wire 8×32 Matrix Topology Without Column Protection Resistors
782385-09
The TB-2644B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 8x32 or 1-wire dual 8x32 matrix. You can directly connect the TB-2644B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2644B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
product
4 Wire Earth Resistance & Resistivity Tester
4235 ER
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Earth resistivity (ρ) test.● Earth testing at 20Ω, 200Ω, 2kΩ.● Earth voltage measuring : 0-300V AC.● Automatic C spike check.● Automatic P spike check.● 2-Wire test, 3-Wire test, 4-Wire test.● LCM display.● Auto ranging.● Auto power OFF.● Data hold.● 200 measurement results can be saved in the memory and recalled on the display.● Interval between auxiliary earth spikes is 1.0~50.0m.
-
product
External Temperature for PT100 Probe
TGP-4104
This data logger uses an external PT100 probe to record high temperatures. Probes are available to measure up to 300 and 600C. These are listed in the 'You will also need' section. The PT100 probes are of 3-wire construction and use class A elements, making them more accurate than their 2-wire predecessors.
-
product
- RS-485 DIN Rail Mounted Surge Suppressor
Model 8021NX
FEATURES: Fast Response; Automatic Recovery; Up To 20 MBPS Data Rate; DIN Rail Mounted; Triple Stage Protection; Two Wire. The Model 8021NX is a DIN Rail mounted surge suppressor for 2-wire RS-485 circuits used to protect factory data networks, or, any RS-485 network that wants to avail itself of the DIN Rail packaging concept. The Model 8021NX provides common-mode (line to ground) surge protection and differential mode (line to line) protection for balanced networks. All the inputs, outputs and ground connections are via screw terminals located on the top surface of the device.
-
product
Banana-Triax Adapter For 4‑Wire (Kelvin) Connection
N1297B
The N1297 Series is a collection of banana-triax adapters for the Keysight B2900 Series precision source measure unit (SMU). It consists of both 2-wire as well as 4-wire connection requirements.
-
product
Industrial Grade PCI DIO 96 Board
MS 1817
*96 digital input/output lines*Support s all PPI Modes (Mode0, Mode 1 and Mode 2)*5 V TTL/CMOS*Compatible with NI DIO Card*2-wire handshaking capability*Known power-up
-
product
Speed Sensor Intrinsically Safe
ST420
Features • 2-wire, loop-powered 4-20 mA analog output • No user calibration – works right out of the box • Standard and custom measurement ranges available • Reverse-wiring protected • Works with Electro-Sensors magnetic pulser discs / wraps Rugged stainless steel M18x1 housing; UL listed, Intrinsically Safe (IS); Class I, Div I (C, D) Class II, Div I (E, F, G)
-
product
NI TB-2644B Terminal Block for NI 2532B as 1-Wire Dual 8x32 Matrix or 2-Wire 8×32 Matrix topology With Column Protection Resistors
782385-10
The TB-2644B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 8x32 or 1-wire dual 8x32 matrix. You can directly connect the TB-2644B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2644B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
product
PXI High-Density Matrix Switch: 4x64, 2-Wire, 100Vrms/0.5A, Reed Relays
M9121A
The M9121A is a 4x64 full crosspoint switch matrix offering high-density, high-speed signal switching in a single PXI module. The 2-wire matrix allows multiple channels to be connected in a single instance. Any row can be connected to any column, making it ideal for routing instrument signals to the device under test. This 2-wire switch matrix provides the high-speed, long-life reed relays to support signal switching up 100Vrms with 10W maximum power. The 4-wide bus is ideal to route signals between test instruments and the device under test. Choose from the durable connector block or standard cable connections.
-
product
Legacy Liquid Detection Rope Sensor
ENVIROMUX-LDSx-y
For warning of flooding. Detects liquid depth >0.1" (2.5 mm). Minimum puddle: 0.6" (15 mm) diameter. 100% waterproof electronics. Detects any liquid or moisture, except deionized water. RJ45 connector. Voltage Supply: 12VDC. Current Consumption: 20mA. Supports CAT5/5e/6 cable up to 1,000 ft. (305 m). Available water sensor cable (x) lengths: 1/10/50/100/200/400/600/800/1000 feet. Plenum rating: CL2P (UL). Available 2-wire cable (y) lengths: 5/10/20/50/100 feet. Powered by ENVIROMUX-SEMS-16U and SERIMUX-S-x. Regulatory approvals: CE, RoHS. Requires the ENVIROMUX-SEMS-16U and SERIMUX-S-x to operate. Use self-adhesive clips (ENVIROMUX-CLP10-LD) to prevent sensor rope cable from shifing after installation. ENVIROMUX-CLP10-LD includes 10 clips.
-
product
Speed Sensors Dust Ignition-Proof
ST420-LT / ST420-DI
Features • 2-wire, loop-powered 4-20 mA analog output • No user calibration – works right out of the box • Standard and custom measurement ranges available • Reverse-wiring protected Rugged stainless steel M18x1 housing with integral conduit attachment; FM approved, dust ignition-proof. Class II, Div I (E, F, G); NEMA 4X, IP65
-
product
Weather Resistant Surge Protector for RS485 Control & 12VDC Power Lines
SP-RS485-12V-O
Ideal for applications such as video surveillance cameras and access control. Protects sensors running on 22 AWG 2-wire sensor cables or 12VDC power lines against the effects of electrostatic discharge, faulty wiring and lightning. RS485 protection: Stage 1 clamping voltage: ±90V; Stage 2 resistance: 3.3 Ohms; Stage 3 clamping voltage: ±7.5V. 12VDC power lines protection: Stage 1 clamping voltage: ±90V; Stage 2 current rating: 3A; Stage 3: 12V TVS (transient voltage suppression) diode. Screw terminal pairs for RS485 and 12VDC power lines protection. Will also protect two single ended data, analog or control lines. Impact and weather resistant enclosure with locking hinged cover.
-
product
Interface
RAR-cPCI
Available in a range of configurations to match your needs, the RAR-cPCI provides complete, integrated databus functionality for ARINC 429, ARINC 575 and selected 2-wire, 32-bit protocols in a CompactPCI form factor.
-
product
Interface
RAR-PCIE
Available in a range of configurations to match your needs, RAR-PCIE provides complete, integrated databus functionality for ARINC 429, ARINC 575 and selected 2-wire, 32-bit protocols.
-
product
NI TB-2645B Terminal Block for NI 2532B as 1-Wire Dual 16x16 Matrix or 2-Wire 16×16 Matrix Topology Without Column Protection Resistors
782385-11
The TB-2645B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 16x16 or 1-wire dual 16x16 matrix. You can directly connect the TB-2645B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2645B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
product
Temperature Sensors
TT420-LT
Features • 2-wire, loop-powered 4-20 mA analog output • Attachment probe, sensor, and 2-wire 4-20 mA signal conditioner • Integral 1/2" flexible liquid-tight conduit fittings • TT420Z-LT 1/4” stainless steel probe with 1/8 NPT adapter • TT420S-LT 3/8-16 threaded stud probe • FM approved, Dust Ignition-proof • Class II and III, Div I (E, F, G); NEMA 4
-
product
Digital Power Recorder
MPR-601W-01
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Applicable for single phase 2wires and single phase 3wires and *3phase 3wires and 3phase 4wires system*Wide measuring range up to 0~500V/500A*Easy data logging by USB flash memory
-
product
Digital Power Recorder
MPR-601W-02
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Applicable for single phase 2wires and single phase 3wires and 3phase 3wires system*Wide measuring range up to 0~500V/500A*Easy data logging by USB flash memory
-
product
Proximity Sensors
Cutler-Hammer® proximity sensors that deliver the results you're looking for. Choose from photoelectric sensors, 2-wire AC and 3-wire DC inductive sensors, sensors with LED indicators, and more.
-
product
PXIe-2737, 256-Crosspoint, 4x64, 2-Wire PXI Matrix Switch Module
782835-37
256-Crosspoint, 4x64, 2-Wire PXI Matrix Switch Module—The PXIe‑2737 is a high‐density 4x64 PXI matrix switch module designed for routing signals within automated test systems and using electromechanical relays to perform immediate switch operations. It also offers features to monitor the health of deployed systems and plan for predictive maintenance, including onboard relay count tracking, a temperature sensor, and functional and resistive relay self-tests available through the NI Switch Health Center.
-
product
NI TB-2641B Terminal Block for NI 2532B as 1-Wire 8x64 Matrix topology With Column Protection Resistors
782385-04
The TB-2641B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 4x128 matrix. You can directly connect the TB-2641B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2641B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
product
PXI Serial Interface Module
The PXI Serial Interface Module offers a number of options for connecting to serial hardware. You can choose from common serial protocols, such as RS232, RS422, and RS485. The PXI Serial Interface Module also offers various isolation, hyperthreading, and multiprocessor compatibility options as well as 4- and 2-wire transceiver modes for full- and half-duplex communication. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.
-
product
PXI Switch - 4x8 2-Wire Matrix Module
PXI-7931
ADLINK PXI-7931 is a matrix module with 32 cross-point 2-wire relays (DPDT, 2 Form C). The default configuration of the PXI-7931 itself is a 4-group 2x4 2-wire matrix. With the termination board, TB-6231, users could flexibly choose one of the configurations: one 4x8, two 4x4, one 2x16, two 2x8 and four 2x4. Any contact of the PXI-7931 can connect to other contacts, individually or in combination. The PXI-7931 matrix module simplifies the wiring and makes it easy to change the internal connection path. The contact position of the relays can be changed either by direct software commands or by following the instructions previously stored in the on-board scan list. The scan list advances upon the trigger from external measurement devices, such as a DMM. The scan list could also advance when the scan-delay timer expires. In the PXI-7931, PXI trigger functions are supported and software programmable. Multiple modules can therefore be synchronized without additional field wiring.
-
product
Interface RS-485 and RS-422
The RS-485 specification meets the requirements for a truly multipoint communications network, and the standard specifies up to 32 drivers and 32 receivers on a single (2-wire) bus. Some RS-485 transceivers modify the input impedance to allow up to 8× more nodes to be connected to the same bus. Analog Devices offers a wide range of standard RS-485/RS-422 transceivers and iCoupler® isolated RS-485/RS-422 transceivers to suit many applications.