Phantom Loads
generate different current values based upon the current rating of the energy meter under test. 2) standby power of a device turned off.
See Also: Parasitic Drain
-
product
Phantom In-Foil Metal Detector
The Phantom In-Foil Metal Detector is utilized to detect ferrous metals such as iron and steel in products packaged in foil. Available with BSH Extra-Rugged IP69K certified casing for the most resilient performance under harsh conditions such as washdown, the system is able to identify ferrous contaminants despite the presence of aluminum foil wrapping or trays.
-
product
Electronic Loads
PeakTech Prüf- und Messtechnik GmbH
Can be used for important test procedures in quality assurance as well as e.g. testing of power supplies and control units, batteries, fuel and solar cells. For precise load control for various purposes, this device offers load control according to constant voltage (CV), constant current (CC), constant load resistance (CR) or constant power (CP) with a highly precise resolution of 1mW, 1mV, 1mΩ and 1mA. The device also offers additional test modes, e.g. the battery test or the dynamic test. The PC interface and software offer the option of implementing freely programmable test sequences with data evaluation.
-
product
Rack Mounted Load Banks
Traditional commissioning is a daunting task. Since formal system operation doesn’t begin until the system is commissioned, the commissioning team experiences intense pressure to complete the commissioning process quickly. Commissioning can involve high expense and requires staffs from different departmental disciplines to work together. For these reasons data center commissioning has almost uniquely been associated with large data centers (over 20,000 ft2 or 1,858 m2). In the recent past, many data center managers chose to roll the dice and perform little or no commissioning, relying only on start-up data to press ahead with launching the new data center. Given the reality of 24x7 operations, however, the alternative of exposure to major system failures and accompanying downtime is no longer an economically viable option. Commissioning has now become a business necessity. JUNXY series AC & DC rack mounted load banks can be used to introduce heat loads and to allow for simultaneous testing of both electrical and cooling systems.
-
product
Oscilloscope, 350 MHz, 2 GS/s interleaved, 4 CH, 200 Mpts/Ch interleaved, Fully Loaded DSO with 16 Dig Ch MSO
T3DSO2354HD-MS
The T3DSO2000HD series of Bench Oscilloscopes feature 4-channel models with analog bandwidth options of 100 MHz, 200MHz and 350 MHz. The T3DSO2000HD Oscilloscopes use 12-bit high resolution ADCs and a low noise front end which provides an impressive noise performance to cover a wide range of measurement applications. Each model offers a maximum sample rate of 2 GSa/s (interleaved) and a maximum memory depth of 200 Mpts in interleave mode. The MS configured models also include a 16 channel logic probe as standard.
-
product
Economical Single Point Bending Beam Load Cells
ESP SERIES
The ESP Series is a economical, high accurate single point bending beam load cell. It is ideal for OEM applications such as electronic scales and weighing machines. The single point bending beam design is highly resistant to eccentric loading allowing direct mounting to the scale base and weighing platform. The ESP Series features a moisture proof sealant.
-
product
Battery Loading Unit
BLUe
BLUe series Battery Loading Units; portable instruments for controlled & monitored discharge of batteries. It is designed for integrated site discharge test, design & QC test and also for monitoring discharge process of battery bank with connected load. Single autonomous unit having inbuilt display, keypad and wireless communication with PC makes it very easy to use. It comes in different configurations ranging from 12V to 380V discharge voltages and 50A to 300A discharge currents. Various options are available to control & monitor the discharge process. With the help of optional Cell Monitoring Unit - CELLMon, voltage of each individual cell can be monitored & data sent to main BLUe unit and then from main unit to PC via wireless communication. Each BLUe unit is supplied with PC downloading & analysis software for real time monitoring of discharge process.
-
product
Signal Module, ITA, QuadraPaddle, 480 Position, Fully Loaded For Wire Wrap With Anti-Rotation (610 138 122)
510151127
QuadraPaddle modules are molded on .100” (2.54 mm) centers to meet the need for high-density I/O in a compact assembly. Allowing flexible configuration options with standard commercial connectors, QuadraPaddle modules are designed to fit any VPC pin and socket-based Mass InterConnect system. Available in 192 and 480 contact positions, QuadraPaddle modules accept standard .100” (2.54mm) pitch headers, breadboards, and connectors for direct PCB, ribbon cable, and other connections as well as discrete wiring.
-
product
Load Bank
Being the reckoned names in the industry, we offer world-class range of Load Bank that is manufactured with perfection. We offer in different configurations such as Resistive, Inductive, and Capacitive. Our entire product range has high compressive strength and ensures smooth operations. They are durable in nature and are delivered in stipulated time frame.
-
product
DC Electronic Load, Single-Input: 150V, 40A, 250W
EL33133A
The Keysight EL33133A bench DC electronic load provides a single input and a built-in data logger. Provide static or dynamic load test up to 40 A and 150 V. Display results in a meter view or over time using the built-in data logger.
-
product
Signal, Module, Receiver, QuadraPaddle, iCon Series, 160 Position, loaded w/ Twin Female Contacts and Round Posts
510160122
Fully Loaded with Twin Female Contacts and Round Posts (Adapter Pins) (p/n's 610138200 and 610138117).Primary mating module 510161101. (May mate with other ITA modules, as well.)
-
product
Load Banks
PARELO
Amfax introduce the latest generation of load banks we affectionately call PARELO. This range of load banks provides a combination of high performance passive resistive loads along with extreme flexibility of use. This is achieved by our unique FLEXI-phase Switching(TM) technology.. Designed primarily for offering high wattage loads for the aerospace, energy, automotive and transport sectors. PARELO load banks are a cost effective solution for companies requiring high wattage loads when testing their products.
-
product
Signal Converters & Load Cell Signal Converter
Mantracourt provide a range of signal converter modules which take load cell or strain bridge inputs and provide a data output in a variety of bus and protocol formats. Hardware formats include RS232, RS422 RS485, CAN and USB. Signal converter protocols include Industry Standards such as MODBUS, or Mantracourt’s own proprietary protocols which have been optimised for either ease of use (MantraASCII2) or higher speed communications (MantraBus2).
-
product
Robotic Sample Loading Systems
Below you can see examples of two systems using our robotic sample loading system. Many other automated microscopy systems are possible using our components.
-
product
High Power DC Electronic Load
3350G Series(4KW~6KW)
Each 3350G Series module has its own control and display panel, CC / CR / CV / CP /Dynamic modes, also can be controlled via RS232、Ethernet、USB and GPIB interface.
-
product
LUTHER & MAELZER BARE AND LOADED BOARD TEST PROBES
SERIES LMP 60
MechanicalMINIMUM CENTERS: .100 (2.54)FULL TRAVEL: .160 (4.06)WORKING TRAVEL: .107 (2.72)OPERATING LIFE: 1,000,000 cyclesElectricalMAXIMUM CURRENT: 5 amps continuousat working travel, non-inductiveRESISTANCE: At 35 mA test current,35 mOHMS meanMaterials and FinishesPLUNGER: Heat treated berylliumcopper, 24 Kt gold plated over nickelBARREL: Nickel silver, 24 Kt goldplated over nickel
-
product
Battery Load Tester
BT-100
Schumacher Electric Corporation
FOR EVERYDAY DIY USEEasy to operateTest load, battery condition, starter motor draw and complete charging system diagnosis.Works on 6 and 12 volt batteries50 amp load test for 6 volt batteries100 amp load test for 12 volt batteries Tests 6 and 12 volt batteries ─ up to 1000 CCATop-mounted rocker switch for easier operationSuper-grip, heavy-duty color-coded battery clampsEasy-to-read meter ─ accurate and shock resistantBaked enamel, steel case ─ ventilated to keep coolRubber insulated carrying handle ─ for comfort and safety
-
product
Controllable, Programmable Linear DC Source With Load
LAB / SLR
*Linear laboratory power supply*Integrated electronic load*Automatic range selection*Linear regulated DC source with automatic range selection*Built-in electronic load*Short-term peak load operation 240 or 480 watts*Protection against short circuit, overload and overtemperature*Double current / double voltage through "autoranging"*Fast control times approx. 250µ
-
product
Load Cell Amplifier Signal Conditioner with DB9 Connectors
MODEL LCA-9PC
The LCA-9PC Module provides low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-9PC comes with DB9 male and female connectors, which require soldering to user-furnished mating female or male wire connectors. On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film otentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.
-
product
Low Voltage Container Load Banks
Guangdong EMAX Electrical Co., Ltd.
Container load banks are portable, self-contained solutions for testing and maintaining large power systems, designed to be easily transported and deployed in a variety of environments, making them ideal for both temporary and permanent installations.
-
product
Refrigerator Freezing Load M Test Package
CX-MF1
Shenzhen Chuangxin Instruments Co., Ltd.
The Refrigerator Freezing Load M Test Package is made in accordance with the requirements of GB/T8059.2 and GB/T8059.4 standard. The Refrigerator Freezing Load M Test Package is placed in the frozen food storage compartment and chill compartment's performance test.
-
product
500 AMP Carbon Pile Load Tester
CP710
Tests batteries rated as high as 1000 CCA or 160 amp hour. Also tests alternators, regulators, and starters
-
product
Loading Adjustable Drop Tester Machine
CX-DL15A
Shenzhen Chuangxin Instruments Co., Ltd.
Package Impact Drop Testing Machine is used to measure the dropping impact incidence when the package in using, transportation and decorating. Labtone "1G+" project strictly ensure the accuracy. Besides precision plane drop testing, it also can undertake edge and angle test to ensure the complete performance evaluation for the package. During the products handling or transport process, there may be drop/ fall, which results in damage within the products. And this Drop Tester simulates the drop/ fall of a finished product to evaluate the damage. All the rhombohedrons, angles and faces of the products can be tested.
-
product
Oscilloscope, 100 MHz, 2 GS/s interleaved, 4 CH, 200 Mpts/Ch interleaved, Fully Loaded DSO with 16 Dig Ch MSO
T3DSO2104HD-MS
The T3DSO2000HD series of Bench Oscilloscopes feature 4-channel models with analog bandwidth options of 100 MHz, 200MHz and 350 MHz. The T3DSO2000HD Oscilloscopes use 12-bit high resolution ADCs and a low noise front end which provides an impressive noise performance to cover a wide range of measurement applications. Each model offers a maximum sample rate of 2 GSa/s (interleaved) and a maximum memory depth of 200 Mpts in interleave mode. The MS configured models also include a 16 channel logic probe as standard.
-
product
LV Iron Core Line & Load Reactors
Line and load reactors are generally serial-connected to the input and/or output terminals of three phase equipment such as motor speed controllers, inverters and UPS systems. These equipment make use of semiconductor switches such as IGBTs, thyristors, and diodes and therefore create harmonic distortion and high switching over-voltages (dv/dt). Use of such equipment has been becoming more widespread as the technology advances. However, the negative effects of these equipment should not be overlooked.
-
product
QuadraPaddle Signal Insert, ITA, SIM, 4 Position (not Loaded- For Discrete Wiring Only)
510181101
QuadraPaddle Signal Insert, ITA, SIM, 4 Position (not loaded- for discrete wiring only)
-
product
RF Waveguide Load
RF Lambda’s waveguide loads are used at end of an RF signal chain to provide a good 50ohm match and dissipate any RF energy into heat. They are available in a variety of power levels and offer low VSWR.
-
product
Signal, Module, Receiver, QuadraPaddle, 90 Series, 192 Position, Fully Loaded w/ Twin Female Contacts & Square Posts for Wire Wrap (p/n's 610138200 & 610138118)
510150136
Primary mating module 510151105. (May mate with other ITA modules, as well.)
-
product
Programable Power Supply & Programable Electronic Load
EL-820P
*Digital button control and easy operation*High resolution(20mV, 10mA, 0.1W, 0.1Ω)*Overload prevention function*9 sets programmable memory*4 sets real time display*Voltage range: 1V~63V*Current range: 10mA~15A*Maximum power: 200W*Operation mode: CV, CC, CP and CR*Built in USB interface
-
product
Thermocouple, Insert, ITA, SIM, 8 Pos, 3 Slot (not loaded)
510181111
Thermocouple, Insert, ITA, SIM, 8 Pos, 3 Slot (not loaded)Compatible with 410130116, ITA, i2 MX, 22 Slot VTAC/SIM Insert, EMI, and XL version 410130133Not loaded. Thermocouple patchcords need to be purchased separately.





























