Leakage Current Clamps
Measure low current emf surrounding a conductor.
-
Product
Fluxgate 150A Current Sensor
LF03
-
Our LF03 current sensor works with the dynamic Fluxgate measurement technology. It is characterized by its simple, practical design and prevents high temperature drifts. Fluxgate technology uses the phenomenon of magnetic saturation to modulate the measured magnetic field and convert it into an electric field.
-
Product
Digital Eddy Current Displacement Sensor
ZET 7140-S
-
A digital eddy current sensor consists of a primary transducer (eddy current probe) and the ZET 7140-S measuring unit.
-
Product
Current Generator
MIG12100
-
MIG12100 is a current generator with wave shape 8/20 ìs. The exact waveform delivered is a function of the surge generator and the impedance to which the surge is applied. The generator can deliver up to 100kA impulse current supported by 12kV impulse voltage, making it ideal for testing big varistors with high hold-on voltage. Mechanically the MIG12100 consists of two large racks and a separate control console with high voltage output terminals protected by a glass acrylic test cabinet.
-
Product
Current Dataloggers
-
With our selection of current data loggers, you can meet requirements that include the single/split phase, three-phase, neutral, ground current and machine load monitoring. You can also utilize our current loggers for fault current detection, leak identification, and load profiling. We have compact models constructed to be weatherproof. Choose from stand-alone, handheld and clamp-on configurations. Our current data loggers are used in a broad scope of applications, trusted by technicians, electricians and engineers.
-
Product
1000 A AC/DC Navigator Clamp Meter with Temperature
Amprobe ACDC-54NAV
-
The ACDC-54NAV clamp-on power meter offers AC/DC current measurements to 1000 A, AC/DC voltage to 1000 V, temperature capabilities, and wide jaws to handle large conductors up to 1.6″ (40 mm) for high voltage industrial environments.
-
Product
Enclosure, S6, 2U Height, 4 Cable Clamps, 12" Depth
410112712
Enclosure
Enclosure, S6, 2U Height, 4 Cable Clamps, 12" Depth Includes hinged cover and 4 cable clamps for discrete wiring that provide secure strain relief. With the cable clamps open- stiffener bar can be removed allowing installation or removal of cables without unplugging patchcords from the assembly. Housing: Material = .06" Aluminum, Finish = Powder Coat BlackCover(s)/Access Panel(s): Material = .12" Aluminum, Finish = Black Anodize
-
Product
Enclosure, G12x, Front Mount, 4 Cable Clamps, 12" Depth
410112856
Enclosure
Enclosure, G12x, Front Mount, Hinged Cover, 4 Cable Clamps, 12" DepthIncludes hinged cover and 4 cable clamps for discrete wiring. When cable clamps are open- stiffener bar can be removed for installing or removing cables without unplugging patchcords from assembly.Housing: Material = .06" Aluminum, Finish = Powder Coat BlackCover(s)/Access Panel(s): Material = .12" Aluminum, Finish = Black Anodize
-
Product
16-Channel VME Current Source & Analog Measurement Module
V460
-
The V460 is a VME-based versatile source/measurement unit. It includes a programmable constant-current source, a precision programmable gain 16-bit analog-to-digital converter, and a 4-wire, 16-channel analog multiplexer. An internal microprocessor supervises channel scanning according to user loaded parameters, reporting sensor voltage drops or, for selected sensor types, engineering-unit data.
-
Product
High Accuracy 100 Amp Current Probe
HA100
-
The HA100 is a compact clamp-on current probe for smaller loads where compact size is important. Its measurement range is from 0.1 to 100 amps AC and is very small which is ideal for locking inside a crowded electrical panel during monitoring.
-
Product
16-Ch SPST 10A-277VAC High Current
YAV90086
Switch Module
16 power relays SPST Switching up to 2770VA 16A Switching 125Vac 10A Switching 277Vac CAN Control (or Ethernet with Ethernet to CAN Gateway) Drivers dll & VIs available
-
Product
AC/DC Clamp Meter
3800 CL
-
Standard Electric Works Co., Ltd
● Full auto range for V.A and Ω functions.● Data hold function freezes the reading in dimly lit or hard to reach places.● Low battery indication.● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers and motor coils.
-
Product
AC/DC High Sensitivity Clamp-On Current Probe
N7026A
Oscilloscope Probe
The Keysight N7026A is a 150 MHz bandwidth, active current probe for InfiniiVision and Infiniium oscilloscopes. The probe features wide and flat bandwidth (DC-150 MHz), lower noise (<250 µArms), and wide input range (up to continuous 30 Arms or non-continuous 40 Apeak). This enables you to measure down to 1 mA/div, giving you a much more accurate view of your low-level signals.
-
Product
Flexible Clamp Meters
-
TES Electrical Electronic Corp.
Three current ranges. Two output sensitivity measuring instruments. Input protection up to 600V. Suitable for any electrical system. Wide bandwith low phase shift.
-
Product
Clamp Meters
-
Basic functions:AC current: 40/400/1000ADC current: 40/400/1000AAC voltage: 4/40/400/750VDC voltage: 400mV/4/40/400/1000VResistor: 400/4/40/400K/4/40MTemperature: -20 to +750°CFrequency: 10/100/1000Hz/10/100kHz/10MHzDuty cycle: 0.1 to 99.9%Capacitance: 5nF/50nF/500nF/5μF/50μF/200μFSpecial functions:Auto rangingNCVDiodeContinuity buzzerLow battery displayData holdRelative data holdAuto/manual range shiftZeroAuto power-offOverload protectionSampling frequency: 3 times/sMaximum display: 3999Maximum open distance of clamp mouth: 55mmGeneral characteristics:Color: iron gray and orangeNet weight: approximately 274gLCD size: 46 x 32mmSize: 245 x 90 x 33mmPower: 1 x 9V and 6F22Packing content:CartonHandheld bagEnglish manualTesting leadBatteryTemperature probe
-
Product
Device Current Waveform Analyzers
-
The dedicated Current Sensors measure from 100 pA level dynamic current up to 10 A with a maximum of 200 MHz bandwidth. The mainframe acquires the signal from the sensors by a maximum of 1 GSa/s sampling speed and 14-bit and 16-bit wide dynamic range. This combination allows you to measure quite wide range of dynamic current, for example, from standby/sleep state to active state, at a single measurement. In addition, the wide bandwidth and the high speed acquisition enable you to measure high speed pulse response even less than 100 ns previously very difficult with existing instruments.
-
Product
Current Sensors
-
A current sensor measures the flow of electric current to help optimize system performance, safety, and energy efficiency. They allow us to gauge how much power various parts are using. Whether it’s tracking motor loads in EVs, managing power in data centers, or monitoring energy in solar arrays, CTS sensors provide high-accuracy measurements with minimal phase shift.
-
Product
AC Digital Clamp Meter
SK-7601
-
Up to 300A AC., Conductor dia. : Φ27mm max., Compact size clamp neatly fit in your hand., Twist-resistant beaked clamp head., Auto power off., Display hold.
-
Product
Current logger0 to 20mA
TK-4802
-
Supplied with an input cable, this logger can measure current between 0 and 20mA DC and can be connected to many industry standard devices, such as CO2 sensors and current clamps, enabling the logging of a wide range of process parameters.
-
Product
Current Booster
BUX
-
The current boosters allow performing tests up to 2000A, 3000A and 5000A. The option is made of a module, which incorporates a power transformer, which generates a low-voltage, high current output and a metering CT, which measures the output current and sends the metering to eKAM.
-
Product
Split Type AC Current Sensor
CTF-16
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*For AC current and power measurements.*Wide measuring range (AC 0.1~100A).*Compliant with RoHS drective.
-
Product
AC Clamp Meters
-
Power measure of Active power (KW), Reactive power (KVAR),Apparent power (KVA), Power Factor (PF)PF (cosØ), for 3Ø4W, 3Ø3W, 1Ø2W, 1Ø3W.Triple display: KW+V+A easy to read.Recorded each wire parameters of V, A, KW, KVA, KVAR, PF, Hz,total 25 parameters.AC current up to 1000A, AC voltage up to 600V.INRUSH (100mS), HOLD and PEAK functions.MAX and MIN recorded functions.MAX. Cable size: Ø34mm.Auto power off (10 mins), Black-light.EN61010-1, 600V CAT IV, 1000V CAT III.Dimensions: 246mm (H) x 80mm (W) x 43mm(D).
-
Product
1000 Amp AC/DC Digital Clamp Meter
DL6402
-
With inclusion of DC current temperature & capacitance readings, this clamp meter is the ideal all purpose instrument.The slim design combined with the tear shaped jaw makes it an ideal unit for use in crowded panels and tight spaces.The data hold and peak capture function makes this a versatile and cost effective clamp meter.
-
Product
DC BIAS CURRENT UNIT
3265B SERIES
-
To evaluate components at currents up to 125 A the 3265B DC Bias Units are used with either the Wayne Kerr 3255B series of Inductance Analyzers or the 3260B Precision Magnetics Analyzer. When one 3265B/25A or 3265BQ/25A DC Bias Unit is connected to an instrument up to 25 A of DC bias current can be set in steps of 25 mA with one unit. Additional DC Bias Units can be added such that with five units connected in parallel it is possible to set DC bias currents up to a maximum of 125 A DC.
-
Product
AC Clamp Meter
-
Shenzhen UYIGAO Electronic Technology Co., Ltd
Measures AC voltage and current without contacting condutors.
-
Product
Power Absorption Clamp
-
Beijing KeHuan Century EMC Technology Co,.LTD
Frequency Range: 30MHz-1GHz Typical Insertion Loss: 17 dB ± 4 dB Output Impedance: 50Ω Connector: N(f), 50Ω Maximum Current: 30 A
-
Product
ITA, iCon, Extended Cable Clamp
410123115
ITA
This iCon ITA includes an extended cable clamp to accommodate larger cable bundles. The maximum cable bundle area = 1.97 " sq. or a 1.58"/40.13mm diameter bundle. The clamp may be inverted for smaller cable bundles.Please note: This ITA does not offer an increased bend radius that may occur with a larger cable bundle radius. Larger bend radius is offered by the iCon XL, p/n 410123232.
-
Product
High Current Switches
-
Marvin Test Solutions’ switch card portfolio includes matrix, multiplexer, and RF multiplexer configurations. 3U and 6U PXI switch cards feature easy to use, reliable, and integration-friendly D-sub style interface connectors – a feature unique to Marvin Test Solutions PXI switch cards. GENASYS switch cards are compatible with MTS’s family of GENASYS Switching and Switching/Digital Subsystems, featuring integrated MAC Panel SCOUT receivers.
-
Product
High Frequency Current Transformer
HFCT
-
The HFCT is a high frequency current transformer designed specifically for picking up partial discharge signals. It has a split core ferrite to allow retrospective fitting to earth straps without the need for disconnection. The durable body has a hinge and a quick release latch, making use quick and easy. The HFCT is constructed with an aluminium body to provide RF shielding and improved performance in noisy environments.
-
Product
Current Transformers
-
Excellent measurement technology requires high-quality current transformers. The product portfolio comprises a wide range of current transformers for load currents (operating currents) and residual currents (RCM). Different designs cover a variety of installation situations and metrological requirements, and enable retrofitting. AC/DC sensitive measuring current transformers use a special measurement method to detect both AC and DC currents of different frequencies.
-
Product
Lightning Current Generator
-
Shanghai Guantu Technology Co., Ltd.
The lightning wave impulse current generator is an impulse current generator that generates a simulated lightning current waveform . Its working process is as follows: first, the transformer charges the capacitor bank through the silicon pile, when the charging voltage reaches a predetermined value, the spark gap is triggered, and the capacitor is discharged through the total inductance and total resistance of the circuit. When the resistance is greater than or equal to the critical damping value, a unidirectional impulse current wave is generated in the circuit. When the resistance is less than the critical damping value, an oscillating impulse current wave is generated. The magnitude of the impact current amplitude is related to the circuit parameters. When the capacitance value and charging voltage are the same, the smaller the inductance value, the greater the current amplitude. In order to obtain as much current as possible, a pulse capacitor with a small inductance value is usually selected, and the total length of the connecting line should be as short as possible when arranging the main capacitor, so that the total loop inductance value can be reduced as much as possible.