Leakage Current Clamps
Measure low current emf surrounding a conductor.
-
Product
Current Transformer with Open Core
TCP
-
Lifasa - International Capacitors, SA
The TCP series is designed for installations in operation. It has a removable core that allows its connection without interrupting the power supply.
-
Product
Thermistors (Temperature Sensors, Current Control)
-
The resistance value changes in response to temperature changes in the ambient environment or due to heat generated by applied voltage or current.
-
Product
Split type AC Current Transformer
CTF-100T
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*1A output for metering application.*Wire stopper is equipped for the slipping protection.*The special connector is not necessary as the output terminals are provided.*Open circuit protection and nonflammable plastic material.
-
Product
Hipot Current Calibration Load Resistors
HPRS-HIPOT-LOAD
-
The IET HPRS-Hipot-Load is an excellent replacement for the Fluke 5320A-Load Hipot current calibration load resistors. The IET high power resistive load can be used with the Fluke 5320A Multifunction Electrical Tester Calibrator or standalone. It provides a high power and high voltage load to various hipot tester to create the leakage current needed to calibrate various manufactures hipot testers.
-
Product
Handheld 2-D EM current meter with temperature and depth sensor
AEM213-D
-
AEM213-D electro-magnetic current meter with a display unit can provide the 2-D current speeds in real time. The instrument has a depth and a temperature sensor as well as the current sensor, enabling reliable current measurements at the desired depths. The compact and light-weight unit is easily portable, allowing you to use the instrument in a variety of situations.
-
Product
High AC Current Capacitor
LC1/LC2/LC3-RNM
-
Induction Heating Processing Equipment, Electric Current Welding, High Power Resonant Circuits, Motor Controls; Oscillating, Bypass, Coupling circuits, High AC Current applications, High-Frequency AC Filter and Medium Frequency Power applications.
-
Product
Current logger0 to 20mA
TK-4802
-
Supplied with an input cable, this logger can measure current between 0 and 20mA DC and can be connected to many industry standard devices, such as CO2 sensors and current clamps, enabling the logging of a wide range of process parameters.
-
Product
30A, 100MHz High Sensitivity Current Probe
CP031A
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
150 Amps, 10 MHz BW Current Probe - AC/DC , 500 Amp Peak Pulse
CP150
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
DC Bias Current Source
TH1778A
-
Changzhou Tonghui Electronic Co., Ltd.
The instrument adopts a new generation AC/DC superposition test theory to adapt test requirements for high precision and high frequency. The built-in embedded MCU with high-performance can quickly respond to host and slave machine condition or malfunction and make real time indication, which helps improve the work efficiency. The new designed friendly graphical operation interface, included 5-foot control modes and full touch operation provides convenience and efficiency for users. New file management system with easy, prompt and accurate operation can save a group of real-time setting file and 99 groups of user defined setting files. It can provide pushed information indication and cache 2 real-time information. Being provided with two modes of SCPI instruction systems, it is convenient to set up production lines or single machine test. Also, it can connect with any device with serial port and which refer to the SCPI instruction system design of this machine.
-
Product
50A, 50 MHz CURRENT PROBE, BNC, AC/DC, 50A rms, 75A Peak Pulse
T3CP50-50
-
50A, 50 MHz CURRENT PROBE, BNC, AC/DC, 50A rms, 75A Peak Pulse.
-
Product
Water Cooled Laser Power Current Source
-
AMETEK Programmable Power, Inc.
Provides main power directly to the laser diode stacks.
-
Product
MCB Tripping Current Characteristic Test Bench
-
The SCR Elektroniks 12 station MCB Tripping Characteristics Test Bench is optimally designed to verify the Tripping Characteristic of MCBs as per clause 9.10.1 of IEC 60898 (Also mentioned in Indian Standards IS 8828). The bench essentially comprises of Servo Controlled mechanism to set and maintain desired current (against incoming mains fluctuation) and a Micro controller based master controller unit plus timer, which governs the entire sequence of operation making it a stand-alone system once the user connects the MCB and configures the test parameters.
-
Product
Clamp Meters
-
The Delta series consist of clamp meters and clamp CT''s. This meter is basically used where the electric current in the conductor can be measured, without having to make physical contact with it.
-
Product
Current Measurements of PWM or Inverter, AC/DC 1~50A, φ16mm
CTF-50DC
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*AC/DC 1~50A*Current measurements for PWM or inverter
-
Product
Self-testing Static Grounding Clamp
Bond-Rite CLAMP
-
In many branches of the process industries, fires and explosions can result from electrostatic discharge in hazardous areas. Even relatively small sparks have sufficient energy to ignite many flammable vapours, gases and even airborne dusts. In situations, where this risk exists, static grounding (earthing) and bonding clamps are required wherever mobile or portable conductive plant items (such as drums and vessels etc) are used.
-
Product
DC Bias Current Power Supply
TH1775
-
Shenzhen Chuangxin Instruments Co., Ltd.
TH1775 is a DC Bias Current Source (or DC Magnetization Current Source) used for inductance measurement of inductors and transformer windings with DC bias current. Except for constant current output, low additional error and wide frequency response range are important for bias current inductance measurement. High frequency LCR meter could be used, when the frequency response range is wide enough. MPU controlled auto current balance technology is adopted to realize AC+DC current overlap and constant current output from 0 to ±20A. Two TH1775 can be paralleled to supply a maximum current up to 40A.TH1775 permits high frequency measurement up to 1 MHz and can be directly controlled by TH2816A, TH2817A, TH2818 and TH2819. TH1773/TH1775 with its low additional error, wide frequency response range and sweep output function is widely used in DC biased inductance measurement. TH1775 also provides a perfect solution for magnetic material analysis.
-
Product
Current Probe With Hall Effect Technology
CP 35
-
The CP 35 current probe has been designed for use with oscilloscopes respectively for accurate, non-intrusive measurement of AC, DC and complex waveform currents.
-
Product
Clamp Earth Tester with Bluetooth Connection
MET-10X
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
Next clamp-type grounding resistance tester that can connect to a smartphone via Bluetooth and save data on an our cloud server.
-
Product
Clamp type AC Current Sensor/for Low Leakage Current Measurements(ZCT Series)
ZCT-22
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Best sensor for leakage current measurements*Ultra compact size*AC 1mA~100A
-
Product
High Frequency Current Transformers
-
Osborne High Frequency Current Transformers operate at frequencies higher than 50/60 Hertz. Their purpose is to reduce high frequency system currents to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when high frequency current transformers are to be used for power measuring applications.
-
Product
Handheld Digital Multimeter, AC/DC Current, AC/DC Voltage, Capacitance, Resistance, True RMS
72-2995
-
40,000 count industrial True RMS digital multimeter is a highly versatile handheld instrument boasts 5-1/2 digit TRMS accuracy. It provides AC/DC voltage and current measurement, resistance, capacitance, temperature and frequency measurement, displaying readings on a backlit LCD digit and analogue bargraph display. Other features include non-contact voltage detection, continuity and diode test and USB data logging. All this is housed in a rugged overmolded enclosure with carry case, test leads and USB interface cable included.
-
Product
Low Noise Current Preamplifier
SR570
-
Stanford Research Systems, Inc.
The SR570 is a low-noise current preamplifier capable of current gains as large as 1 pA/V. High gain and bandwidth, low noise, and many convenient features make the SR570 ideal for a variety of photonic, low temperature and other measurements.
-
Product
Voltage, Continuity, and Current Tester
FLIR VT8-Series
-
The FLIR VT8-Series are high-quality voltage, continuity, and current testers. They feature an optimized, open-jaw design that can fit into tight spaces and reliably measure large-diameter cables. The VT8-600 carries a CAT III-600 V/CAT IV-300 V safety rating and a 100 A/600 V measuring range, while the VT8-1000 carries a CAT III-1000 V/CAT IV-600 V safety rating and a 200 A/1000 V measuring range. Extensive measurement features make the VT8-Series versatile tools – just one meter can get the job done.
-
Product
HVAC Clamp Meter Kit - ATTPC3, DL479, INF165C, NCV3 W/ AC73 CASE
HVACKIT
-
UEi Test & Measurement Instruments
Everything you need in 1 kit, includes Clamp meter, Infrared thermometer, K-Type pipe clamp adapter, Carrying case
-
Product
CLAMP ON CTS
P50
-
Beijing GFUVE Electronics Co.,Ltd.
The P50 is a general purpose 1000A AC current probe designed for use with DMMs, loggers and other instruments that have a current input. It has a 1000:1 ratio and output of 1mA per amp or 1mV per amp measured in the jaw.
-
Product
AC/DC Current Probe (1-Channel), 3 MHz, 50 UA
N2821A
Battery Probe
As modern battery-powered devices and integrated circuits become more green and energy efficient, there is a growing need to make high-sensitivity, low-level current measurements to ensure the current consumption of these devices is in acceptable limits. The N2821A high-sensitivity probe is engineered to make high-dynamic-range, high-sensitivity measurements to meet today’s challenging current measurement needs.
-
Product
High Speed・High Accuracy Eddy Current Type Digital Displacement Sensor
GP-X
-
Panasonic Industrial Devices Sales Company of America
The inductive displacement transducers of the GP-X Series use eddy current techniques and are particularly noted for their highly accurate measurement at a resolution of 0.02% F.S. with minimal linearity error, a high sampling frequency of 40kHz and low temperature dependence. GP-X Series Sensors are ideally suitable for the highly accurate motion and distance control of metal objects in harsh industrial environments.
-
Product
Resistance Tester With Leakage Current (Loop Current)
GT00WD00ZY
-
*screen display*Double protection insulation*Non-contact measured resistance, safe, fast
-
Product
Calibrator, Calibrated w/Data, Current, 185 mm, 78 mm, 38 mm
72-6694 CAL D
-
The 72-6694 CAL D from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).