Ground Fault
-
product
Variable Power Supply
VS3
The VS-3 power supply is a very convenient portable, non-isolated “variable source” from 0 volts to 150 Vac or 0 volts to 150 Vdc and rated for up to 3 amps, thus the name VS-3. It is comprised of an illuminated voltmeter that reads to the first significant digit, AC variable system output voltage, DC variable system output voltage, logic output voltage and one sense (continuity) contact monitoring points. Banana jacks for connection of test leads are spaced at intervals that allow the use of dual banana test plugs if desired. The VS-3 is protected by two levels of overcurrent protection; AC input, and ground fault protection by a GFCI. All circuitry is housed inside a custom designed case made from 16 gauge steel. An Internal fan dissipates heat buildup and exhaust through louvered side vents built into the case. The carrying handle is designed with a “spring return to rest” position and is padded for comfort. The case has been sized for optimum portability and is balanced from the handle during transportation. The case has a powder coated finish that is scratch, chemical and weather resistant. Rubber padded feet support the case when in the upright position and a convenience receptacle is located on the side of the case. A unique feature of the VS-3 is that it contains “Magnet Packs” on the back of the case. These “Magnet Packs” can support the VS-3 and allow it to “hang” from any magnetic metal surface. The VS-3 can be powered by our UPS system, eliminating the need for an extension cord. The ability to magnetically attach the VS-3 near the source of connection and eliminating the need for an extension cord makes the VS-3 a “must have tool” for technicians.
-
product
Stator Ground Protection Relay
SEL-2664S
Schweitzer Engineering Laboratories, Inc.
Protect high-impedance grounded generators from ground faults at standstill, during startup, and while running with the multisine frequency injection and neutral overvoltage-based protection in the SEL-2664S.
-
product
Ground Fault Protection Monitors
The Earth Fault Resistance Monitor (EFREM) and the Rotor Health Monitor (RHM) provide wireless rotor ground fault and temperature monitoring for generators and motors. The systems replace older slip ring contact ground fault detectors on any synchronous generator or motor.
-
product
E-Z Check® Circuit Tester
61-035
*Tests for correct wiring, open ground, reverse polarity, open hot, open neutral, hot on neutral, hot and ground reversed with open hot in 3 wire, 120 VAC circuits*Simulates ground fault for testing GFCIs*No-slip ergonomic design maximizes comfort*Premium neon lamps prevent false readings*Tough, impact-resistant case*2-year warranty
-
product
E-Z Check® Plus GFCI Circuit Tester
61-051
*Tests for correct wiring, open ground, reverse polarity, open hot, open neutral, hot on neutral, hot and ground reversed with open hot in 3 wire, 120 VAC circuits*Simulates ground fault for testing GFCI*No-slip ergonomic design maximizes comfort*Premium neon lamps prevent false readings*Tough, impact-resistant case*2-year warranty
-
product
CAN/FlexRay/Differential Bus PXI Fault Insertion Switch - 8 Channel
40-200-008
This PXI Fault Insertion module is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This module supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses. Each channel can support up to 0.3A and is rated to handle up to 100V between the wire pairs. The wire pairs have controlled transmission line impedance suited to most differential pair signalling systems, including fast CAN Bus interfaces and RS232. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
product
Field Ground Module
SEL-2664
Schweitzer Engineering Laboratories, Inc.
Add the SEL-2664 Field Ground Module to the SEL-300G or SEL-700G to protect all the critical components in your generator with one comprehensive relay. Or, add the SEL-2664 to the SEL-2664S to complete ground fault protection on both the rotor and stator.
-
product
Phase Rotation Indicator DX2
STB Electrical Test Equipment, Inc
From the company who builds the popular analog ground fault detector comes the newest phase rotation indicator on the market. No other manufacturer offers a phase rotation indicator like STB's DX2 that will read up to 5kV! The phase rotation indicator is used to determine the phase sequence of three-phase voltages. This meter is most commonly used for phasing-in a power line which has supplied power to motors and plants. It is essential for testing departments of public utility systems for laboratory and field testing. The convenient and durable carrying case allows user to safely transport the unit to wherever the job takes them.
-
product
Earth Fault Detector
K-3838
Kongter Test & Measurement Co., Limited
Kongter’s K-3838 earth fault detector is the updated model which is developed to fast detect, trace and pinpoint virtual grounding faults on LIVE DC systems where electrical cables have breakage and current lost to ground. It will save you from long time unnecessary troubleshooting and helps to increase the reliability of your electrical equipments. Our unique technique makes it safe and fast to handle earth fault in DC systems that are working online.
-
product
Bus Bar Protection
BUS1000/2000
The BUS 1000/2000 is a solid state, high speed protectionsystem for the detection of phase-to-phase andphase-to-ground faults on bus bar installations. It can beused to protect high voltage bus bar installations of anyvoltage.
-
product
Service Drop Locator
VM-560
The VM-560 is a general-purpose locator used to detect buried pipe and cable services in a variety of situations. With a 50/60Hz passive power locating frequency and three active frequencies, the VM-560 locator will meet the requirements of those wishing to detect the presence of active power cables and to trace short ranges. The VM-560 transmitter also has the additional frequency of 8kHz Fault-find so it can be used to detect the presence of ground to sheath faults on cable when used with the VM-510 Stand Alone A-Frame fault locator.
-
product
AC Current Transformers
CR Magnetics supplies an extensive line of toroidal current transformers for any need. Our offerings include measuring from 10,000 amps to a few milliamps. This includes ANSI, Commercial, Ground Fault, High Frequency, Wound Primary, DC Immune and Nano Alloy current transformers.
-
product
DC Insulation Monitor
ISM-200
Kongter Test & Measurement Co., Limited
ISM-200 Insulation monitoring system is a high accurate and secure online monitoring equipment for DC system insulation. It is designed for the measurement of different types of ground fault, insulation decreasing, AC signal interruption, DC signal interruption and so on.
-
product
Electric Shock Protection Analysis
60364-4-41 StandardBS 7671 StandardEN 50122 StandardTN-C, TN-S, TN-C-S, TT & IT Earthing TypesElectric shock requirementsLoop impedance and current calculationTouch voltage calculation and evaluationCalculation considers resistance to ground / earthGround Fault Current Interrupter (GFCI) or Residual Current Circuit Breaker (RCCB) or Residual Current Detector (RCD) protectionReports in Crystal Reports and MS Excel
-
product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Dual Channel
40-204-002
The 40-204-002 (PXI) and 42-204-002 (PXIe) are dual channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault. Using the fault bus, switches can simulate a short between both wires or a short to one of two externally applied fault conditions – such as battery supply or ground - via two fault buses.
-
product
Under Ground Cable Fault Locator
Widely used in electrical and power generation sector for testing underground cables in order to detect any fault.
-
product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 4 Channel
40-201-004
This high bandwidth differential fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
product
Variable Power Supply
VS-10a
The VS-10a power supply is a light weight, portable, non-isolated “variable source” from 0 volts to 150 Vac or 0 volts to 150 Vdc and rated for up to 10 amps, thus the name VS-10a. It is comprised of an illuminated voltmeter that reads to the first significant digit, AC variable system output voltage, DC variable system output voltage, logic output voltage and one sense (continuity) contact monitoring points. Banana jacks for connection of test leads are spaced at intervals that allow the use of dual banana test plugs if desired. The VS-10a is protected by two levels of overcurrent protection; AC input, and ground fault protection by a GFCI. All circuitry is housed inside a custom designed case made from 16 gauge steel. An Internal fan dissipates heat buildup and exhaust through louvered side vents built into the case. The carrying handle is designed with a “spring return to rest” position and is padded for comfort. The case has been sized for optimum portability and is balanced from the handle during transportation. The case has a powder coated finish that is scratch, chemical and weather resistant. Rubber padded feet support the case when in the upright position and a convenience receptacle is located on the side of the case.
-
product
Ground-Fault Detectors for Ungrounded Systems
Early detection of ground faults on ungrounded systems allows critical systems to remain online while faults are identified and resolved. By continuously monitoring the system's insulation resistance, Bender's ground-fault detectors can provide early indication of both immediate and trending ground faults before leakage current may be of concern.
-
product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 4 Channel
50-200-004
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
product
Ground Detection and Earth Fault Location Equipment for Ungrounded or Floating DC Systems
ZX3
The ZX3 is a ground fault locator that finds grounds (current leakage) on a battery system positive rail, the negative rail, on both rails simultaneously, in a field device, battery bank or solar array/string, regardless if they are high resistance or low resistance or in a capacitive environment. It also can provide more information about the DC ground than any other equipment available, providing maximum analyzing capabilities.
-
product
Resistance Grounded Systems (HRG/LRG)
Neutral Grounding Resistors (NGRs) are used to limit the maximum ground-fault current. Restriction of fault current lowers hazards and reduces damage done to equipment. High Resistance Grounding (HRG) systems are often used on industrial and critical power applications to maintain system uptime during a first ground fault. HRG systems are also used in tripping applications to help control touch potential on portable loads and improve personnel safety.
-
product
DC Ground Fault Finder
FST-JD200
Foresight Electronics Co., Ltd.
FST-JD200 not only can provide a solution on accurately testing the faults of the indirect-grounding of the direct current system, non-metal grounding, loop grounding, simultaneous grounding of the anode and cathode, balanced grounding of the anode and cathode and multi-point grounding 1.
-
product
Relays, Switches, Sensors
CR Magnetics Sensing Relays and Switches provide a simple method of monitoring electrical properties and alerting a system to a fault or event condition. These products are available with a wide variety of configurations, including time delays, various output styles and logic. From simple proving switches, to fully featured high performance ground fault sensing.
-
product
High Impedance Differential Module
HID
Use the HID module in conjunction with a high-speed overcurrent relay to provide three phase high impedance differential protection for substation busbars of any voltage level. Additionally, it can also be used to protect electrical machines like transformers, generators or motors against restricted ground faults.
-
product
Air Core Neutral Grounding Reactors
Neutral Earthing (Grounding) Reactors, which resist current flow through inductive elements, are single phase reactors generally connected between ground and neutral of transformers or generators in order to control single line-to-ground faults at a desired level.
-
product
Socket Tester
1945
Peaceful Thriving Enterprise Co Ltd
This is a portable 220VAC socket tester to inspect the wiring conditions. The tester also features current variation for simulation of different leaking current. With the current variation, technician is able to test the condition of Ground Fault Circuit Interrupter (GFCI) / Residual Current Device (RCD) easily.
-
product
PXI Single Bus 74-Ch 2A Fault Insertion Switch
40-190B-001
The Single Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
PXI/PXIe Fault Insertion Switch, 64-Chan 2A, N/C Through Relays, Fault Buses on M & U
40-190C-112
The 40-190C-112 (PXI) and 42-190C-112 (PXIe) are fault insertion switches with 64 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
PXI Single Bus 64-Ch 2A Fault Insertion Switch, N/O Through Relays
40-190B-401
The Single Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.