DC Current Sources
-
Product
Power Supplies and Sources
DC Power Supplies
-
DC power supplies are commonly used in electronics design, battery charging, electrical vehicle, research labs and education sectors. UNI-T offers both programmable and non-programmable power supplies with features such as low ripple and noise, constant voltage/current, overload protection, and more.
-
Product
Light Source
pE-300white
-
CoolLED's pE-300white offers intense, broad-spectrum LED illumination for imaging most common fluorescent stains. The pE-300white Light Source can be fitted directly to the microscope or specified with a liquid light guide. The system is a mercury-free alternative that is safer, more controllable, and repeatable than conventional high-pressure gas discharge illuminators. Spectral coverage is from the UV (DAPI excitation) to the Red region (Cy5 excitation). The system is perfect for hospital and regular research laboratory environments.
-
Product
Current Measurements Of PWM Or Inverter, AC/DC 5~100A, Φ16mm
CTF-100DC-U48V
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*AC/DC 5~100A*For current measurements for PWM or inverter
-
Product
Four Quadrant Power Source
PM2010
-
The PM2010 is a four-quadrant power source capable of supplying up to 20 V/10 Amps to a load. The maximum power that may be safely generated is 50 Watts on a continuous basis and 200 Watts peak on a pulsed mode for no more than 100 ms, and a duty cycle of less than 10%
-
Product
DC Blocking L-Band Splitters, RF Power Dividers
-
INSTOCK Wireless Components, Inc
INSTOCK Wireless offers DC-blocking power divider / combiners optimized for L-band power splitting applications. Standard configuration includes DC pass on one port to power a remotely located active antenna. Additional models available blocking DC to all ports. All models pass the 10 MHz reference signal through all ports.
-
Product
PXIe Vector Network Analyzer Source, 1 MHz To 6 GHz
M9389A
Vector Network Analyzer
The M9389A PXIe vector network analyzer source is a component for the M9485A PXIe multiport vector network analyzer. The M9389A configuration includes two PXIe modules (M9310A source output, M9309A synthesizer) and its control is provided through the M9385A software front panel (SFP). The M9485A provides a true multiport VNA with up to 12-ports in one chassis and up to 24 ports in two chassis.
-
Product
DC Load Banks
Custom DC Units
-
Mosebach Manufacturing Company
Mosebach has been building DC load banks for over 30 years. We have a wide range of custom-designed units. Please give us a call at 1-866-629-4328 to discuss your needs.
-
Product
Programmable DC Electronic Loads
SDL1000X/X-E Series
-
SDL1000X/SDL1000X-E series Programmable DC Electronic Load has a 3.5 inch TFT-LCD display, a user-friendly interface and superb performance specifications. The SDL1020X/SDL1020X-E models feature an input range of 150 V/30 A 200 W while the SDL1030X/SDL1030X-E have an input range of 150 V/30 A 300 W. The SDL1000X series leads with measurement resolution of 0.1 mV/0.1 mA and the base SDL1000X-E series resolution is 1 mV/1 mA and adjustable current rise times from 0.001 A/μs~2.5 A/μs. For remote communication and control, the SDL series includes RS232/USB/LAN interface types. The SDL1000X series delivers stability over a wide range of applications and can meet all kinds of testing requirements. including: Power, battery/handheld device design, industry, LED lighting, automotive electronics, and aerospace.
-
Product
PXI Switchable-Input Programmable Step Attenuator Module, DC to 50 GHz
M9169E
Attenuator
The M9169E is a 3-port PXI programmable step attenuator module with a switchable path for a calibrator signal (cal input) into the input of a signal analyzer to improve amplitude accuracy. The M9169E has 0.03 dB insertion loss repeatability throughout the operating life of up to 5 million cycles per section. Its excellent attenuation accuracy across a wide operating temperature range ensures precise measurements.
-
Product
RF Reference Sources
-
The 27 GHz 96270A and 4 GHz 96040A Low Phase Noise Reference Sources are designed specifically for RF calibration, featuring a calibration-oriented interface, precision signal level and attenuation, high signal purity and precision low distortion modulation. Both instruments simplify the process of RF calibration by reducing the amount of equipment and simplifying the calculations required.
-
Product
Adapter, APC-7 to Type-N (m), DC to 18 GHz
11525A
Contact Adapter (ITA)
The Keysight 11525A is a general purpose grade, APC-7 to type-N male adapter.
-
Product
Current Measurements Of PWM Or Inverter, AC/DC 10~200A, Φ24mm
CTF-200DC-U24V
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*AC/DC 10~200A*Current measurements for PWM or inverter
-
Product
DC to Synchro and Linear DC to Resolver Converters
ST-LDS & ST-LDR
-
Computer Conversions Corporation
ST-LDS and ST-LDR Prefix - Linear DC to Synchro and Linear DC to Resolver Converters On PCB with Mounting Track having Screw-Terminal Block for ease of wiring
-
Product
Electronic DC Load, 500V, 16A, 400W
LDH400 Series
-
Versatile solution for direct testing of dc power sources and PFCsConstant current, resistance, conductance and power modesWide voltage and current range, 10 to 500V and 0 to 16A400 watts continuous dissipation at 28°C (360W at 40°C)High resolution and accuracy for level settingBuilt-in transient generator with variable slewCurrent monitor output for waveform viewingVariable drop-out voltage for battery testingHigh resolution backlit graphic LCD with soft key controlAnalogue remote control of levels and TTL control of on/off and transient switchingFront and rear input terminalsLoad inputs rated to CAT II (300V)Full bus control via USB, RS232 and LXI compliant LAN interfacesGPIB Option
-
Product
Medical Leakage Current Tester
2675Y
-
Shenzhen Chuangxin Instruments Co., Ltd.
The 2675Y Medical Leakage Current Tester Series Is The Test Equipment Used For Measuring Continuous Leakage Current And Patient Auxiliary Current Of Medical Electrical Equipment.It Designs And Products According To The GB9706.1_2020 (IEC60601-1:2012) .And The Test Circuit (MD)Input Impedance To Simulate The Body Impedance,It Accord With The Requirements Of GB9706.1-2020 (IEC60601-1:2012),The Test Current Can Run Up To 5A,And Provide Users With An Isolation Power Supply Which Adjustable Output Voltage For 0~250V Continuously Of The Basic Capacity Configuration For The 500VA And Provide Another 110% Voltage Source Of The Maximum Rated Voltage.It Can Satisfy The I,II, Various Types Of Equipment Test The Earth Leakage Current,Shell Leakage Current,Patient Leakage Current,Patient Auxiliary Leakage Current Under Normal Condition And The Single Fault.
-
Product
DC Power Supply
PW-3063R
-
*Use Toroidal Transformer. Low EMI & High EMS.*Triple output, 0-32V/0-6A X2 and 5V/3A .Max. 400Watts*Tracking operation. Max. output 64V/6A on tracking series or 32V/12A on tracking parallel.*4 display, Green LED shows Voltage and Red LRD shows Current. Easy to read.*Compact design. G.W. 9Kgs only. Easy to handle.*The resolution of PW-3063R as high as 0.1v and 0.01A.*Very low Ripple & Noise, less than 0.4mVrms. Very suit for precise measurement.
-
Product
Multiport Electronic Calibration Module (ECal), DC To 9 GHz, 6-ports
N7562A
-
A series of multiport ECal that cascade-able up to 36-ports which makes it possible to calibrate a wide frequency range from DC up to 9 GHz without making numerous connections during calibration process. Ideal for multiport measurement application with VNA in such as high-volume PA/FEM, massive MIMO antenna or high-speed digital interconnect test applications
-
Product
Light Sources
-
These external units provide illumination which is transmitted to the viewing instrument by a light guide cable, and then through the scope via the integral fiber bundle to the viewing tip.
-
Product
IP67 DC Blocking Splitter Combiner
PD5023
-
INSTOCK Wireless Components, Inc
PD5023 is an IP67 outdoor, weather resistant, DC blocking, two way, RF broadband, 50 ohm, power divider, power combiner furnished with N type coaxial connectors. The passive Wilkinson design passes RF and the 10 MHz reference signal through both ports while blocking DC current. This configuration is typically used in combining applications to prevent passing DC to the sum and adjacent ports. Max voltage rating at the DC blocked ports is 50 VDC. All wireless band applications in the frequency range from 698 to 2700 MHz are covered with best in class RF performance. The RoHS compliant PD5023 is a bidirectional device capable of 40 W max microwave input power levels in both power splitter and combiner apps. See 2 way power divider input rating tables for additional power handling info.
-
Product
AC and DC Electronic load
63800 series
-
The Chroma 63800 Loads can simulate load conditions under high crest factor and varying power factors with real time compensation even when the voltage waveform is distorted. This special feature provides real world simulation capability and prevents overstressing thereby giving reliable and unbiased test results. The 63800's state of the art design uses DSP technology to simulate non-linear rectified loads with its unique RLC operation mode. This mode improves stability by detecting the impedance of the UUT and dynamically adjusting the load's control bandwidth to ensure system stability. Comprehensive measurements allow users to monitor the output performance of the UUT. Additionally, voltage & current signals can be routed to an oscilloscope through analog outputs. The instrument's GPIB/RS232 interface options provide remote control & monitor for system integration. Built-in digital outputs may also be used to control external relays for short circuit (crowbar) testing.
-
Product
Programmable Step Attenuator DC~50GHz, 0~115dB Att.
-
The programmable step attenuator achieves step attenuation over a wide frequency band. It features high attenuation accuracy, excellent repeatability, low insertion loss, and long service life. Its primary applications include controlling the amplitude of signals entering systems, regulating output signal power in systems, and adjusting impedance matching between signal sources and loads. It is widely used in various broadband spectrum analyzers, broadband vector network analyzers, broadband synthesized signal sources, noise figure test sets, and diverse microwave automatic test systems.
-
Product
HCAI-1 High Current Arc Ignition Tester
HCAI-1
-
The HCAI-1 High Current Arc Ignition Tester is according to IEC 60950-1:2001, BS EN 60950-1:2001, BS 7002:2000, GB 4943.1-2011
and UL746A, IEC60947.1: 1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-2008 and other standards required simulated safety test project. Parts and components of insulating materials or other solid combustible materials that are prone to flame spread in electrical and electronic equipment may ignite due to proximity or contact with electric arc, causing electrical fire and endangering the reliable operation of equipment and personal safety. -
Product
Regenerative DC Electronic Load
IT8300 Series
-
ITECH newly launched IT8300 Regenerative DC Electronic Load, it not only can simulate various load characteristics, but also can feed power back to grid without pollution. IT8300 series unique regenerative function can convert the absorbed DC power into AC power and feed it back to local grid.
-
Product
High Current / High Voltage Pulsers
DEI Division
-
Berkeley Nucleonics Corporation
is optimized for high impedance capacitive loads, driving extraction grids and deflection plates, and pulsing or gating power tube grids. It generates an output voltage of 6,000 volts with rise and fall times less than 60ns, with very flat voltage pulses from 160 nanoseconds to DC into a capacitive load.
-
Product
Current Generator
MIG12100
-
MIG12100 is a current generator with wave shape 8/20 ìs. The exact waveform delivered is a function of the surge generator and the impedance to which the surge is applied. The generator can deliver up to 100kA impulse current supported by 12kV impulse voltage, making it ideal for testing big varistors with high hold-on voltage. Mechanically the MIG12100 consists of two large racks and a separate control console with high voltage output terminals protected by a glass acrylic test cabinet.
-
Product
Balance Thermocouple Power Sensor, DC To 18 GHz
N8481S
Power Sensor
The Keysight N8480S Series Balance Thermocouple Power Sensors are intended to be used as measurement standards for RF power. They are suitable for use in a microcalorimeter-based primary measurement standard and as a secondary or reference measurement standard. The new balance thermocouple power sensors offer a broad frequency range DC up to 18/50 GHz, high maximum input power of +20dBm, fast measurement speed/settling time as well as ease of maintenance.
-
Product
Digital Source Capture Unit
DIO2
Capture Unit
The DIO-II module is a multimode digital source and capture unit. In Low Speed Mode it provides a 20-bit parallel or 24-bit serial I/O capability running at speeds up to 50 MHz. In High Speed Mode, the DIO-II provides a 16-bit parallel I/O capability up to 200 MHz. In both Modes, the Clock is generated by a low jitter PLL source that is capable of generating clocks from 320 kHz up to 1 GHz.
-
Product
Bench/System DC Power Supply With PowerFlex Or PowerFlex+ Regulation
QPX Series
-
Wide range of voltage/current combinationsUp to 80V and up to 50A within the same power envelopeLow output ripple and noise of <3mV rms at full powerHigh setting resolution of 1mVAnalogue control interfaces for voltage and currentBench or rack mounting, front and rear terminalsUSB and LAN (LXI) interfaces with GPIB optional (QPX600DP, QPX1200SP and QPX750SP)
-
Product
DC TO 40 GHz
MDHC Series
-
Smiths Interconnect's spring loaded High Frequency Micro-D Coax Connectors MDHC offer low VSWR of 1.5:1 (typical) up to 40GHz (max mated pair), maximum overall diameter of 0.125" fitted into low-profile micro-D housing, constant 50 Ohm airline impedance.
-
Product
Source / Measure Unit (SMU) Modules, N6700 Power System
System
The Keysight N6780 family of source/measure units (SMUs) provide advanced features and precise control and measurements of voltage and current down to the microampere and nanoampere regions. They provide stable, glitch-free output voltage and current during high-speed load changes, fast output modulation, and high-speed measurements of both voltage and current simultaneous.





























