Standard Resistors
Resistor having a known resistance value.
-
product
Current Sense Resistors
Panasonic Industrial Devices Sales Company of America
Panasonic offers a wide variety of Thick Film Current Sense Resistors (ERJ-B1, B2, xB, xBW, xCW) in a large range of case sizes and in wide terminal types for high solder joint reliability. The ERJ Series of Current Sense Resistors offers power ratings up to 2W with low ohmic ratings ranging from 5mΩ to 10Ω. Panasonic’s Thick Film Current Sense Resistor portfolio offers a more cost effective option with high reliability. Panasonic has a wide line of case size options ranging from 0402 to 2512 in conventional terminal and 0612 to 1020 for wide terminal.
-
product
The Industry Standard for Automated Network Protocol Validation
IxANVL
Keysight Network Applications and Security
With Ixia’s IxANVL (automated network validation library), you can quickly and effortlessly access a vast array of protocol libraries and utilities to validate protocol compliance and interoperability. Easy to use thanks to an enhanced GUI and flexible test-automation capabilities, IxANVL delivers a number of key advantages. By emulating large, multinode networks, it not only reduces costs—it also leads to more efficient testing and faster product-release times. And extensive and thorough automated testing increases your confidence in product quality.
-
product
Standard Voltage 50 Pin D-Type Connectors
The connectors below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
product
PCI Precision Resistor Card 3-Channel, 2.5Ω To 102kΩ
50-297-140
The 50-297 provides a simple solution for applications requiring accurate simulation of resistive sensors. The 50-297 is available in a variety of resistance ranges and resolution capabilities that meet the needs of most functional test systems. It is particularly well suited to applications such as the testing of engine controllers where resistive sensors provide information on parameters such as temperature.
-
product
PXI/PXIe High Density Precision Resistor Module
42-297A-155
The 40-297A-155 (PXI) and the 42-297A-155 (PXIe) are 3-channel programmable resistors with a range of 3 Ω to 43.8 MΩ. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
product
PXI Precision Programmable Resistor Modules
Pickering's PXI precision programmable resistor modules feature high setting resolution with excellent stability and accuracy through the use of innovative switching networks and software correction techniques. This also means all resistance values can be set - there are no missing values due to switch resistance or resistor tolerance. These modules are ideal for sensor emulation applications that require very fine adjustment and also have the capability of being set as open or short circuit to simulate faults in cabling systems. The range includes modules specifically designed for RTD and strain gauge simulation.
-
product
Light Sources & Calibration Standards
Photometric Solutions International Pty Ltd
We offer a range of specialised and customised light sources for various applications.The spectral range goes from 200 nm to 40 µm.
-
product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39H-5.4
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
product
PXI/PXIe High Density Precision Resistor Module
42-297A-146
The 40-297A-146 (PXI) and the 42-297A-146 (PXIe) are 3-channel programmable resistors with a range of 2.5 Ω to 5.82 MΩ. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
product
Hydrogen Frequency & Time Standard
CH1-1007
Hydrogen frequency and time standard Ch1-1007 is designed to generate and reproduce precision, highly stable, spectrally pure frequency and time signals. Main areas of application: – in metrology when transferring the sizes of units of frequency and time, including as part of mobile measuring complexes; – in radio astronomy when conducting scientific research; - in radio navigation when working as part of automated measuring systems and complexes.
-
product
Series Standard HV Capacitors
PMT10000
Power Measurement Technologies Inc.
High voltage, low dissipation factor, gas-filled Standard Capacitors for indoor use in a laboratory or production environment. A three terminal design configuration allows accurate measurements of capacitance and dissipation factor (tangent delta) with little or no effect from test lead or stray capacitance.
-
product
Standard 1.32 (37.40) - 4.50 (128.00) Battery Probe
CP-2LB-6
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 69Full Travel (mm): 1.75Recommended Travel (mil): 59Recommended Travel (mm): 1.50Overall Length (mil): 236Overall Length (mm): 6.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
product
Calibrated Diffuse Reflectance Standards
Diffuse reflection calibration standards in synthetic ODM and ODMP material
-
product
Standard Helmholtz Coils
Helmholtz Coils are ideal for the measurement of Rare Earth (Samarium Cobalt, Neodymium) and Hard Ferrite permanent magnet materials (materials which exhibit a relative straight line demagnetization). Our standard Helmholtz Coils are for use with fluxmeters. The Helmholtz Coil measures the magnet sample as a single magnetic moment provided that the longest dimension of the magnet sample is less than one-third (1/3) the diameter of the coil system. By definition, the magnetic moment per unit volume is the intrinsic magnetization of the sample. With our calibrated Helmholtz Coil and Integrated Fluxmeter – and given the volume of the permanent magnet sample – the intrinsic open circuit operating B (Bdi) can be measured.
-
product
PXI Programmable Load Resistor Modules
Pickering's PXI programmable load modules offer a solution to applications requiring higher power handling capabilities, up to 15W in a single PXI slot. High Power Potentiometers can easily be formed by using two channels of Programmable Load Resistors in series, using the unconnected terminals as the A and B connections and the link between the two channels as the wiper connection.
-
product
Resistors for Calibration of Current Measuring Systems and Sensors/Transducers
ChenYang Technologies GmbH & Co. KG
Is designed and made according to the Standard JB/T8225-1999 for DC resistors used in laboratory and electrical engineering.By using full closed structure and automatictemperature control it ensures resistor good long-term stability and small temperaturecoefficient. This DC resistor is very suitablefor DC current measurement and calibration of current measuring systems and current sensors. The maximal measuring current is 100A with measuring accuracy of ±0.02%
-
product
Standard Type
FD-10
This device supports the measurement of rivers, Agricultural water, Sewage systems, Other channels and facilities.
-
product
Standard 1.17 (33.20) - 4.50 (128.00) Battery Probe
CP-2LB-8
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 88Full Travel (mm): 2.25Recommended Travel (mil): 78.7Recommended Travel (mm): 2.00Overall Length (mil): 315Overall Length (mm): 8.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
product
Impedance Standards and Calibrators
Impedance Calibrator is to replace countless single value RCL standards with one calibrator that can switch between the standards like a CD changer in your car. The calibrator contains stable and temperature independent resistance standards, partial capacitance standards and partial inductance standards, simulated by RC T-type passive network. Calibration values of both complex parameters of partial standards are displayed on large LCD screen in preselected pairs of parameters as well as voltage, current and frequency readouts from built-in test signal meter. OPEN and SHORT reference positions are available as well.
-
product
Nanolattice Standards for Analytical Instruments
The NanoLattice™ (NLSM) 100 nm pitch standard utilizes gratings with near perfect periodicity to calibrate magnification and scan linearity of Electron and Atomic Force Microscopes (AFM). Make the grade, with the highest quality pitch standard of its kind available.
-
product
Viscosity Standards
Brookfield Viscosity Silicone and Oil Standards provide a convenient, reliable way to verify the calibration of your Brookfield laboratory viscometer/rheometer.
-
product
Motor Control Resistors
Post Glover specializes in motor control resistors — the most popular use of our resistors — for severe duty applications. Our resistors make it possible to start and stop extremely powerful electric motors — such as those on cranes, compressors, and pumps — with safety and precision.
-
product
Standard Directional Gyroscopes
4000B-series
The 4000B is our standard air-driven directional gyro. As the aircraft turns left or right, gears on the sensing unit and dial shaft translate this rotation into rotation of the instrument’s vertical dial. Left turns produce clockwise dial rotation and right turns produce counter-clockwise rotation. The gyro is controlled by a heading selector knob located on the lower left of the instrument. Pressing and turning the knob first disengages the dial shaft and then resets the dial to a new heading, which results in a new course indication. Releasing the selector knob re-engages the dial shaft. The on-course position of the pointer is always at the top of the azimuth circle (0° on the dial with the aircraft headed north).
-
product
The Standard R&D Wafer-Lifetime Tool
WCT-120
Best available lifetime measurement accuracy. Measure lifetime and surface recombination for a wafer of any quality or crystallinity.
-
product
Standards and Regulations
Is your organization ready to engage in the world of autonomous and electric vehicles?
-
product
Automatic Voltage Regulating Relay- Standard Model
NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.
-
product
Standard 2.90 (82.20) - 5.40 (153.00) Switch Probe
TSP157-F200-1
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 20Test Center (mil): 157Test Center (mm): 3.99Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 984Overall Length (mm): 25.00Switch Point (mil): 67Switch Point (mm): 1.70
-
product
PXI/PXIe 15W Programmable Resistor Module
42-254-034
The 40-254-034 (PXI) and 42-254-034 (PXIe) are programmable resistor modules with 1 channel which can be set between 2Ω and 102kΩ with 2Ω resolution The 40-254 range provides a simple solution for applications requiring up to 15W of power handling per channel.
-
product
PXI High Density Precision Resistor Module, 9-Channel, 2Ω to 122Ω
40-298-112
The 40-298-112 is a high density programmable resistor module with 9 channels which can be set between 2Ω and 122Ω with 0.5Ω resolution The 40-298 range provides a simple solution for applications requiring accurate simulation of resistive sensors. The 40-298 is available in a variety of resistance ranges and resolution capabilities that meet the needs of most functional test systems.
-
product
Standard 0.81 (23.00) - 4.50 (128.00) Battery Probe
CP-059-026
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 57Full Travel (mm): 1.45Recommended Travel (mil): 40Recommended Travel (mm): 1.00Mechanical Life (no of cyles): 100,000Overall Length (mil): 221Overall Length (mm): 5.61





























