Lightning Generators
Generate high voltage surges.
-
product
Lightning Current Generator
Shanghai Guantu Technology Co., Ltd.
The lightning wave impulse current generator is an impulse current generator that generates a simulated lightning current waveform . Its working process is as follows: first, the transformer charges the capacitor bank through the silicon pile, when the charging voltage reaches a predetermined value, the spark gap is triggered, and the capacitor is discharged through the total inductance and total resistance of the circuit. When the resistance is greater than or equal to the critical damping value, a unidirectional impulse current wave is generated in the circuit. When the resistance is less than the critical damping value, an oscillating impulse current wave is generated. The magnitude of the impact current amplitude is related to the circuit parameters. When the capacitance value and charging voltage are the same, the smaller the inductance value, the greater the current amplitude. In order to obtain as much current as possible, a pulse capacitor with a small inductance value is usually selected, and the total length of the connecting line should be as short as possible when arranging the main capacitor, so that the total loop inductance value can be reduced as much as possible.
-
product
HPA General Purpose Probes
General Purpose Spring Probe contact solutions are designed for high volume testing and feature the industry-proven Pylon line. General-purpose probes are offered in both replaceable and non-replaceable options.
-
product
Crown, Four Point, Alternate 0.78 (22.00) - 3.70 (105.00) General Purpose Probe
HPA-0L-1
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
product
HD Arbitrary Waveform Generator,8 Ch,250 MHz,16 bit,128Mpts/Ch,6 Vpp output,AFG/AWG, Wave Sequencing
T3AWG3258
HD Arbitrary Waveform Generator,8 Ch,250 MHz,16 bit,128Mpts/Ch,6 Vpp output,AFG/AWG, Wave Sequencing.
-
product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2C30
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
SPA General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
product
200MHZ, 2.4 GSa/S, 20 Mpts, 2 Channel, 20 Vpp Function/Arbitrary Waveform Generator
T3AFG200
Teledyne Test Tools T3AFG5 and T3AFG10 series Function/Arbitrary Waveform Generators are a new family of low cost, high performance, single channel Function / Arbitrary waveform generators offering a high level of functionality and an excellent specification at a very competitive price point.
-
product
Pyramid, 3-Sided Chisel 30°, Alternate 0.78 (22.00) - 3.70 (105.00) General Purpose Probe
HPA-0T-1
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
product
PXI/PXIe Arbitrary Generator Family
PXA(e)72xx
The arbitrary waveform generators of the PXA72xx family feature 16-bit resolution at a maximum sample rate of 200 ms per second. Furthermore, the devices can directly output voltages up to 30 V (or ±15 V).
-
product
PXI-5421, 43 MHz Bandwidth, 16-Bit PXI Waveform Generator
779176-01
43 MHz Bandwidth, 16-Bit PXI Waveform Generator—The PXI‑5421 is a 43 MHz arbitrary waveform generator capable of generating user-defined, arbitrary waveforms and standard functions including sine, square, triangle, and ramp. This arbitrary waveform generator can generate signals from -6 V to +6 V and uses direct digital synthesis (DDS) to precisely generate waveforms. The PXI‑5421 also features advanced synchronization and data streaming capabilities.
-
product
P2664 General Purpose Probes
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
product
Alternate 1.00 (28.00) - 2.00 (57.00) General Purpose Probe
P2663G-1R2S
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
product
Alternate 2.52 (71.00) - 6.50 (184.00) General Purpose Probe
EPA-3L5-1
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Flat, Alternate 0.78 (22.00) - 3.70 (105.00) General Purpose Probe
HPA-0F-1
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
product
Alternate 0.50 (14.00) - 2.50 (71.00) General Purpose Probe
P2662BG-2V2S
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 68Full Travel (mm): 1.73Recommended Travel (mil): 50Recommended Travel (mm): 1.27Overall Length (mil): 575Overall Length (mm): 14.60
-
product
Ultra High 4.18 (119.00) 11.70 (332.00) General Purpose Probe
EPA-3G-2
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1T
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-9
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
product
A-S General Purpose Probes
Current Rating (Amps): 2Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 30Full Travel (mm): 0.76Recommended Travel (mil): 20Recommended Travel (mm): 0.51Overall Length (mil): 230Overall Length (mm): 5.84Rec. Mounting Hole Size (mil): 38Rec. Mounting Hole Size (mm): 0.97Recommended Drill Size: #62 or 0.97 mm
-
product
Ultra High 4.09 (116.00) - 10.00 (283.00) General Purpose Probe
EPA-2C40-2
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
Ultra High 4.09 (116.00) - 10.00 (283.00) General Purpose Probe
EPA-2G30-2
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
Alternate 6.00 (17.00) - 2.50 (71.00) General Purpose Probe
P2662AG-1R2S
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
product
Ultra High 4.18 (119.00) 11.70 (332.00) General Purpose Probe
EPA-3D-2
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 6.13 (174.00) - 16.00 (456.00) General Purpose Probe
EPA-5B
Current Rating (Amps): 8Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,420Overall Length (mm): 36.07
-
product
Alternate 2.52 (71.00) - 6.50 (184.00) General Purpose Probe
EPA-3T-1
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Ethernet/LXI generatorNETBOX 16 Bit Arbitrary Waveform Generator - up to 125 MS/s on 4 Channels, up to 80 MS/s on 8 Channels
DN2.656-08
The generatorNETBOX DN2.65x arbitrary waveform generators (AWG) is a general purpose multi-channel AWG with outstanding dynamic performance. The series includes LXI units with either four, eight or 16 synchronous channels. The large onboard memory can be segmented to replay different waveform sequences.
-
product
PXI-5412, 20 MHz Bandwidth, 1-Channel, 14-Bit PXI Waveform Generator
779176-03
20 MHz Bandwidth, 1-Channel, 14-Bit PXI Waveform Generator - The PXI‑5412 is a 20 MHz arbitrary waveform generator capable of generating user-defined, arbitrary waveforms and standard functions including sine, square, triangle, and ramp. This arbitrary waveform generator can generate signals from -6 V to +6 V and uses direct digital synthesis (DDS) to precisely generate waveforms.
-
product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1G
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
product
Lightning Surge Generator
CDN-5809
Shanghai Sanki Electronic Industries Co., Ltd.
CDN-5809 signal line/data line coupling decoupling network, unshielded asymmetric communication line suitable for surge pulses and ringing wave pulses, designed according to Figure 9 of the new standard IEC61000-4-5.Ed3. It also satisfies vibration Figure 9 of the ring wave standard IEC61000-4-12Ed2 requires unshielded asymmetry. According to the characteristics of the line, the pulse coupling can be realized by gas discharge tube, capacitor, diode and other different methods.
-
product
3GHz Single Channel Portable Signal Generator
LS3081P
The LS3081P, 3GHz Single Channel RF Analog Signal Generator, offers industry leading performance, in a modern tablet like design that can be used as a benchtop or portable unit. The LS3081P features exceptionally fast switching speed, superior signal integrity and purity and all the necessary modulated signals for analog communication systems. The LS3081P was designed to offer excellent performance and meet today’s most demanding applications, whether in the lab or out in the field.