Integrating Spheres
Uniformly scatter or diffuse light rays.
See Also: Goniophotometers, Spectroradiometers
-
Product
Integrating Spheres
-
All our spheres can be coupled to our high performance spectroradiometer systems for UV-visible-IR spectral power distribution measurements yielding full colour information including colour rendering indices, chromaticity co-ordinates, colour temperature, etc. Alternatively precision photometric detectors can be fitted for direct total lumen output measurements.
-
Product
LED Uniform Light Sources
-
Integrating sphere light source with LED illuminants (white, RGB-colored, NIR). Options available like variable output control and monitor detectors. We are experts in providing customer specific systems. Please contact us for all possible solutions and finding your perfect solutions. E.g. for EMVA 1288 Standard.
-
Product
Integrating Sphere
-
The standard test temperature is 25, but high power lamps such as HID lamps and LED outdoor luminaires will produce a lot of heat during the test, thus the temperature inside the integrating sphere can not meet the requirements of IEC standards. Lisun Group designed the Constant Temperatured Integrating Sphere which allows the lamp was tested in a constant air temperature.
-
Product
LED Tester0.3m-2m Integrating Sphere
CX-8000
-
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
Product
Uniformity Calibration Standards
-
Integrating sphere light sources with halogen lamps or LEDs for generating luminous fields with uniform luminance distribution. Traceable calibrations of luminance or spectral radiance in the wavelength range from 250 nm to 2500 nm.
-
Product
Conversion Kit for Kelvin Holders
KC-4
-
Integrating Spheres are essential tools for photometric research laboratories & lamp / luminaire manufacturers. To derive the best results from Integrating Sphere Photometry, precision lamp holders are necessary
-
Product
*High Speed, Multifunctional Integrating Spheres
-
Multifunctional integrating spheres enable simultaneous measurement of multiple laser parameters including:*Power*Pulse Characteristics*Spectrum
-
Product
Integrating Sphere
-
The simpler way to measure the total luminous flux of lamps and luminaires is to use an integrating sphere photometer system. It is a device to perform spatial integration of flux optically, thus the total luminous flux can be measured with one fixed photometer head and measurement can be instant. An integrating sphere photometer is calibrated with a total luminous flux standard lamp. A test light source is measured by comparison to a standard lamp calibrated for total luminous flux.
-
Product
Integrating Spheres
-
Instrument Systems Optische Messtechnik GmbH
Determination of radiant power or luminous flux from light sources with the aid of integrating spheres is one of the most important procedures in photometry. Designed as a hollow sphere whose inner surface is coated with a diffusely reflecting material, the integrating sphere ensures complete integration and mixing of light radiation. This is then output on a detector port for measurement.
-
Product
Integrating Sphere Based Spectroradiometer Systems
-
Spectroradiometer systems with integrating sphere for the measurement of UV-VIS-NIR spectral radiant flux (W/nm) and luminous flux (lm) and chromaticity metrics.
-
Product
0.3M Integrating Sphere For Leds Luminous Flux Test
CX-0.3S
-
Shenzhen Chuangxin Instruments Co., Ltd.
Thesystem are composed of integrating sphere, spectroradiometer and computer to determine the spectroradiometric and colorimetric parameters, e.g. spectral power distribution, chromaticity coordinates, correlated color temperature, color rendering index, color tolerance, color difference, luminous flux, current, voltage, wattage, etc.
-
Product
CCD Spectroradiometer Integrating Sphere Compact System
LPCE-3
-
LPCE-3 is a CCD Spectroradiometer Integrating Sphere Compact System for LED Testing. It is suitable for photometric and colorimetric measurement of luminaries such as LEDs, LED luminaires, Energy-saving lamps, Fluorescent lamps, HID lamps (high voltage sodium lamps and high voltage mercury lamps) and CCFL. The measured data meets the requirements of CIE, EN and LM-79 clause 9.1 for the measurement of photometry and colorimetry.
-
Product
Standard Light Source
SLS-50W
-
OSRAM Standard Lamp to calibrate the spectrum and luminous flux with Lisun Lab certification. The data can be traced NIM. The Standard Lamp Source is used to calibrate the integrating sphere system. The different size of Integrating Sphere should choose the right power of standard lamp source.
-
Product
High Precision Spectroradiometer Integrating Sphere System
LPCE-2(LMS-9000)
-
LPCE-2 is an Integrating Sphere Spectroradiometer LED Testing System for identifying the performance of single LEDs and LED lamps. LED’s quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE127-1997, IES LM-79-08 and IES LM-80-08, it recommends to using an array spectroradiometer with integrating sphere to test SSL products. The LPCE-2 system is applied with a CCD Spectroradiometer (LMS-9000B or LMS-9000A) and worked with A molding integrating sphere with testing holder base function which will be more circle and the test results will be more accurate than the traditional integrating sphere.
-
Product
Adjustable High Frequency Reference Ballast
HCS-109A
-
HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)
-
Product
Integrating Sphere Light Sources
-
Integrating sphere light sources with LED based or continuous broadband emission spectrum for use as luminance standards for camera calibration, for the determination of veiling glare, for the adjustment of night vision devices and much more. Diameters in the range from 50 mm to 500 mm with options like monitor detector, signal output control by manual and remote apertures and much more.
-
Product
Integrating Spheres
IS-*M
-
• Diameter: IS-0.3M (φ0.3m)、IS-0.5M (φ0.5m)、IS-1.0M (φ1.0m)、IS-1.5M (φ1.5m)、IS-1.75M (φ1.75m)、IS-2.0M (φ2.0m). Other sizes can be designed according to the customer’s request. • The painting of integrating spheres is according to CIE Pub.No.84 (1989) • Material: Pure barium soleplate (BaSO4) • BaSO4 coating: ρ(λ)≥0.96 (450nm~800nm) and ρ(λ) ≥0.92 (380nm~450nm) • Fine diffuse reflection: Reflectanceρ≈0.8 and accuracy of ρ (λ) <1.5% • Build-in lighting holder position: The vertical is for E40, E27 and so on. The horizontal is for T5/T8/T12 tubes. The side assistant opening is for lighting fixtures • Auxiliary lamp position has been built-in. Auxiliary lamp and Auxiliary lamp device are optional • Power cable and socket has been build-in, it is convenient to power the testing lamp • Two photo detector ports, one optical fiber port and temperature sensor hole are built-in • The traditional integrating sphere is assembled by several pieces, Lisun Group developed A Molding Technology to produce the integrating sphere. A molding integrating sphere will be more round and the test results will be more accurate than the traditional integrating sphere
-
Product
Broadband Light Meters With Integrating Sphere
-
Broadband light meters with integrating sphere for measuring laser power (W) and luminous flux (lm).
-
Product
General Purpose Integrating Spheres
-
General Purpose Integrating Sphere Systems are designed to spatially integrate radiant flux in order to measure optical radiation. The spheres can be coupled with a sensor to create radiometers, photometers, or spectroradiometers in order to measure the total geometric flux emanating from a light source or the flux density of an illuminated area. Additionally, these sphere systems can be used to measure the output of high power lasers and laser diodes or to measure the reflectance and transmittance of materials.
-
Product
Integration Spheres
-
Offers a wide range of integration spheres (0.25m to 3 m diameter) and spectrometer options, application-specific modules as well.
-
Product
Integrating Sphere Solutions
-
An integrating sphere is a light collector which takes advantage of physical geometry to homogenize any radiation being emitted inside by relying on a high-reflectance coating material. Depending on the wavelength range the end user using a sphere with, different coatings have different advantages based on the application.
-
Product
UV-VIS-NIR Spectrophotometer
UV-3600i Plus
-
UV-3600i Plus, the Multi-purpose large-sample compartment and the Integrating sphere attachment also feature three detector, enabling the high-sensitivity measurement of solid samples. LabSolutions UV-Vis is a next-generation Shimadzu UV control software pursuing efficiency of analysis. LabSolutions UV-Vis software with easy-to-use is included as standard.
-
Product
Passive Component Integration
-
Integrate passive optical components of your choice such as WDM couplers, splitters, band-pass filters, PM beamsplitters and circulators. PXIe and benchtop models support SMF, MMF and PMF.
-
Product
Passive Component Integration - MATRIQ
-
The Passive is a highly customizable benchtop accessory that can integrate the passive components of your choice for convenient storage and integration into your test set up.We can customize the Passive module with a wide range of passive components: WDM couplers, splitters, circulators, band-pass filters, PM beamsplitters, MUX, DeMUX and more.Our spec sheet contains a selection of popular configurations.Please contact us to discuss your specific requirements at sales@quantifiphotonics.com.
-
Product
Passive Component Integration - PXIe
Passive Series
-
The Passive PXIe module is a highly customizable PXIe module that can integrate the passive components of your choice.We can customize the Passive module with a wide range of passive components: WDM couplers, splitters, circulators, band-pass filters, PM beamsplitters, MUX, DeMUX and more.Our spec sheet contains a selection of popular configurations.Please contact us to discuss your specific requirements at sales@quantifiphotonics.com.
-
Product
Azure Sphere
-
Comprehensive IoT security solution—including hardware (crossover microcontroller), OS, and cloud components for IoT device security—to actively protect your devices, your business, and your customers. With billions of new devices connected each year, it's more important than ever to secure yours. Help protect your data, privacy, physical safety, and infrastructure with Azure Sphere. It's built on decades of Microsoft experience in hardware, software, and cloud services to provide a turnkey security solution for IoT devices.
-
Product
Sphere Spectrophotometers
Ci6x Family
-
The Ci6x family of sphere spectrophotometers from X-Rite are convenient handheld instruments that easily adapt range of workflows and accurately color measure a broad array of materials.
-
Product
Integrated
-
Columbia Research Laboratories
Columbia's Integrated Accelerometers are completely self-contained vibration measuring systems having a built-in amplifier within the housing. Low output impedance allows operation directly into standard readout equipment without auxiliary signal conditioning. This type of accelerometer must be powered by a constant current power supply like Columbia's model 5421.
-
Product
12.5 mm Test Sphere Probe
CX-12.5
-
Shenzhen Chuangxin Instruments Co., Ltd.
The rigid sphere (12.5 mm) from Autostrong is designed and manufactured to perform the test specified in many standards (IEC 60335, IEC 60065, IEC 60745, IEC 61029, IEC 60950) to prove the degree of protection for the first characteristic numerals 2 (IP2X) .Its is designed to meet the requirements of international safety regulatory agencies such as UL, DNV, IMQ, BVSQ, ITS, IRAM , CSA, VDE, DIN , INMETRO.
-
Product
Signal Integrity Products
-