Standard 1.00 (28.00) - 3.20 (91.00) General Purpose Probe
P2550-0
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,453Overall Length (mm): 36.91Rec. Mounting Hole Size (mil): 126Rec. Mounting Hole Size (mm): 3.20Recommended Drill Size: #30 or 3.20 mm
-
Product
Ultra-low Noise Phase Inverter - Buffer
WMA-IB-LN
-
The WMA-IB-LN can be used to double the output voltage of two high voltage amplifiers by driving them in bridge mode, or as high impedance input buffer while maintaining precision and ultra-low noise. The WMA-IB-LN model has been designed specifically for the Falco Systems WMA-200 high voltage amplifier. Two WMA-200 amplifiers combined with one WMA-IB-LN provide unprecedented noise performance and output voltage range.
-
Product
Standard - 5.00 (142.00) - 8.30 (235.00)
P3325-1
-
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 66Recommended Travel (mm): 1.68Overall Length (mil): 645Overall Length (mm): 16.38
-
Product
Standard 1.50 (43.00) - 4.00 (114.00) Bead Probe
BTP-25F-4
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
MicroPhase I LRP - Dual Phase Voltage Detector / Phase Comparator
MP1-02P
-
Hachmann Innovative Elektronik
MicroPhase I LRP is an easily operated phase comparator, dual voltage detector and maintenance tester. Its automatic, thorough self-test ensures reliable function. The permanently enabled interface-testers warn against defect interfaces. Thanks to the "LRP-switch" the threshold value can be lowered from 2,5 µA (HR, MR, LR and LRM) to 1,0 µA (LRP).
-
Product
UV/VIS/NIR Spectrophotometer Calibration Standards
-
As the world's foremost spectrophotometer reference standard manufacturer, we have a dedicated staff and years of experience to back up our products. Our solid state UV/VIS/NIR reference standards are the most stable on the market and remain in spec long after many other manufacturer's standards go bad. Relying on our proprietary nano-deposition technology, you can rest assured that our solid-state standards will produce steady readings for years to come on your machines.
-
Product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-7
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3E
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1H-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3J
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Phasing Tester
-
Phasing testers are used on grounded and ungrounded alternating current systems to check high-voltage fuses, test for correct phase connections and test for the absence of high voltage on de-energized lines or apparatus.
-
Product
Multiple High Resistance Standard
MHS
-
*1 MEGOHM TO 1 TERAOHM*FULLY GUARDED*HIGH IMMUNITY FROM AMBIENT TEMPERATURE CHANGES*TRANSPORTABLEOhm-Labs' new Multiple High Resistance Standard maintains state-of-the-art resistance at levels above 1 megohm.
-
Product
Standard 0.50 (14.00) - 2.00 (57.00) Non Replaceable General Purpose Probe
A-A-S-C
General Purpose Probe
Current Rating (Amps): 2Average DC Resistance lower than (mOhm): 30Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 30Full Travel (mm): 0.76Recommended Travel (mil): 20Recommended Travel (mm): 0.51Overall Length (mil): 310Overall Length (mm): 7.87Rec. Mounting Hole Size (mil): 31.5Rec. Mounting Hole Size (mm): 0.80Recommended Drill Size: #68 or 0.79 mm
-
Product
Phase Sequence Indicators (Contact Type)
862 PR
-
Standard Electric Works Co., Ltd
● Two functions in one unit: open phase and phase sequence detection.● Neon light indicators.● Large size alligator clips for easy clipping onto switch- boards terminals.● Checks a wide range of 3-phase power sources.● Ideal for installing conveyor lines, pump systems and interconnected drivers.● Waterproof design, protection class : IP24.● Special test leads length are available on request.
-
Product
Standard Mechanical Calibration Kit, DC To 9 GHz, Type-N, 50 Ohm
85032F
-
The Keysight 85032F calibration kit contains precision 50 ohm type-N standards used to calibrate Keysight network analyzers. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 9 GHz.
-
Product
Phase Locked Laser System
SolsTiS-Phase Locked
-
The phase locked SolsTiS system is primarily designed for use in atom interferometry and quantum computing where Raman transitions are commonly used, although we can tailor the setup to other applications. The system provides extremely low phase noise and high output powers. Full control over the system is provided through our easy to use Ice Bloc user interface.
-
Product
Ultra Low Noise, Rubidium Frequency Standard.
A10-M
-
Frequency Referencing, Calibration, Standards Lab, Production Test for Oscillator Manufacturers. A very high stability LOW NOISE 10MHz Rubidium Reference, primarily for production test of quartz oscillators and RF instrumentation frequency referencing. This industry standard 2U rack-mount instrument has a long heritage and ongoing production life for this latest 2009 version that features RS232 monitoring and control of the DPLL, locking the Ultra Low Noise OCXO to the Rubidium. Damping and Bandwidth is controlled by integrator digital gain, proportional digital gain, pre-filter order and subsample rate. Eight values of user selected bandwidth are available.
-
Product
General Purpose Benchtop XRD System for Phase I.D. and Phase Quantification
-
In a move to bring lab-quality performance to the manufacturing floor, Rigaku introduces the MiniFlex XpC, a manufacturing-optimized powder diffractometer for fast and accurate quality control measurements. It is extremely easy to operate using Rigaku’s new EasyX quality control software, which requires minimal clicks to run. A minimal interface means there will be no accidental error variance from operator to operator. The MiniFlex XpC can be configured with a conveyor belt or robot for automated sample processing and collaboration with other instruments. With an 800 W X-ray source and a short-diameter goniometer, the system has the performance of a lab unit, and thus can greatly improve throughput for quality control measurements.
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1H-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Flat, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0F
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25I-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Additional Products: Standard Voltage 50 Pin D-Type Cables - Connector to Connector
-
The connector to connector cable assemblies below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
Product
Standard 1.24 (35.00) - 2.94 (85.00) Battery Probe
CCA-006
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 78Full Travel (mm): 1.98Recommended Travel (mil): 40Recommended Travel (mm): 1.02Overall Length (mil): 669Overall Length (mm): 16.99
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1Z-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1T
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39L15-5.4
ICT/FCT Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
Product
Standard 2.00 (57.00) - 4.00 (113.00) General Purpose Probe
P2757G-1R1S
General Purpose Probe
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2E
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64