Spectral Response
sensitivity of sensor to a specific wavelength over a spectral band.
See Also: IPCE
-
product
Spectral Response SystemsQuantum Efficiency SystemsIPCE Measurement Systems
QE system provides electronics and software designed for fully automated measurement of external quantum efficiency of solar cells. All systems include probes and a fixed plate sample stage for samples up to 150 mm x 150 mm. The main system components include: custom designed software, measurement electronics, and computer system (Windows 8 operating system). The measurement involves focusing monochromatic light to a spot on the device under test, then accurately measuring the photon flux and current from the test cell. The system utilizes a dual beam configuration with lock-in detection, providing an absolute accuracy of ±3%. The QE system uses a grating monochrometer with silicon/InGaAs/Ge detectors. The system includes automatic order sorting filters and two light sources for monochromatic illumination (a Xenon- arc lamp and a halogen lamp). A single lock-in amplifier is used to measure both the reference detector and test device. The main system comes with all the hardware needed to measure quantum efficiency, a fixed plate sample stage and probes.
-
product
Extreme Low Power Detector Laser Power Meters
11XLP12
11XLP12 extreme low power detector is best suitable for low power im both the µW and mW regimes with very low thermal drift. Featuring broadband flat spectral response, minimal thermal drift and a noise equivalent power as low as 1 µW the 11XLP12 is ideally suited for measuring any pulsed or CW low power laser.
-
product
Detector Testing
CI Systems' Optical Test benches are especially built to test many types of detector arrays used as the sensors of a camera, from visible to far infrared ranges. With CI Systems' expert know-how, these test benches can be tailored to a customer's design requirements. MTF, spectral response, crosstalk, NETD and sensitivity are some of the basic parameters that can be tested with CI's Optical Test benches during the design, manufacturing and integration of detector arrays.
-
product
SiTek UV PSD
The UV PSD is a detector optimized for use in the UV wavelength region 200-400 nm, although its spectral response reaches up to 1100 nm. The sensitivity in the UV region (200-400 nm) is extremely high. The UV-PSD has the same outstanding specifications as the standard SiTek PSD.
-
product
Complete Testing Solutions
System includes a lamp and monochromator for a tunable light source, which is coupled to a high sensitivity source meter with measurement software. This user-friendly system is the most powerful Spectral Response system currently on the market, but its true power is the ease of upgrading from the base PTS-1 to the more powerful PTS-2-QE (Quantum Efficiency) or PTS-3-CPM (Constant Photocurrent Method). Designed for researchers who have limited budgets but want to start work immediately, this allows the ability to do baseline studies until additional funding for the full QE or CPM system becomes available.
-
product
Illuminance Probe
LP471PHOT
Photometric probe for measuring the ILLUMINANCE, spectral response according to the photopic curve, class B according to CIE N° 69, cosine correction diffuser.
-
product
Spectral Responsivity
Standard detectors calibrated in spectral responsivity and spectral irradiance. Traceable calibrations in the wavelength range from 200 nm to 1800 nm.
-
product
EQE/Photon-Electron Conversion Testing
Enlitech offers different solutions for incident photon-electron conversion testing systems. The available systems include IPCE, PV External quantum efficiency (PV-EQE), Internal Quantum Efficiency, Spectral Response (SR), Highly-sensitive EL-EQE. There are over 1,000 SCI papers cited Enlitech‘s systems to provide reliable experimental data for significant scientific publication. The Highest PV-EQE sensitivity and EL-EQE both reach 10-5 % (7 orders). They can be utilized to PV conversion efficiency, HJT/ PERC/TOP-CON current-loss analysis, Organic PV charge-transfer-state and Perovskite PV trap state measuring, and Organic PV and Perovskite PV Voc loss analysis.
-
product
Power Detector Laser Power Meters
11PMK-H5
Fast, Small Size, Flat Spectral Response, Full NIST-Traceability, High Damage Threshold: 36 kW/cm² to 45 kW/cm², Personal Wavelength Correction™, Low profile, Air and Water cooled, Energy mode, Effective aperture diameter 19 mm (area 2.84 cm²)
-
product
Light Sensor
NaPiCa
Panasonic Industrial Devices Sales Company of America
Visible light sensor (Silicon Photo IC) that detects light and converts into electrical current. Consists of a photodiode and built-in amplifier. Optical filter provides spectral response similar to human eye sensitivity. Applications include: LCD Backlight Control, Commercial and Residential Lighting Brightness Control, Security Lighting.
-
product
UV Photodiodes
Active area from 0.06 mm² to 36 mm² and quadrant photodiodes for position detections. Spectral response for broadband UV or filtered for UVA, UVB, UVC or UV-Index. Various entrance optics and housings options available (TO or SMD). Our own SiC photodiode chip production since 2009 also available with VUV sensitivity. PTB (German equivalent of NIST or NPL) measured high radiation hardness. 350°C high temperature stable photodiodes available. Photodiode application guide.
-
product
Power Probes
RkP-400 Series
The RkP-400 Series probes consist of a compact head containing the detector and a preamplifier housed in a separate enclosure. The external dimensions of all the 400 Series Probes are the same, with identical detector planes, allowing for easy interchange of probes in an experiment. The heads have both ¼-20 and M6 tapped holes, a built-in 1” (25mm) filter holder, and a side-mounted BNC connector. Probe specific data, including spectral response curves and calibration dates, is stored in the preamplifier for access by the instruments.
-
product
Radiometer Spectral sensitivities precisely adapted to the human skin
UVS-E-T
The UVS-E-T has a spectral response that is adapted to the erythemal (sunburn) action spectrum of the human skin (CIE 1987 weighting). Hence, this radiometer collects information of medical and public concern: UV Index, UV Erythemal dose and dose rate.
-
product
Ultra-Micro Spectrometers
UltraMicro
spectro-module is constructed by a new invented technology and can provide high optical resolution and fast spectral response. The optical engine is very simple and optimized for the spectrometer. The optical bench is very rigid and stable for measurement system. The compact size is very flexible for system integration.
-
product
Spectral Response (Spectral Sensitivity) Measurement
It is used to measure the spectral response (spectral sensitivity) of photoelectric conversion devices (photodetectors / sensors) such as silicon photodiodes and CCD · CMOS image sensors . Measurement in the broadband wavelength region can be performed with low stray light.
-
product
Ambient Light Sensors
Renesas' ambient light sensors optimize display backlighting, enhance energy efficiency, and improve user experience with ultra-low light sensitivity, low power consumption, and precise spectral response. Our offerings include light-to-digital sensors with IR blocking filters and I2C interfaces, and light-to-analog solutions integrating photodiodes and amplifiers. Designed for automotive, industrial, and medical applications, these sensors deliver reliable performance even in demanding environments.
-
product
Image Sensor Characterization Systems
Image Sensor QE and Spectral Responsivity Characterization
-
product
Solar Cell Characterisation
The PVE300 permits the determination of device spectral responsivity (from which may be determined EQE), and, having performed measurements of sample reflectance (and transmittance where required) the determination of IQE.
-
product
Hybrid Picosecond Photon Detectors
HPPD Series
technology.The HPPD is our latest development in TCSPC detector technology that combines the benefits of conventional PMT design (wide spectral response and large active area)with the advantages of solid state APD technology (good detection efficiency, negligible after-pulsing and exceptional temporal resolution). Hybrid detectors are becoming thefirst choice for FLIM and short lifetime determination.
-
product
Custom Detectors
Besides the described types Inphora can supply detector-filter combinations with parameters matching the customer's special requirement, with different sized housing, without housing. If the application determines the detector's spectral responsivity, we can achieve that with a filter designed exactly to the specifications. CCD cameras with unusual spectral sensitivity functions can be matched with filters to obtain CIE tristimulus response or photopic response. Similarly, photmultiplyers can be matched also with INPHORA filters. When determining parameters for a custom detector-filter combination several details have to be considered:
-
product
Solar Energy, PV Monitoring
Apogee silicon-cell pyranometers feature a monocrystalline silicon-cell detector that has the same spectral response as a PV module. The sensors quantify shortwave radiation being harnessed as electricity.
-
product
UV A Radiometer
UVS-A-T
The UVS-A-T has a broad spectral response optimised for precise measurements of atmospheric UV-A irradiance.
-
product
Sensors
Renesas' light and optical sensors are best in class for ultra low light sensitivity, low power consumption, ideal spectral response, and easy to use simple output algorithms. We offer a full suite of optical sensors to suit your application requirements and budget.
-
product
Digital Lux Meter
PM-3
Is a compact, lightweight & easy to use Illuminance meter. The sensor is a highly stable silicon photo diode having a wide measuring range. Its spectral response is closely matched with the CIE relative photopic luminosity curve by multi-element glass filters. The sensor is also cosine corrected for true response at variable incidence angles.
-
product
Energy Probes
RjP-400 Series
The RkP-400 Series probes consist of a compact detector assembly, or head, and a preamplifier housed in a separate enclosure. The external dimensions of all the 400 Series Probes are the same, with identical detector planes, allowing for easy interchange of probes in an experiment. The heads have both ¼-20 and M6 tapped holes, a built-in 1" (25mm) filter holder, and a side-mounted BNC connector. Probe specific data, including spectral response curves and calibration dates, is stored in the preamplifier for access by the instruments.
-
product
Radiometer Spectral sensitivities precisely adapted to the measurement task
UVS-B-T
Compared to the spectral response of the UVS-E, the UVS-B-T has a sharper cut-off at the transition from UV-B to UV-A. This feature reduces the UV-A contribution to the radiometer output and permits the highest possible correlation to atmospheric UV-B irradiance.
-
product
Light Meters
LXP-2
The digital light meter is a precision instrument used to measure illuminance (Lux, footcandle) in the field. It is meet CIE photopic spectral response. It is fully cosine corrected for the angular incidence of light. The illuminance meter is compact, tough and easy to handle owing to its construction. The light sensitive component used in the meter is a very stable, long-life silicon photo diode and spectral response filter.
-
product
Pyrgeometer Low Temperature dependence of sensitivity
CGR 4
CGR 4 pyrgeometer is an instrument for the highest quality scientific measurements. The specially designed meniscus dome provides a 180 field of view with negligible directional response error. A hard-carbon coating on the outside of the dome smoothes the spectral response and provides extra protection to the silicon surface.
-
product
Luminance Probe
LP471LUM2
Photometric probe for measuring the LUMINANCE, spectral response according to the photopic curve, angular field 2°.
-
product
Frequency Response Function
FRF
FFT Spectral Analysis. Frequency Response Function (FRF) is a commonly used measurement type of the Dynamic Signal Analyzer. FRF is defined as the ratio of response i.e. acceleration, velocity, or displacement with respect to the excitation force which is the reference.