Transfer Standards
-
product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-3
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2G40
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
Automatic Battery with Filters with Standard Contactors
BATLVF120
Lifasa - International Capacitors, SA
Accessories: Differential protection
-
product
Standard RF Power Sensors
Coaxial Dynamics "Standard" line of RF Power Sensors provide DC currents proportional to the forward and reflected power flowing through the line. All models are designed to drive a 30A, 1400-Ohm meter, or provide approximately 100 millivolts across a 5K load.
-
product
Standard And Custom Targets
Santa Barbara Infrared manufactures a wide range of targets for visible, and infrared/FLIR electro-optical testing. These targets complement our complete line of Visible and IR test products. Our targets are designed to function with one of SBIR’s target wheels. Utilizing a variety of manufacturing techniques, including conventional machining, photochemical etching, electro-deposition, electrical discharge machining (EDM) and laser cutting. SBIR targets are manufactured to exacting mechanical tolerances. SBIR manufactures all of the targets specified by MIL-STD-1859 and the Tri-Service Guide for thermal imager testing.
-
product
Viscosity Standards
Brookfield Viscosity Silicone and Oil Standards provide a convenient, reliable way to verify the calibration of your Brookfield laboratory viscometer/rheometer.
-
product
Standard Gain Horn Antennas
Linear polarized Broadband Horn Antenna (Brass with Plastic mounting body) for Receive and Transmit Applications.
-
product
Standard -1.44 ( 41.00) - 4.50 (128.00)High Current Probe
HCP-13B
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.00 (28.30) - 5.40 (153.00) Battery Probe
BIP-10
Current Rating (Amps): 5Average Probe Resistance (mOhm): 30Resistance Remark: Probe Resistance Steel: 30 mOhms, Gold plated: 100 mOhmsTest Center (mil): 260Test Center (mm): 6.60Full Travel (mil): 157Full Travel (mm): 4.00Recommended Travel (mil): 126Recommended Travel (mm): 3.20Overall Length (mil): 591Overall Length (mm): 15.00
-
product
Programmable S/R Standard & Simulator
5300
NAI’s 5300 Synchro/Resolver Standard & Simulator is a laboratory-grade, programmable instrument. This model can be used as a true Synchro/Resolver standard for calibrating and testing Automatic Test Equipment (ATE) for Calibration/Metrology Labs, and for Engineering Design and Production Test environments. It can also be used to measure Angle Position Indicators (API) and Synchro-to-Digital converters for static or dynamic characteristics. This model also may use an external reference waveform.
-
product
Standard Voltage 50 Pin D-Type Cables - Connector to Connector
The connector to connector cable assemblies below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
product
Hydrogen Frequency & Time Standard
CH1-1007
Hydrogen frequency and time standard Ch1-1007 is designed to generate and reproduce precision, highly stable, spectrally pure frequency and time signals. Main areas of application: – in metrology when transferring the sizes of units of frequency and time, including as part of mobile measuring complexes; – in radio astronomy when conducting scientific research; - in radio navigation when working as part of automated measuring systems and complexes.
-
product
Standard Flexiforce Sensors for Force Measurement
FlexiForce
FlexiForce force sensors are ultra-thin and flexible printed circuits, which can be easily integrated into force measurement applications. These sensors are available for purchase in our online store.
-
product
Standard 2.00 (57.00) - 6.00 (170.00) Non Replaceable General Purpose Probe
F-S-R
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 66Recommended Travel (mm): 1.68Overall Length (mil): 780Overall Length (mm): 19.81Rec. Mounting Hole Size (mil): 86Rec. Mounting Hole Size (mm): 2.18Recommended Drill Size: #44
-
product
15T Standard Running Line Monitor
RLM15T-3.0-S
The DLM 15T Running Line Monitor measures the tension on a rope passing through its three wheels. Typically used in cable laying and winch operations to measure and record line tension the robust design has become an industry standard. The monitor can be supplied as a separate item for integration with customers existing PLC’s or with a DLM digital display/HMI touch screen display.
-
product
Standard Slide Rail Size 3
65-051
Automatic release in extended position. The chassis/cabinet mounted slide rails are ultra rugged and hold significantly more weight and can withstand shock and vibration in harsh environments.
-
product
PXI/PXIe Microwave Transfer Switch, Dual, 40 GHz, 50 Ω, SMA-2.9, Failsafe, Remote Mount
42-782B-542-E
The 40-782B-542-E (PXI) and 42-782B-542-E (PXIe) dual failsafe transfer switches with remotely mounted relays are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 40 GHz. Connections are made via front panel mounted high quality SMA-2.9 coaxial connectors.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T30-4-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03G-003
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
product
800MM 31.5In Digital Level Bevel Gauge w/ LCD Backlight Screen, Level Bubbles IP54 Standards
DL411
Advance Plus Trading Co., Ltd.
Model Number: DL411 Key Specifications/Special Features: 800MM 31.5INCH Digital Level with level bubbles, 2 hand shanks, LCD bright backlight display, IP54 standards 1. 800mm 31.5inch level with 2 bubbles, 800*28*64mm(L*W*H), net weight: 700g;2. Resolution: 0.05°;3. Horizontal level measuring range: 0 to 360°;4. Accuracy: ±0.3°;5. Measures angle in degrees, IN/FT, mm/m, % slope or pitch;6. Audible tone at level, plump and setting angle;7. Automatic shut-off after 3 minutes;8. Backlight LCD;9. Self checking accuracy;10. Self calibration;11. Hold-function to freeze the measurement;12. Memory recall (9 measurements);13. 2pcs Handshanks design, easy to take and use;14. 2pcs high accuracy horizontal & vertical bubbles, clearly to check;15. Operated by DC 3V (2*LR03 AAA 1.5V batteries, not included); 16. IP54 waterproof & dusyproof industrial standard.
-
product
High Frequency Standard Capacitor
GenRad 1403 Series
The GenRad 1403 Standard Air Capacitors are stable, three-terminal standards in decimal values from 0.001 pF to 1000 pF. For measurement at 100 pF and below, a three terminal connection increases the accuracy by eliminating the uncertainty in the measurement introduced by the capacitances between the capacitor terminals and ground.
-
product
Standard Products
DLM’s standard product range is designed by experienced in-house design engineers and manufactured at our workshop in the UK by qualified technicians.
-
product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2A
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
Barcode Conformance Calibration Standards
Barcode symbol quality has been at the forefront of discussion among practitioners in the automatic identification and data capture (AIDC) industry since they were invented in 1951. Barcodes became commercially successful when they were used to automate checkout systems at grocery stores, with the very first scanning of the Universal Product Code (UPC) on a pack of Wrigley Company chewing gum in June 1974. The Uniform Code Council (UCC) published barcode quality guidelines, and ANSI X3.182-1990 became the first published standard for barcode quality. Since then, ISO/IEC 15416 for 1D symbols and ISO/IEC 15415 for 2D symbols have become the global standards for grading printed barcodes.
-
product
A Global Standard for Acoustic Absorption Measurements
Alpha Cabin
The Alpha Cabin has been especially designed for the measurement of acoustic absorption properties of materials and components used for the noise insulation of vehicles. The Alpha Cabin is significantly smaller than normal reverberation rooms and therefore ideally suited to use within limited space capacities. The acoustic absorption of the Alpha Cabin itself is also very low: Thanks to the high level of sound insulation, background noise in the frequency range of interest is kept to a minimum.
-
product
Standard Voltage 37 Pin D-Type Connector Blocks for Pickering
The connector blocks below are suitable to use with Pickering cards and modules that utilize a standard voltage 37-pin D-type connector.
-
product
PXI Single Microwave Transfer Switch 40GHz 50 SMA-2.9
40-782A-541
The 40-782A-541 is a single transfer switch and is part of our range of PXI microwave switching modules. It has a characteristic impedance of 50Ω and a maximum operating frequency of 40GHz. Connections are made via front panel mounted high quality SMA-2.9 coaxial connectors.
-
product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3E
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1L24-4-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25I40-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02