Product
Modbus RTU Rs486/232/422
-
It provides client/server communication between devices connected to different types of buses or networks. Modbus-RTU (Remote Terminal Unit) means that the Modbus protocol is used on top of a serial line with an RS-232, RS-485 or similar physical interface.
-
Product
Modbus Register Converter - Serial To Modbus RTU Interface
-
Translates Modbus registers and variable types from an older Modbus devices to a new Modbus device. The Model 2390 allows upgrading Modbus RTU devices without changing the system software. The 2390 also provides serial control of Modbus RTU devices for new applications that want the ease of using simple ASCII commands strings when controlling Modbus RTU devices.
-
Product
Ethernet-GPIB-USB to Modbus RTU Interface
Model 9009
-
* All interfaces provide full control of the Modbus RTU slave devices.* Ethernet port supports VXI-11, raw socket and Modbus TCP/IP to Modbus RTU conversion. * GPIB port works with any IEEE-488.2 compatible GPIB controller.* USB port uses Microsoft supplied driver to prevent operating system change problems.* The 9009 uses a simple command set that is accessible from any port.* Controllable with Windows PC programs like C, Visual Basic, LabVIEW, VEE, etc that make VISA or SICL calls. Works with Agilent, NI and Kikisui VISA libraries* Controllable from MAC/UNIX/LINUX and similar computers with RPC calls.* Ethernet interface protocol is fully VXI-11 compliant and does not require special PC drivers.* Internal webserver with sample Modbus device control pages for Watlow F4, F4T and EZ-Zone Controllers.* OEM oriented board designed for integration inside the user's system with only one cable. On board regulator works with 5 to 15 Vdc power.* Support programs Include ICS's VXI-11 and VISA keyboard control programs and a NTML page utility for uploading your customer webpages.
-
Product
Ethernet, GPIB And USB To Modbus RTU Interface Board
-
ICS's Model 9009 is a multi-interface board that allows Ethernet, GPIB or USB control of Modbus RTU devices. The Ethernet port has VXI-11 protocol for easy control by the following computer systems without special drivers: LINUX, UNIX, SunOS, MAC OS X, HP-UX, IBM-AIX and Windows 2K or later Windows systems. VXI-11 is one of the 9009's Ethernet protocols. ICS Electronics is the premier VXI-11 device supplier with 100% VXI-11 compliance in every product. See our extensive Application Notes or download our VXI-11Tutorial and the VXI-11 Specification for more information about the VXI-11 Standard.
-
Product
Ethernet To Modbus RTU Interfaces
-
ICS's Ethernet to Modbus Interfaces provide Modbus TCP/IP to Modbus RTU serial conversion and Raw Socket (Telnet) to control Modbus RTU Slave Devices. Available in small Minibox™ and OEM board formats. OEM board has Ethernet, GPIB and USB interface ports. All Interfaces include the VXI-11 protocol for use with: LINUX, UNIX, SunOS, Apple OS X, HP-UX, IBM-AIX and Windows 2K or later Windows systems.
-
Product
Modbus RTU Analog Input Modules
-
The Datexel range of Modbus RTU analog input cards for both RS485 and RS232 with Modbus or ASCII protocol can be combined with the DAT9000 series of Modbus Masters. A choice of input cards or modules are available and have various optional inputs such as Voltage, Current, Thermocouples, RTD, and Resistance. Also a choice of 2, 4, 8 channel options are available. The DAT3011 is a Modbus RTU Slave with 1 selectable universal input (Thermocouples, RTD, mV, RTD's or Resistance), 2 x 4-20mA or 0-10V input and 2 x4-20mA outputs. The DAT3011 also has 3 digital inputs and 3 relay outputs. Each module is isolated from each other and is set up using the DAT3000 software Development package which is free of charge from the Datexel download web page. Datexel also has universal input modules. An 8 channel analog input card is available making the DAT3000 series a very economical solution to large and small scale Data Acquisition. Combining these analog input cards with the analog output cards, the digital input/output cards and the communication devices make Datexel the smart choice where Data Acquisition is required.
-
Product
Ethernet to Modbus RTU Interface
Model 9099
-
* Use Modbus TCP/IP, VXI-11, or Raw Sockets (Telnet) or to control Modbus RTU slave devices.* No special driver required which eliminates driver problems.* Controllable with Windows PC programs like C, Visual Basic, LabVIEW, VEE, etc that make VISA or SICL calls.* Controllable from MAC/UNIX/LINUX and similar computers with RPC calls.* Interfaces with PLCs or any Modbus TCP/IP Controller.* Fully VXI-11 compliant.* Works with Agilent, NI and Kikisui VISA libraries.* Internal webserver with sample Modbus device control pages for Watlow F4, F4T and EZ-Zone Controllers.* Network connectivity eliminates GPIB Bus Extension problems.* Allows multiple users to access the Modbus network or devices.* 9099 is a 2x to 5x faster than the 8099 and includes a new Modbus device control page.
-
Product
Modbus-RTU I/O Modules
-
Sophisticated watchdog timer functions allow the application to define the module's failsafe output state. The watchdog timer invokes the failsafe condition when communication between the host and module exceed a duration specified by the application. For further security, a second hardware watchdog timer monitors the microcontroller for failed operations or a "lock-up" condition and automaticaly resets the unit.
-
Product
RS232 RS485 RS422 Serial To Ethernet Modbus Converters / Device Servers
-
In the past two decades, legacy serial communication protocols such as Modbus have merged rapidly with modern TCP/IP communication, yielding benefits including widely available infrastructures and greater distance, reliability, and flexibility. CommFront offers a range of industry-proven, easy-to-use serial to Ethernet converters and device servers, both hardware and software types. The applications of our serial to Ethernet converters include acting as a device server or a Modbus RTU/ASCII to Modbus TCP protocol converter; extending serial ( RS232 / RS485 / RS422 / TTL) communication distance over Ethernet network; controlling serial devices from remote Modbus TCP software or Modbus RTU master via Ethernet network; making a wide variety of M2M communication applications possible by enabling client access independent of any operating system or proprietary protocol; and converting conventional serial data network into TCP/IP network, etc.
-
Product
MODBUS RTU Test Software
-
MODBUS RTU Communication Test Program that helps users troubleshoot MODBUS RTU Communications. The software supports function codes, #3, #6 and #10(hex)
-
Product
Modbus Utility
-
A test tool of Modbus connection. Support Modbus TCP, Modbus RTU, Modbus ASCII connections. Support Modbus Functions: 01: Read coil status. 02: Read input status. 03: Read holding register. 04: Read input status. 05: Write single coil status. 06: Write single holding register.
-
Product
RS-485 Serial I/O
ADAM-4000/4100 Series
-
The ADAM-4000/ 4100 series featuring rugged industrial-grade cases are specially designed for reliable operation in harsh environments. Built-in microprocessors independently provide intelligent signal conditioning, analog I/O, digital I/O, data display, and RS-485 communication through Modbus RTU protocols.
-
Product
4 Digit Process Meter
CM1-PR
-
CM1-PR 4 Digits Process Meter has been designed in simple function and 4 digital 20.0mm LED displays with economic cost.They are can be programmed by tact switches that are hidden in backside of front bezel.They are also available option of 2 Relay outputs, 1 Analogue output or 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of industrial applications.
-
Product
Economic Type Resistance Indicator
CS1-RS
-
CS1-RS economic type Resistance Indicator has been designed with high accuracy measurement, display and communication of Ohm(2 wire) as like as Coil of motor or transformer.The meter supports Field Calibration function. It can be calibrated with sensor (Resistance) to meet machinery structure.They are also available 1 option of 1 Relay outputs, 1 Analogue output or 1 RS485 (Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of machinery and testing equipments applications.
-
Product
BACnet / Modbus
-
BACnet™ MS/TP and Modbus RTU communicating sensors provide an easy-to-install and cost-effective means to measure temperature and humidity anywhere on your network. They’re especially effective where there is limited controller inputs or the application is for monitoring only. All BACnet™ sensors are BTL Certified.
-
Product
ANSI X3.28 to Modbus RTU Converter
Model 2399
-
* Converts ANSI X3.28 commandslinto Modbus RTU packets.* New 32 Address Mode supports multi-channel Modbus Controllers like the Watlow MLS300.* Control Modbus RTU devices from any ASCII serial source.* Serial ports support RS-232 and 2-wire/4-wire RS-485 signals.* Includes serial baud rate conversion.* Internal logic is IEEE-488.2 compatible and uses SCPI commands for configurtion setup.* 2399 mounts on a DIN rail or on any flat panel.* Inexpensive way to maintain manufacturing equipment such as semiconductor fusion chambers, etc as the ANSI Controllers become obsolete.* Application Note AB23-3 describes how to use the 2399 to replace obsolete Watlow Controllers in the Axcelis/Fusion Gemini Asher.* 2399 Serial Keyboard Program lets you control and setup the 2399 and test the ANSI modes.* 239x Table Loader Program uploads ANSI Command Table entries from an Excel csv file.
-
Product
Self-reclosing Overcurrent And Residual Current Protection
-
Wide range of solutions to guarantee personnel safety as well as maximum service continuity in the event of a ground current or breaker trip, with automatic reconnection of the installation. Available with RS-485 communications (Modbus RTU) and remote control inputs/outputs.
-
Product
Modbus Register Converter
Model 2390
-
* Converts Modbus Registers and variables for replacement Modbus devices.* Maintain existing software when upgrading Modbus systems.* Provides serial control of Modbus RTU devices from any ASCII source.* User defined Register Conversion Table supports all Modbus RTU devices.* Internal Register Conversion Tables for Watlow F4-to-EZ-ZONE and F4-to-F4T conversion.* Serial ports support RS-232 and 2-wire/4-wire RS-485 signals.* Includes baud rate conversion capability.* Uses SCPI commands to load the Conversion Table and set serial settings.* Small metal case mounts on a DIN rail or on any flat panel.* 239x Table Loader Program uploads the 2390 Register Conversion Table from an Excel csv file.* 239x Serial Keyboard Program provides instant control of the 2390 and Modbus Slave Devices without writing a program.
-
Product
4 2/3 Digit Voltage/Current Meter
CS1-VA
-
CS1-VA economic type Voltage/Current Meter is designed with high accuracy measurement, display and communication of 0~600V or 0~10A for DC/AC/TMRS.They are also available 1 option of 1 Relay outputs, 1 Analogue output or 1 RS485 (Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of industrial and testing applications.
-
Product
Modbus/TCP Gateway
MODG-100
-
MODG-100 is a Modbus/TCP to Modbus RTU gateway. Itfeatures one serial port which can be configured as either RS-232, RS-485 or RS-422 and an Ethernet port. It can be mounted on a DIN rail.
-
Product
4 Digit Temperature Meter (5 Channels)
CM1-TX5
-
RS-485 Modbus RTU protocol (with communication LED indicator)RS-485 address 1~255Communication Baudrate 9600, 19200, 38400, 57600, 115.2KParity check N81, N82, E81, O81Input 5 channels of signal selectable:thermocouple/PT100.5 channels of input can be set to play 1~10 seconds loop display.1~5 channels of display value limits can be set, and the number of channels of carousel display screens can be set by yourself.5 channels of input signals with LED unit cycle display.Standard 2 groups of alarms Hi, LO with communication LED indicators to ensure the normal operation of the field system.Suitable for HVAC refrigeration and air conditioning PLC, DDC, PC brands to achieve remote real-time monitoringCan be used in solar panels, medical control, clean room, ice water host, boiler, motor, chemical plant, power plant, school energy-saving control, remote control of power monitoring panel
-
Product
5 Digit Frequency Meter
CS1-F
-
CS1-F economic type Frequency Meter is designed with high accuracy measurement, display and communication of Frequency.The innovation feature is auto-range input from 0.01Hz~100KHz(option ~140KHz) and the display resolution will auto-change to show the highest according to input frequency.They are also available 1 option of 1 Relay outputs, 1 Analogue output or 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of panels and testing applications.
-
Product
Analog I/O Modules
-
Remote RS-485 I/O modules using Modbus RTU protocol offer complete analog I/O for current, voltage, thermocouple or RTD.
-
Product
4 2/3 Digital Temperature (RTD) Meter
CS2-T
-
CS2-T Temperature Indicator has been designed with high accuracy measurement, display and communication of Thermocouple or Pt100Ω.They are also building in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS485 (Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of machinery and testing equipments application.
-
Product
Digital Panel Meter
CM3-VA7
-
CM3-VA7 is a multifunctional 3-phase voltage/ current meter.With 3 phase voltage or current display at the same, configurable display range via front buttons, anti-inference design, reliable quality and easy to use and install CM3-VA7 also has multiple I/O functions including 3 relay outputs, an analogue output and a RS485 communication port running the Modbus RTU Protocol.
-
Product
Networked Absolute Inclinometer
T7
-
The T7 is available in several interface and protocol options. The physical interface can be RS232, RS485 or US Digital's CAN (Controller Area Network). The protocol can be either US Digital's serial protocol or Modbus RTU. The RS232 version supports a single T7 with up to 100 ft of cable. For users that need longer cable lengths or multiple T7s on a single bus, the RS485 or US Digital CAN (Controller Area Network) version can be used. The USD-CAN protocol allows a network of up to sixty-four T7s to be connected to a single host. Power for each T7 is supplied over the CAN network cable. The host accesses the USD-CAN T7s through US Digital's low cost CANA-232/CANA-485 adapter module. This module allows the host to access each T7 on the network using simple, easy serial port commands, just like the RS232 version. The RS485 version supports up to 32 T7s on the bus.
-
Product
Process Indicator
CS1-PR
-
CS1-PR economic type Process Indicator has been designed with high accuracy measurement, display and communication of DC signal 0~10V and 4(0)~20mA.They are also available 1 option of 1 Relay outputs, 1 Analogue output or 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of industrial applications.
-
Product
Modbus Stack
softMOD
-
SoftMOD is the industry-standard Modbus protocol stack for industrial automation and building management. SoftMOD supports both Modbus RTU (Remote Terminal unit) and Modbus TCP/IP (Transmission Control Protocol) as well both client and server modes.
-
Product
RPM Indicator
CS2-RL
-
CS2-RL RPM Indicator has been designed with high accuracy measurement, display and communication of pulse (Frequency).The innovation feature is auto-range input from 0.01Hz~ 100KHz (option ~140KHz) and the display resolution will auto-change to show the highest according to input frequency.They are also building in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of testing and machinery control applications.
-
Product
Ethernet To Modbus RTU Minibox™ Interface
-
ICS's Model 9099 Ethernet to Modbus RTU Interface is a small Minibox™ Ethernet Modbus Converter that converts Modbus TCP/IP, VXI-11 and Raw Socket to control Modbus RTU Slave Devices. The Model 9099 does not require special drivers and is compatible with the following systems: LINUX, UNIX, SunOS, MAC OS X, HP-UX, IBM-AIX, Windows 2K or later and Modbus capable PLCs. ICS's 9099 uses VXI-11 RPC calls for secure communication with virtually any computer. Easily programmed on a PC by making VISA calls or on a MAC/UNIX/LINUX computer with RPC calls. Special drivers are not required. ICS Electronics is the premier VXI-11 device supplier with 100% VXI-11 compliance in every product. See our extensive Application Notes or download our VXI-11 Tutorial and the VXI-11 Specification for more information about the VXI-11 Standard.