Jitter
Unwanted signal deviation.
-
Product
Contrast Sensors
-
Leuze electronic GmbH + Co. KG
Contrast sensors detect and compare contrasts very precisely through the use of different light sources such as white light, laser-generated red light or RGB light. The detected contrasts marks are then reported to the process with minimal signal jitter. Through the automatic selection of the right transmitter colors, various color or gray value combinations can be reliably detected. Bar graph indicators offer additional ease in making adjustments during manual setup.
-
Product
Mixed Signal Oscilloscope: 13 GHz, 4 Analog Plus 16 Digital Channels
MSOV134A
Oscilloscope
13 GHz analog bandwidth (upgradable)4 analog plus 16 digital channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.09 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Access the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
Product
PXI/PXIe
-
Four independent delay channels 1 ps resolution < 50 ps rms jitter >20 second delay range Four auxiliary delay channels 5 ns resolution < 100 ps rms jitter >20 second delay range Front panel or PXI bus PXI 3U, 1 slot, compact packaging更多其他产品内容可咨询:400-621-8906
-
Product
Infiniium V-Series Oscilloscope: 13 GHz, 4 Analog Channels
DSAV134A
Oscilloscope
13 GHz analog bandwidth (upgradable)4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.09 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
Product
Infiniium V-Series Oscilloscope: 33 GHz, 4 Analog Channels
DSAV334A
Oscilloscope
33 GHz analog bandwidth4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (2.09 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
Product
Resonant Choppers
-
Electro-Optical Products Corp.
Resonant optical modulators (choppers) modulate light beams at their fixed, resonant frequency. Resonant choppers require low power and are not susceptible to blade phase jitter or motor speed jitter. A wide selection of vanes, mirrors, prisms, lenses, gratings, and other components can be attached for endless possibilities in light modulation.
-
Product
Digital Multiplexers
-
Advanced Science and Novel Technology, Co., Inc.
High speed broadband 4:1 Multiplexer (MUX)Exhibits low jitter and limited temperature variation over industrial temperature rangeDifferential CML I/O data and clock buffersQuarter-rate clock outputSingle +3.3V or -3.3V power supplyPower consumption: 960mWFabricated in SiGe for high performance, yield, and reliabilityCustom CQFP 44 pin package
-
Product
Enhanced Time-Domain Analysis With TDR
S95011B
-
This application enables the analyzer to perform enhanced time domain analysis for high-speed data applications. All functionality of the S95010B are included (TDR/TDT mode). In addition, the S95011B enables more detailed measurements and evaluations, such as eye-diagram / mask modes, without adding PLTS software. Jitter and emphasis / equalization capabilities enable simulation of real-world signals and environment. The S95011B covers up to 53 GHz bandwidth. Full calibration is available and the automatic deskew ensures easy removal of fixture and probe effects. To get the best accuracy, mechanical calibration kits or ECal with DC option (i.e., N469xD or N4433D with Option 0DC) are recommended.
-
Product
MPI PCB Probe Systems
-
MPI Advanced Semiconductor Test
Every MPI manual probe systems can be configured with a variety of different holders for printed circuit boards (PCB’s) in order to provide in addition to on-wafer, versatile, convenient, and accurate Signal Integrity (SI) measurements with single-ended or differential RF probes. Measuring signals at the end of the channel for eye-patterns, deterministic jitter, distortion, TDR (Time Domain Reflectometry) impedance, cross-talk, coupling, and losses, or even S-parameters is easily accomplished.
-
Product
Enhanced Time Domain Analysis With TDR
S96011B
-
Use S96011B to perform enhanced time domain analysis for high-speed data applications. Includes all functionality of the S96010B (TDR/TDT mode). In addition, the S96011B enables more detailed measurements and evaluations, such as eye diagram / mask modes, without adding PLTS software. Jitter and emphasis / equalization capabilities enable simulation of real-world signals and environment. The S96011B covers up to 53 GHz bandwidth. Full calibration is available and the automatic deskew ensures easy removal of fixture and probe effects. To get the best accuracy, use mechanical calibration kits or ECal with DC option (i.e. N469xD or N4433D with Option 0DC).
-
Product
Mixed Signal Oscilloscope: 25 GHz, 4 Analog Plus 16 Digital Channels
MSOV254A
Oscilloscope
25 GHz analog bandwidth (upgradable)4 analog plus 16 digital channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.73 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Access the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
Product
1pps-Locking-Modules
-
This is a module to control an OCXO or Rubidium oscillator with 1PPS from a GPS receiver. The Quartzlock A6-1PPS uses a 3 state Kalman filter algorithm to measure & correct the frequency offset of the oscillator with respect to the 1PPS input. Time-tagged input 1PPS to 200ps resolution & <1ns jitter. Analog interpolator is self calibrating. Interface to GPS decodes messages & extracts relevant info. i.e. time correction data for 1PPS output, this has AVAR of the Rb or OCXO i.e. 5 x 10-12/s & <100ps RMS jitter. The output is steered to time coincidence with GPS time/UTC to 1ns resolution. Holdover initiated by 1PPS fail or data from GPS RX that 1PPS is inaccurate. During holdover, measured frequency offset & drift steer the oscillator & 1PPS is still available.
-
Product
Computer-Based Instruments
GT210PCI
-
with the GT210PCI you can determine any frequency to 0.01 part per million (eight digits) in just 1 mS, and resolve each time measurement to 8pS. Couple that with 2300 measurements per second, one of the fastest rates available and you can acquire more data in a single second than a typical GPIB counter can in one minute! Faster measurements and higher resolution, along with built-in statistics functions give you a more thorough analysis of your signal. Standard deviation, peak to peak jitter, or a graph of the measurements are available at the push of a button.
-
Product
D-Type Flip-Flops
-
Advanced Science and Novel Technology, Co., Inc.
High speed broadband D-Type Flip-Flop for data retiming with full rate clockExhibits low jitter and limited temperature variation over industrial temperature range6.5ps set-up/hold time capability87% clock phase margin for retiming of data input eyeFully differential CML input interfacesFully differential CML output interface with 400mV single-ended swingSingle +3.3V or -3.3V power supplyPower consumption: 415mWFabricated in SiGe for high performance, yield, and reliabilityCustom CQFP 24-pin package
-
Product
Infiniium V-Series Oscilloscope: 25 GHz, 4 Analog Channels
DSAV254A
Oscilloscope
25 GHz analog bandwidth (upgradable)4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.73 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
Product
Function/Arbitrary Waveform Generators
SDG5000 Series
-
Siglent Technologies invented the pulse generator algorithm EasyPulse, which is found in the SDG5000 waveform generators. Based on this new technology, the SDG5000 is capable of generating a pulse signal with low jitter, fast rising and falling edge (frequency independent effect), small duty cycle, edge and pulse width can be a wide range of adjustment.















