Ground Fault Locators
find an electrical cable's current leakage or fault.
-
product
Service Ground Test Set
900
TESCO’s Service Ground Test Set has been designed to check the condition of the ground connection on a secondary service. If for any reason the ground connection has a resistance, this can be immediately detected by the Test Set. The Service Ground Test Set consists of a voltmeter which can be shunted by a resistance of 60 ohms. The voltmeter is of the suppressed zero type with a double range, from 65 to 130 or from 130 to 260, and can be used for checking service voltage independently of the ground test.
-
product
Universal Ground Control Station
UGCS
UGCS is the common control station for the U.S. Army's Shadow®, Hunter and Gray Eagle™ unmanned aircraft systems. Built on a flexible crew station architecture, the UGCS can be configured and housed based on customer requirements, supporting a wide variety of assets and operations.
-
product
Ground Penetrating Radar Utility Locator
PinPointR
The ImpulseRadar PinPointR offers a clear and dependable way to quickly and easily locate, avoid or map underground utilities with the functionality required to meet approved industry standards, whilst offering market-leading performance and data quality.The enhanced bandwidth of the PinPointR antenna provides resolution beyond that of any single-channel GPR system for the detection of near-surface utility targets and other internal reflectors of interest, as well as deeper utility targets with maximum depth penetration.Key features:- RTS-based Antenna technology- Dual-channel operation- Android-driven interface- Wireless data acquisition- Integrated GPS, with external GPS support- No survey speed limitation
-
product
Cable and Pipe Locating Equipment
The most advanced locating kit combining the functions of three devices: cable locator, water leak detector, non-metal pipe locator.
-
product
PXI Dual Bus 32-Chan 2A Fault Insert Switch
40-190B-202
The Dual Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
Ground Network Earth Resistance Tester
HTDW-5A / 736
Wuhan Huatian Electric Power Automation Co., Ltd.
It is suitable for the test of grounding resistance of large power grid in power departments, substations and other institutions.
-
product
Portable Static Grounding Kit
Grounding Kit
The portable grounding kit combines multiple shortened grounding rods with surface wire grounding techniques to provide acceptably low resistance for static grounding requirements in field operations.
-
product
PXI Dual Bus 32-Chan 2A Fault Insert Switch, N/O Through Relays
40-190B-502
The Dual Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.
-
product
Fault Injection and White-Box Testing
VectorCAST/Probe
VectorCAST/Probe is integrated with the full family of VectorCAST tools allowing probes to be inserted during Unit, Integration, or System Testing. The probe insertions are controlled by the same technology that controls our code coverage instrumentation, which ensures that the probes function correctly regardless of the compiler, target processor, or run-time environment.
-
product
Ground Threat Emitter Sensor System
GTESS
The Ground Threat Emitter Sensor System (GTESS) is a modular test and training system capable of stimulating multi-spectral aircraft electro-optic sensor suites at long range. The GTESS system integrates Textron Systems’ ultraviolet (Mallina™), infrared (Phoenix) and/or laser (Phantom™) ranged stimulators with an automated tracking system to facilitate fast-moving test, training and evaluation exercises. A fully integrated camera system for effective after action review. GTESS can also work in conjunction with Textron’s radio frequency (RF) range stimulator systems (PRTS™ & HPRTS) for complete multi-spectral testing.
-
product
Visual Fault Locator VFL
X4007
X-4007 series visual fault locator is used for the measurement in single-mode or multi-mode fibers. It features a rugged design, a universal connector and an accurate measurement.
-
product
DC Ground Fault Finder
FST-JD200
Foresight Electronics Co., Ltd.
FST-JD200 not only can provide a solution on accurately testing the faults of the indirect-grounding of the direct current system, non-metal grounding, loop grounding, simultaneous grounding of the anode and cathode, balanced grounding of the anode and cathode and multi-point grounding 1.
-
product
Automated Digital Ground Continuity Tester
Educated Design & Development, Inc.
1 Button Testing - No setup required, just plug right in!Digital LED display reads out in OhmsAlso performs the Low Current Ground Continuity test, at the same time!Auto Test Time (1 sec. / 60 sec.)+ - No need to set a timer or clock watchCustom universal receptacle accepts both 120V and 240V plugs.Zero feature allows you to "zero-out" the test lead impedance.Meets UL, CSA, CE, EN, IEC, MIL and all other international safety agency requirements.
-
product
Ground Resistance
Provide accurate and reliable measurements of both ground resistance and soil resistivity for installation and troubleshooting.
-
product
GPR Utility Locating Tools
LMX100™
LMX100™ offers the perfect balance of depth penetration and resolution for accurate locating. Data is collected in Locate & Mark mode; this provides a real-time image in the field to identify utilities and mark their locations.
-
product
Generator Neutral Grounding & Leads Cubicles
Generator Neutral Grounding Cubicles are designed to minimize fault damage incurred by generators, maintain sufficient fault detection and improve power system reliability. Generator Neutral Grounding and Lead Cubicles are manufactured as for IEEE or IEC standards.
-
product
Underground Fault Location
Schweitzer Engineering Laboratories, Inc.
Underground faulted circuit indicators identify the faulted cable section without a time-consuming re-fuse and sectionalize process. Applications include subsurface or pad-mounted transformers, switchgear, sectionalizing cabinets, junction boxes, and splices.
-
product
Cable and Pipe Locator
PT-14
The locator PT-14 is used as an induction signal receiver in a cable tracing and fault location set for the following applications:• tracing – finding the route and determining the burial depth of underground cables and other hidden utilities;• fault location – pinpointing interphase and phase-to-sheath short circuits faults;• cable identification – identifying a correct cable from a bunch.
-
product
Acoustic Fault Detector
AFL212-AMD
K&S Engineering and Scientific Ltd
This compact acoustic headset, designed and manufactured by K&S Engineering and Scientific Ltd has been developed with state-of-the-art components to not only to achieve superior performance but also to offer the user an acoustic headset that is smaller than equivalent units currently available on the market. Housed in an IP67 enclosure, the unit, which is used in conjunction with a high voltage surge generator, can easily contend with wet conditions.
-
product
PXI 34-Channel 4-Bus 2A Fault Insertion Switch
40-197A-001
This 34-channel fault insertion switch is primarily intended for routing simulated fault conditions in automotive and aerospace applications involving the reliability testing of safety critical controllers. A low cost 16-channel option is also available.
-
product
Static Grounding Protection for Tank Trucks
Earth-Rite RTR
Precision and reliability is what the Earth-Rite RTR provides to HAZLOC safety professionals and engineers who are tasked with protecting personnel and plant assets from the ignition hazards of static electricity during tank truck loading and unloading operations.
-
product
Hazardous Location Syringe Pump
500HLf
The Teledyne LABS HLf-Series pumps give you the same accurate, predictable flow and pressure control as our standard D-Series, while conforming to safety standards for use in UL Class I, Division 2, Groups A B C & D, T4 environments. The hazardous location rating is achieved through internal design modifications including the use of brushless DC motors. This approach eliminates the need for purge boxes or other additional safety devices. Wetted materials are compatible with most aqueous and organic liquids, corrosive solutions, heated fluids, liquefied gases, viscous fluids, or slurries and pastes. If needed, optional materials such as Hastelloy C-276 are available on request. The HLf controller has a keypad and LCD, as well as built-in and optional interfaces for computer control and other devices. Programming is easy and flexible, with instant access to menu screens even when the pump is running. This allows you to change operating parameters on the fly.
-
product
Multi-layer Short Circuit Locator
Toneohm 950
Polar Toneohms are ideal tools for the electronics production environment. Able to locate shorts quickly and accurately on both bare and loaded PCBs, they provide a very cost-effective means of minimizing repair and rework of faulty PCBs that have been identified by pass/fail testing on an ATE system.
-
product
Ground Resistance Tester
Weshine Electric Manufacturing Co., Ltd
1.Soil resistivity tester supports 2, 3 and 4wire grounding resistance measurement. 2. 4digit large LCD display with white screen backlight, suitable for use in dimly lit places. 3. IP65 protection grade, good waterproof, compact and portable, supports multiple functional tests.
-
product
High Resistance Neutral Grounding Devices
HRG systems limit the fault current by placing high resistance between neutral point of transformer (or generator) and ground. As it is not possible to locate the fault point in delta connected systems, an artificial neutral point is created and delta connected system can be grounded. This allows a fault current of a few amperes thus locating the fault point gets easy. When the neutral point is grounded thru high resistance, both continuity of operation is provided during fault condition and sufficient current (typically between 2 A and 10 A) flow is provided for ease of locating the fault point.
-
product
Cable Fault Finder
Techno Instrumentation (India) Private Limited
Magnetic and Acoustic signal strength through bar graph and digits on LCD.Coincidence feature gives distance to the fault in milliseconds.Easy, fast and accurate pinpointing of faults.