Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
Standard Voltage 9 Pin D-Type Connectors for Pickering
The connectors below are suitable to use with Pickering cards and modules that utilize a standard voltage 9-pin D-type connector.
-
product
Galvanostat and Zero Resistance Ammeter
This instrument offers a Potentiostat, Galvanostat and Zero Resistance Ammeter with integrated Frequency Response Analyser and Sweep Generator in one. It is based around a two Amp Potentiostat teamed with a two Amp Zero Resistance Ammeter and can be supplied as - 6 channel, with six sequential channels, 8 channel (eight sequential channels) or 12 channel (twelve sequential channels). Connection to the controlling Windows PC is via a standard RS232 port, optically isolated for full floating operation. The instrument is supplied with a full set of cables and software, user manual and application notes on CD.
-
product
Butt Set
MT-8001
Recognized as the new industry standard, the MT-8001 butt set provides superior quality at an affordable price. With its high impedance monitor for data safe operation, technicians can clip onto a line in Monitor mode without disrupting existing traffic. Prokit's unsurpassed protection standards and durability assure the butt set will keep working even in the toughest environments. New weatherproofing provides enhanced resistance to severe weather conditions.Features
-
product
Solar Analyzers
Max. solar system power (Pmax) search by Auto-scan: 1000V, 12A (12000W capability)The analyzer and the Remote Solar Detector is connected by Bluetooth wireless communication (Bluetooth 2.1 + EDR Class 1)The Remote Solar Detector is moisture-proofIntelligent test logic with no personnel attendance required in the field Solar system analyzer waits and tests the system until appropriate sunlight irradiance is detectedMax. voltage (Vpm) at Pmax, Max. current (Ipm) at Pmax Voltage at open circuit (Voc), Current at short circuit (Isc)Efficiency (%) calculation of solar systemTemperature measurement of solar panelsIrradiance measurement of sun lightSeries resistance (Rs) calculation of solar panelsWith data logging/open function, the I-V curves of solar system can be analysed / recorded for a period of time (e.g. 60 min.)Conversion of I-V curve under OPC to data under standard test condition (STC) based upon IEC standardProvide Operating Condition (OPC) and Standard Test Condition (STC) test reports for verification of solar panel performance (OK or NO OK)Users can set up the parameters of solar panelsUsers can set up the series number of solar panels. Parameters of many solar panels can be measured in one measurementThe Irradiances and Temperatures of solar panels can be continuously measured, monitored and recordedContinuously measure/monitor/record the DC power output of solar system and the AC power output of inverter (1 phase or balanced 3 phases)Calculate the efficiency of DC to AC power conversion and the efficiency of the max.output power
-
product
Standard 1.08 (31.00) - 4.00 (114.00) Long Travel Bead Probe
BPLT-25HL-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
product
Surface Resistance Meter Kit - Test Anti-Static, Static Dissipative and Conductive Surfaces
PRS-812RM
- Surface Resistance Tester from 0.10 Ω to 1 Teraohm- Constant Voltages 10 volts and 100 volts- Automatic Electrification Period- Determines if a surface is Dissipative, Conductive, or Insulative- Measures resistance point-to-point(Rtt) and resistance to ground (Rtg)- Measures resistance of ESD Flooring, ESD Worksurfaces and Packaging- Conforms to all ESD Association Standards for Resistive Characterization- Includes 2 each Surface Resistance Probes- Packaged in a hard shell Carrying Case- Certificate of Calibration Traceable to NIST included- 2-year Limited Warranty on Main Instrument
-
product
Comparative Tracking Index Apparatus
CTI-01
Is designed to perform the test specified in many standards where resistance to Tracking in insulating partssupporting live parts is required to be established.
-
product
Ultra High 1.16 (33.00) - 9.70 (275.00) Long Travel Bead Probe
BPLT-25HF-9.7
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
product
Low-Temperature Impact Device
DWC-1
This low-temperature impact device is compliance with standard requirement of IEC60245, IEC60227, IEC60540, GB5013-2008, GB5023-2008 and GBT2951-2008. It’s used to test all kinds of PVC sheathed cable, wire, soft wire and no sheath of parallel soft PVC insulated impact resistance at low temperature. Specification: • Working temperature: -15℃±1℃ • Impact height: 10~200mm adjustable • Length of specimen: 5D~150D • Material: 304 stainless steel • Completion time once: 3~5s • Completion number of units for once: ≥2pcs • Weight: 100/200/300/400/500/600/750/1000/1250/1500g • Low temperature box to match additionally
-
product
MultiMeter 1000V TRMS
CZ20062
This multimeter is a rugged, weatherproof, digital multimeter (DMM) designed specifically for electricians and electrical contractors. Fully featured and well priced, this DMM should be in everyone's toolbox. Voltage, current, resistance, capacitance, and frequency are all included as standard.
-
product
Ball Pressure Test Apparatus
The Ball Pressure Apparatus is designed to perform test specified in IS Standard where resistance of insulating material to elevated operating temperature is to be determined. It is used to test insulation materials used in Electrical Appliances, Electrical wiring accessories, luminaries, motors, connectors, etc. It is a precision engineered test instrument for use by safety and compliance testing laboratories.
-
product
SIL Reed Relays
Series 105
• SoftCenter™ construction• Highest quality instrumentation grade switches• Encapsulated in a plastic package with internal mu-metal magnetic screen• Wide range of switch confi gurations -Form A, 1 Form B, 2 Form A, 1 Form C• Two pole relay requires the same board area as the single pole type• Dry and mercury wetted switches are available with the same pin configuration and footprint.• Many benefits compared to industry standard relays. Learn more here >.• Insulation resistance greater than 10E12 Ohms (1TOhms) for dry Form A devices• 5, 12 and 24 Volt coils are standard, with or without internal diode• 100% tested for dynamic contact resistance
-
product
MEGMET 501 D
PU 182.1
The instrument is primarily intended for measurement of the insulation resistance of electrical objects and equipment according to the CSN 331610 standard (for electrical appliances) with nominal voltage 100 V, 250 V and 500 V. It also allows to measure AC and DC voltage up to 550 V,
-
product
Cable Testing Service
Cable testing service available from Cimbian includes:Helping you with the test specificationBuilding the test interface, where necessaryCreating the test programBarcodingTest reportsSimple continuity testingMeasurement/verification of resistances and diodes (traceable to national standards)Hi-Pot testing to 1500VDC / 1000VAC
-
product
Digital Multimeter
DMM
Is a test tool used to measure two or more electrical values—principally voltage (volts), current (amps) and resistance (ohms). It is a standard diagnostic tool for technicians in the electrical/electronic industries.
-
product
STDETransformer Demagnetizer
STDE
This option allows neutralizing the residual magnetization of the power transformer core after the winding resistance test. The principle of the option is to apply a constant current of alternate polarities to the transformer winding, as per the IEEE 0062 1995 standard.
-
product
Automated Resistance Standard
SmartResistor
The SmartResistor combines, into one transportable device, all the items needed to maintain resistance: a set of standard resistors, a controlled temperature bath, a low thermal emf scanner, and measurement data.
-
product
Transformer ON-Load Tap-Changer Tester
WAYZ-2011
Wuhan Sangao Electrical Test Installations Limit Co.
This Transformer on-Load Tap-Changer Tester is acc to Chinese Electric Power Industry Standard, It also can meet the requirement of electrical equipment handover and prevention test standard.To achieve the accurate measurement of on load tap changer's transition time, transition resistance,three-phase synchro nization parameterssyn.It is the best test equipment of on-Load Tap-Changer.
-
product
Standard 1.08 (31.00) - 4.00 (114.00) Long Travel Bead Probe
BPLT-25HF-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
product
High Impedance Active Probes
7A
An unterminated version, can be used for capacitance and resistance measurements or in low to medium speed signal applications where a 50 ohm termination is not required. A flexible coaxial cable length of 6 feet in length is standard on the Model 7A; however, when used for capacitance measurements, GGB Industries, Inc., recommends using a shorter 3 foot cable. If a shorter length of cable is desired for capacitance measurements, please specify it when ordering (Model 7A-3ft.). Please note that Model 7A uses Model 7 replacement tips.
-
product
DC Resistance and Current Measurement System
DC Resistance and Current Measurement System including: 6622A Series Bridge, 6634A Temperature Stabilized Resistance Standards, 6664C Scanner(s), world’s most precise and stable 6623A Precision Current Source/Range Extender, Wired Equipment Rack, and Bridgeworks Software.
-
product
Glow Wire Test Apparatus
GWT A2
GLOW WIRE TESTER (also known as Glow Wire Test Apparatus) is designed to carry out fire hazard testing as specified in IEC 60695-2-10 2000-10. Flammability test is to check the ‘Resistance to Fire’ of electrical insulators that touch directly conducting parts & also parts of insulators. This test is also referred in many other standards such as IS 11000, IS 3854 : 1997 / IS 1293 :1988 / IS 371 :1999 & IS 11000 Pt 2 Sec 1, IEC 60335, IEC 884/94, IEC 60598, IEC 61058, BS 6458, BS EN 60695–2-10,11,12, etc.
-
product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP026-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
Transformer Winding Resistance Meters
TWA Standard Series
The TWA standard series instruments are designed to measure the resistance of six coils and simultaneously analyze the three-phase tap changer on load of the primary and secondary transformer coils (provided by model TWA40). This is done in a single cable configuration, with test currents up to 40A. Each transformer configuration has a special measurement algorithm that is optimized for rapid stabilization of test results. The TWA instruments generate a true DC current without ripple. Both current injection and magnetic circuit energy discharge are automatically regulated.
-
product
Digital H.V. Insulation Tester(15kV)
7016 IN
Standard Electric Works Co., Ltd
● Protection class: IP66 (Lid closed)● Test insulation resistance up to 30TΩ (30000GΩ).● Short-circuit current up to 5mA● Microprocessor controlled.● 30 insulation test voltages : 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 12.5kV, 13kV, 13.5kV, 14kV, 14.5kV, 15kV● AC/DC voltmeter (600V).● PI (Polarization Index) indication.● DAR (Dielectric Absorption ratio) indication.● Auto-ranging on all insulation ranges.● Backlight function.● Menu driven.● Visual and audible warning if external voltage is present. (≥30Vac or ≥30Vdc)● Auto-hold function to freeze the reading.● Overload protection.● Adjustment for testing time (duration) : 1~30 minutes● Auto-off.● Calendar.● Optical USB to RS-232 data transmission.● 200 measurement results can be saved in the memory and recalled on the display.● Safety standard : EN 61010-1 CAT IV 600V EN 61010-2-030 EN 61326-1
-
product
Resistance Meter - Portable, Precision Resistance Measurement from 0.10 to 1.00 x 10^12 Ohms
PRS-812B
- Wide Range Resistance: 0.10 Ω to 1.00x1012 Ω- Accuracy of ±2% from 1.00 Ω to 9.99x1010Ω- Constant Test voltages 10V and 100V for specification measurements to meet international and domestic ESD measurement standards- Auto Resistance Range Control- Auto Test Voltage Control- Uses a Rechargeable Li-ion Battery Pack- Takes Approximately 8,000 Measurements on a Single Charge (480 hours typical)- 120 Data Set Internal Memory- Uses Standard USB Cable for Charging- Charges in 2 Hours- 2-year Limited Warranty on Main Instrument
-
product
Precision Resistance Meter
IC4
Precision digital resistance meter IS4 is intended for use in an upgraded version of the TEST-9110 installation quality control system and testing on-board cable networks. The IC4 module can also be successfully used in other control and measurement systems based on the open international VXI standard.
-
product
3 Wire (Analogue) Earth Resistance Tester
4105 ER
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories.● Battery operated.● Battery life indicator. ● Calibration performed with supplied test leads.
-
product
Palm Size Digital Multimeter, Calibrated, 1999 Count, Mean Value, Manual Range, 3.5 Digit
72-7770 CAL D
The 72-7770 CAL D from Tenma is a palm sized digital multimeter with 3 3/4 digit LCD. It is 3 1/2digits with steady operations, fashionable design and highly reliable hand held measuring instrument. The meter measures AC/DC voltage, AC/DC current, resistance, temperature, diode and continuity. It is an ideal tool for maintenance. The multimeter features square wave output, data hold, low battery indicator and display backlight, This meter complies with the standards CE, IEC61010, in pollution degree 2, overvoltage category (CAT I 600V, CAT II 300V) and double insulation.
-
product
Oil Immersed Transfer Standard
esi SR1030 Series
The esi SR1030 transfer standards consist of 12 equal steps. These steps are available in increments of 1 (SR1030-1), 10 (SR1030-10), 100 (SR1030-100), 1k (SR1030-1k), 10k (SR1030-10k) and 100k (SR1030-100k). The esi SR1030 provides four-terminal connections for each step or for series and parallel combinations of these resistance steps using the optional Series-Parallel (SPC102), Parallel Compensation Networks (PC101) and shorting bars (SB103). This improves power dissipation, stability and errors due to variance in temperature. The esi SR1010 and esi SR1030 are used for the same applications and are alike in configuration. The esi SR1030 differs from the esi SR1010 in that it is specially sealed, and values below 100 k are filled with oil to improve changes due to thermal variations.
-
product
Insulation Meters
Here you will find an insulation tester for a variety of ranges between 50 mega ohms and 2000 mega ohms. The portable manual insulation tester is used for determining insulation resistance, continuous current, alternating current and testing. With an insulation tester, measurements can be taken for different voltages, beginning with 100V up to 10,000V. Measurements meet the DIN VDE 0413 part 1 standard. The insulation tester comes with a test mechanism, clips, batteries and a carrying case. The insulation meter can be equipped for test laboratories if an optional DIN EN ISO is acquired.Measurement of insulation in cables and motor coils is vitally important for the prevention of accidents and damage to installations and is obligatory according to most codes of conduct.