Filter Results By:
Products
Applications
Manufacturers
Load Banks
Test a power source by providing controlled amounts of load to create conditions found in thier application.
See Also: AC Load Banks, DC Load Banks, Inductive Load Banks, Reactive Load Banks, Resistive Load Banks
- Pickering Interfaces Inc.
product
PXI 2 Amp Multiplexer, 8-Bank, 8-Channel 2-Pole
40-659A-102
Model 40-659A is an 8 Bank 8 Channel Multiplexer module with 2-pole switching, It uses high quality electromechanical relays and is suitable for switching signals up to 2Amp, 300VDC/250VAC. The 40-659 module is suitable for multiplexer applications where two signals are required to be switched simultaneously, for example send and return signals in a telecoms system. It is also suitable for applications where reed relay based multiplexers do not have sufficient power handling capability such as switching medium power AC or DC loads or for slaving external relays, contactors and solenoids.
-
product
Outdoor Permanent Mounted Load Bank
Mosebach Manufacturing Company
Mosebach Pad Mounted Load bank is designed to be permanently mounted next to a generator for dedicated testing. Its unique design allows it to be one of the smallest on the market! This size enclosure will fit 50 kW, 75 kW or 100kW of testing ability. Also available in 300kW and larger load banks.
-
product
Rack Mounted Load Banks
Traditional commissioning is a daunting task. Since formal system operation doesn’t begin until the system is commissioned, the commissioning team experiences intense pressure to complete the commissioning process quickly. Commissioning can involve high expense and requires staffs from different departmental disciplines to work together. For these reasons data center commissioning has almost uniquely been associated with large data centers (over 20,000 ft2 or 1,858 m2). In the recent past, many data center managers chose to roll the dice and perform little or no commissioning, relying only on start-up data to press ahead with launching the new data center. Given the reality of 24x7 operations, however, the alternative of exposure to major system failures and accompanying downtime is no longer an economically viable option. Commissioning has now become a business necessity. JUNXY series AC & DC rack mounted load banks can be used to introduce heat loads and to allow for simultaneous testing of both electrical and cooling systems.
-
product
Battery Loading Unit
BLUe
BLUe series Battery Loading Units; portable instruments for controlled & monitored discharge of batteries. It is designed for integrated site discharge test, design & QC test and also for monitoring discharge process of battery bank with connected load. Single autonomous unit having inbuilt display, keypad and wireless communication with PC makes it very easy to use. It comes in different configurations ranging from 12V to 380V discharge voltages and 50A to 300A discharge currents. Various options are available to control & monitor the discharge process. With the help of optional Cell Monitoring Unit - CELLMon, voltage of each individual cell can be monitored & data sent to main BLUe unit and then from main unit to PC via wireless communication. Each BLUe unit is supplied with PC downloading & analysis software for real time monitoring of discharge process.
-
product
Battery Load Bank
K-3980
Kongter Test & Measurement Co., Limited
Kongter offers a series of customized DC load banks with many different models for constant current battery discharge test and battery capacity test. They cover a wide voltage range from 12V to 480V nominal voltages with current up to 600A. They are widely applied in various industries. With its optional battery Data Acquisition Case (DAC), discharge values of EACH cell could be monitored in battery load bank and PC software simultaneously by using Kongter’s data view software.
-
product
Dc Load Bank
Highly reliable and durable new alloy resistor is used for the JUNXY DC load bank. It is thermal shrinkable and seal installed in the stainless steel pipe, whose surface with insulated heat sink. The resistor is moisture-proof, anti-corrosion, good heat dissipation, high insulation resistance, safe and reliable.
-
product
PXI 18 Channel Data Comms MUX, 96-pin SCSI
40-735-902
The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. The 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.
-
product
Battery Testing System
C8000
The Cadex C8000 stands in a class by itself in flexibility and affordable price. Test SMBus batteries, monitor cell balance and capture load signatures to observe batteries with a unique load protocol. Add a thermal chamber, an external load bank, a safety circuit and alarm to form a command center and you begin realizing the unique qualities of this fine battery testing system.
-
product
AC & DC Loadbanks
Regular load bank testing of generators provides an essential health check service to prevent diesel engine failure due to wet stacking. Wet stacking occurs due to under loading of the genset which results in wet un-burned fuel building up in the engine. This fuel build up will over time line the combustion chamber cylinders and cause a reduction of the engines rating and efficiency which will ultimately cause premature failure of the generator. Running the generator on load of 50% - 100% of the genset rating will allow the engine to reach the recommend operating temperature, which will burn off the choke deposits.
-
product
Battery Data Logger
BDL-3926C
Kongter Test & Measurement Co., Limited
BDL-3926C Battery Data Logger is wireless monitoring device for string voltage, cell voltage, current and temperature. It works individually to reflect battery status or co-works with Kongter’s other battery test equipments like battery charger and K-3980 DC load bank. For different battery systems, it has customized configuration from 12V to 480V or upper. And it has easy expansion for all battery systems.
-
product
20KVA to 200KVA Industrial UPS (3Ø – 3Ø)
NSP Series 20KVA to 200KVA
- Designed for powering critical Industrial and IT systems- DSP controlled IGBT based PWM technology- Design topology enables N+1 parallel redundancy- Industrial grade high speed CAN bus communication- User Friendly Matrix LCD and LED mimic front control and digital monitoring- Fully rated make before break maintenance bypass operation- Optional break-less load transfer via static switch- Low harmonic distortion- High crest factor tolerance and dynamic stability- Lower TCO- Continuous full rated power at ambient as high as 45°C- N+1 Parallel operation of UPS without any common hardware- Advanced Communication Capability (RS485/Modbus/SNMP)- High branch fuse clearing capacity- On-line battery bank test without load disconnection- Compact, elegant, and light weight enclosure- Easy installation with wheels for maneuverability and front bottom terminals
-
product
5KVA to 100KVA Industrial UPS (3Ø – 1Ø)
NSP Series 5KVA to 100KVA
- Designed for powering critical Industrial and IT systems- DSP controlled IGBT based PWM technology- Design topology enables N+1 parallel redundancy- Industrial grade high speed CAN bus communication- User Friendly Matrix LCD and LED mimic front control and digital monitoring- Fully rated make before break maintenance bypass operation- Optional break-less load transfer via static switch- Low harmonic distortion- High crest factor tolerance and dynamic stability- Lower TCO- Continuous full rated power at ambient as high as 45°C- N+1 Parallel operation of UPS without any common hardware- Advanced Communication Capability (RS485/Modbus/SNMP)- High branch fuse clearing capacity- On-line battery bank test without load disconnection- Compact, elegant, and light weight enclosure- Easy installation with wheels for maneuverability and front bottom terminals
-
product
Resistive AC Load Bank
AC load bank testing offers you whole solutions of predictive failure analysis for UPS(uninterrupted power supply), generator, transformers, PV system, inverter etc, to validate the condition and output of such power systems comprehensively. Integrated AC & DC load bank could be made in one unit or separately with different load voltages as per your need for different applications.
-
product
PXI 36 Channel Data Comms MUX, 96-pin SCSI
40-735-912
The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. This 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.
-
product
Resistive & Inductive AC Load Bank
RL
Resistive & reactive load banks are able mimic motor loads and electromagnetic devices within a power system as well as purely resistive loads by offering the ability to set a specific power factor (pf). Many backup generators and turbines are rated at 0.7, 0.8 or 0.85 power factor and need to be commissioned at nameplate capacity using a combination of resistive and reactive load to fully qualify their operating capability. Using a resistive & reactive load bank enables comprehensive testing from a single unit. JUNXY has an extensive range of resistive & reactive load banks to simulate these types of loads on a power source and the transformers, relays, and switches which will distribute the power throughout your facility.
-
product
Multi-Unit Controllers
Mosebach Manufacturing Company
Mosebach’s Multi-Unit Controllers are built to help you manage your load banks in operation – whether 10, 20 or 500 units ganged together.
-
product
Battery Load Banks
Kongter Test & Measurement Co., Limited
Kongter offers many different models of battery load units for real capacity test in various industries. With our customized solution, users of different applications will find their exact models as per their needs. With its optional DAC (Data Acquisition Case), you could easily monitor voltage of each cell on PC during battery discharge test.
-
product
Automatic Power Factor Controller
Power factor controlling based on the capacitor bank switching historyCapacitor is automatically disabled when it is deteriorated beyond a certain levelAutomatically learns the number of capacitors connected and the value.Capacitance-based power factor correction takes care of variation in voltage and frequency.Controlling based on VAR parameter and availability of built-in alarms Flexibility for site programmability of CT ratio suitable for any load
-
product
AC Load Bank (Resistive & Inductive)
K-1000 Resistive & Inductive
Kongter Test & Measurement Co., Limited
Kongter resistive & inductive AC load banks are used to simulate the motor loads or other electromagnetic devices working at their rated power factor. Many backup generators and turbines are rated at 0.7, 0.8 or 0.85 power factor and need to be commissioned at nameplate capacity using a combination of resistive and reactive load to fully qualify their operating capability. Using a resistive & reactive load bank enables comprehensive testing from a single unit.
-
product
Load Banks
EL Series
*12kW, 15kW and 18kW DC Electronic Load*All of our Load Banks are continuously rated for Power and Current.
-
product
SMART Constant Current DC Load Banks
SLB-Series
SMART Constant Current DC Load Banks are designed for acceptance testing, discharge testing, battery capacity testing, battery maintenance, engineering examination and other testing for DC power with load. The SMART technology allows a constant current discharge without the need for manual adjustment of current during the discharge test. Our SLB-Series load banks are portable, durable, economic, safe, easy-to-use and come complete with our DataView software, providing the user with a complete data management and analysis program.
-
product
Inductive Load Banks
L-Series
L-series inductive load banks are devices which contain inductive loads, apply the load to an electrical power source and dissipate the reactive power of the electrical source. L-series load banks are designed for portable and fixed applications. Hilkar brand L-series load banks have robust design and are specifically designed for corrosive environments. Load banks can be controlled via local, remote, wireless remote or automatic control systems.
-
product
AC Load Banks
XL1000-XL1250 Series
Mosebach Manufacturing Company
The XL1000-XL1250 Series load banks offer you a continuous load at various voltages in a compact, lightweight enclosure.
-
product
Resistive & Capacitive AC Load Bank
RCD
RCD AC load banks are used to test the REAL working condition of UPS, rectifier, inverter and etc who are loaded by non-linear or electronic load with non-constant resistance such as computer, networking equipments and etc. Through the accurate detection of its output and power quality, users could avoid the inadequate loading capacity or cause pollution to power grid, so as to guarantee supply security. JUNXY RCD load banks leading power factor loads are created to debug power supply system parameters such as its crest factor test.
-
product
Three Phase Load Bank
REOLOAD 310
A three phase load bank rated for 48kW, with fan cooling. The front panel layout includes a switch panel for configuring the separate resistor modules to give the required resistance and current range. There are also digital panel meters for displaying the phase voltages and currents. An interface for PLC control is also provided.