Compensators
-
Product
Flame Ionization Detector
-
A flame ionization detector converts a hydrocarbon gas concentration into an electrical signal. The flame is hydrogen fueled and burns in hydrocarbon free combustion air. Either side of the flame are two electrodes between which an electric field is generated by means of a polarization voltage. The sample is pre-mixed with the fuel gas and heated in the flame to a temperature at which the hydrocarbon molecules ‘crack’ and CH fragments appear. These CH fragments are oxidated by the oxygen in the combustion air resulting in the formation of CHO+ ions. The ion current then passes to the electrodes and the resulting current measured is proportional to the quantity of C atoms derived from organic compounds.The Thermo-FID features two separate microprocessor controlled pressure compensations to avoid any influence from environmental or sample conditions. In addition, the complete Thermo-FID range of analyzers are equipped with a flame trap that is used as a heated sample inlet filter. The measurement chamber and all material in contact with the sample gas are heated between 120°C and 200°C to avoid condensation.
-
Product
Trace-Level UV Fluorescence SO2 Analyzer
Model T100U
-
Teledyne Advanced Pollution Instrumentation
The Model T100U Trace-level SO2 analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. It uses the proven UV fluorescence principle, and is designed to allow ultra-sensitive SO2 measurements while still meeting the requirements for use as a US EPA compliance analyzer.The analyzer uses both the light and dark phases of the pulsed UV light source to continuously detect and correct for electronic noise, giving exceptionally stable and sensitive performance. A separate UV detector allows the instrument to continuously correct for variations in lamp intensity. Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift, and a reference detector to correct for changes in UV lamp intensity. A hydrocarbon "kicker" and advanced optical design combine to prevent inaccuracies due to interferents.
-
Product
Ellipsometer
RC2
-
The RC2 design builds on 25 years of experience. It combines the best features of previous models with innovative new technology: dual rotating compensators, achromatic compensator design, advanced light source and next-generation spectrometer design. The RC2 is a near-universal solution for the diverse applications of spectroscopic ellipsometry.
-
Product
CATV MSA EDFA (1540~1563nm)
HA5700
-
Hangzhou Huatai Optic Tech. Co., Ltd.
Huatai HA5700, the Mid-Stage Access (MSA) CATV fiber amplifier, is developed and produced specially for the dispersion compensation of over-long trunk. HA5700 is composed of lower noise per-amplifier (PA) and booster amplifier (BA). There is access connector between these two amplifiers and thus the dispersion compensation module (DCM) can be accessed in the mid-stage conveniently. It offers the most simple and effective application.
-
Product
Passive Probe, 500 MHz, 10:1, 1 MOhm/10 MOhm
PP020-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
8 Channels, RTD Measurement
RT1
-
The module provides 8 measurement channels, and can be programmed for interfacing to 2, 3, and 4-wire platinum RTD sensor configurations. The 4-wire mode (default) is the most accurate, providing excellent stability and repeatability. The RTD channels feature individual A/D converters and precision excitation/current drive. Programmable lead-wire compensation is provided for inherently less accurate 2 and 3-wire configurations. All RTD channels are self-aligning because each channel is automatically "aligned" on a rotating basis to eliminate offset and gain errors throughout the operating envelope. Programmability for expected resistance range and wire modes allows for optimization of scaling/resolution, as well as flexibility in reading many RTD types.
-
Product
Hot Wire Anemometer
CENTER 332
-
Air Velocity Measurement: m/s, km/hr, ft/min, MPH, Knots & Build In Temperature ºC / ºF, Humidity %RH, Air Velocity Compensation In Atmospheric Pressure, Air Flow Measure: CMM, CFM, Telescoping Hot Wire Probe
-
Product
Closed Loop Precise Hall AC/DC Current Sensor
CYHCS-LF
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for accurate measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor.
-
Product
NI-9211, 4-Channel, 14 S/s/ch, ±80 mV C Series Temperature Input Module
779001-01
-
4-Channel, 14 S/s/ch, ±80 mV C Series Temperature Input ModuleThe NI‑9211 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9211 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
Product
Mid-Range Gas Filter Correlation CO Analyzer
Model N300M
-
Teledyne Advanced Pollution Instrumentation
The Model N300M is a microprocessor-controlled analyzer used to determine the concentration of carbon monoxide (CO) in a sample gas. The analysis method is based on the Beer-Lambert law.The N300M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.
-
Product
VOA DWDM with EDFA With VOA, EDFA Dense Wavelength Division Multiplexer
DWDA-1000 (100GHz)
-
Hangzhou Huatai Optic Tech. Co., Ltd.
Huatai DWDA-1000 series is integrated by DWDM, VOA and EDFA module in a 1RU or 3D rack. Each channel of DWDM with a high-resolution factor electronic control adjustable optical attenuator will adjust and equilibrium the power. The insertion loss, power loss because of the channel equilibrium of DWDM will be amplified and compensation by the build-in gain flatness EDFA. Compact and simple device structure, thereby reducing the connections between devices to improve the index and reliability of the system. Can be used in DWDM system power equilibrium, optical add and drop multiplexed (OADW) flexible and expediently.
-
Product
Decelerometer
-
Maschinenbau Haldenwang GmbH & Co. KG.
National type approval by the PTBPrinter with keyboard and digital displayFast matrix printer with graphic expressionPiezoelectric decelerometersControl and measurement electronicsElectrical equipment adjustment by means of digital displayGyro sensor for automatic compensation of the measurement error by the pitch behavior of the vehicleJacks for pedal force, pressure u. Load indicatorRS-232 interface to PC with data transfer for standard table SoftwareChargerSpare roll of paper approximately 15 mplastic suitcase
-
Product
Handheld Water Quality Meters
LAQUA PH220
-
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers) - 0.01 pH resolution- Offset and average slope display - Automatic / manual temperature compensation and temperature calibration function- ORP calibration option- °C & °F temperature readings- With real-time clock and date/time stamp for GLP compliance- Auto log data; built-in memory can store up to 1000 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached- Monochrome LCD with white LED backlight: 50 x 50 mm- Phono jack output for connecting meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrode and calibration solutions in carrying case- 3 years meter warranty
-
Product
Digital Salinity Refractometer
MA887
-
Thousands of saltwater aquarium enthusiasts have dialed in the analysis with Milwaukee's salinity refractometer. No more visual readings. Get a digital readout within seconds accurate to ±2 ppt with automatic temperature compensation (ATC).
-
Product
SCB-68A, Noise Rejecting, Shielded I/O Connector Block
782536-01
-
68-Pin Female Screw Terminal to 68-Pin Female D-SUB, DIN-Rail, Shielded I/O Connector Terminal Block - The SCB-68A provides a shielded I/O connection for interfacing I/O signals to plug-in data acquisition devices with 68-pin connectors. This Terminal Block combines with shield cables to provide low-noise signal termination. The SCB-68A incorporates a completely redesigned mechanical enclosure with a magnetic removable lid, DIN-rail mount compatibility, and a resettable fuse. It is compatible with single- and dual-connector Multifunction I/O with 68-pin connectors. The SCB-68A also includes two general-purpose breadboard areas and an onboard cold-junction compensation sensor.
-
Product
MAX PH/ORP/Temp Logging Bench Meter
MW151
-
The Milwaukee MW151 MAX 3-in-1 pH/OPR/Temp. Logging Portable Bench Meter has won fans around the world with its reliable, fast and simple operation as well as its tough, sleek design with a small lab footprint. The MW151 MAX is accurate to ± 0.002 pH with automatic or manual temperature compensation with a built in dedicated GLP key. Ideal for use by brewers, wine makers, growers, labs, food processing, water treatment and many other applications with challenging pH measurement needs.
-
Product
Power Capacitors with Protection Filter
CPFVF / CPMVF
-
Lifasa - International Capacitors, SA
The capacitors of the CPFVF and CPMVF series are formed by a power capacitor, an antiarmonic protection reactance and fuse or magnetothermic protection. These capacitors are specially designed for the fixed compensation of transformers in networks with a high level of harmonics.
-
Product
Automatic Battery
BATLV400
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation of power factor in low voltage instalations.
-
Product
Guardian Ground Bond Tester
19572
-
Chroma Systems Solutions, Inc.
Wide resistance measurement range : 0.1 ~ 510 mΩHigh performance AC current output : 45 ACompact size ground bond testerProvide reliable and stable test resultsBuilt-in resistance compensation functionStandard RS-232 interfaceOptional GPIB InterfaceCompatible with the model 19070 series Hipot Tester2-Year factory warranty
-
Product
Ion Chambers
-
0.2 to 5000 mR/hr, 5 Ranges• Temperature Compensated• Retractable 1000 mg/cm² Beta Shield• High Background Zero Capability• Proportional Audio Output
-
Product
MSXB 042
MSXB 042
-
The MSXB 042 Analog Termination Board allows quick and secure connection of discrete wires to the iDSC 1816 Board. MSXB 042 includes locations to install voltage divider resistors and 0-20mA termination resistors, as well as a Cold Junction Compensation (CJC) circuit for thermocouple applications.
-
Product
Compact Eddy Current Sensor System
eddyNCDT 3005
-
Compact and robust design. - Temperature compensation up to 180C. High precision measurement accuracy. High frequency response. Sensor for ferro- and non-ferromagnetic targets. Easy to use (plug & play). Perfect for machine integration.
-
Product
NI-9214, 16-Channel, 68 S/s Aggregate, ±78 mV, Isothermal C Series Temperature Input Module
781510-01
-
16-Channel, 68 S/s Aggregate, ±78 mV, Isothermal C Series Temperature Input Module - The NI‑9214 is a high-density thermocouple input module that is designed for higher channel count systems. The NI‑9214 includes features to increase overall accuracy, such as CJC sensors in the terminal block, component layout to minimize thermal gradients, and an autozero channel for offset error compensation.
-
Product
Beer Refractometer
PA202X-801-802
-
Dual scale Digital Beer Refractometer for measuring °Plato or Specific Gravity (D 20/20) of wort. These beer scales are temperature compensated specifically for wort.
-
Product
Thyristor Switches
SC Series
-
SC Series Thyristor Switches are used in systems which contain fastswitching inductive loads. The capacitors, which will be used to provide capacitive power to the system, can be switched on and off with a switching time shorter than 20 ms (1 period) by using SC Series Static Contactors, thereby providing a more effective compensation for fast-switching loads such as tack welding machines, cranes and arc furnaces.
-
Product
16-Channel VME Analog/Thermocouple Input Module
V450
-
The V450 is a 16-channel 24-bit VME isolated analog-to-digital converter module which can acquire a wide range of DC voltages, including thermocouple readings with automatic cold junction compensation. Each channel is independently isolated with it's own A/D converter, signal conditioning, input protection circuits, and test relay.
-
Product
B-H Analyzers
-
Precise and accurate core loss measurementIwatsu's B-H analyzers which hiring CROSS-POWER method (IEC62044-3)enable precise and highly accurate measurement embedded minimized phase error integration on frequency spectrum with current detecting resisters and compensation on detecting circuit with full compensation on amplitude and phase characteristics.
-
Product
Advanced Line Protection System
ALPS
-
ALPS is a multi-function digital protective relay system intended toprovide distance protection for HV or EHV transmission lines. It maybe applied on or adjacent to series compensated lines. It is availablefor single or three phase tripping applications. Typical operatingtimes are to 1 cycle.
-
Product
NI-9210, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module
785043-01
-
4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module - The NI‑9210 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9210 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
Product
Probe Cards
Minitile™ with Advanced Cantilever™ technology and WedgeTile™
-
Each probe is designed for wide temperature ranges and so the probe expansion characteristics are closely matched to the wafer’s expansion characteristics. This allows the user to take a fast measurement while a system is in a settling or thermal stabilization mode and helps compensate for wafer expansion.