Compensators
-
product
Handheld Water Quality Meters
LAQUA PC210
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display- ORP calibration option- Automatic / manual temperature compensation and temperature calibration function- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater - Auto log data; built-in memory can store up to 500 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached - Monochrome LCD with white LED backlight: 50 x 50 mm- Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty
-
product
Power Capacitors with Protection Filter
CPFVF / CPMVF
Lifasa - International Capacitors, SA
The capacitors of the CPFVF and CPMVF series are formed by a power capacitor, an antiarmonic protection reactance and fuse or magnetothermic protection. These capacitors are specially designed for the fixed compensation of transformers in networks with a high level of harmonics.
-
product
Thermocouple Bench Selector Switches 6 or 12 Way IEC, ANSI
A 6 or 12 way selector in a moulded housing with aluminium front and rear panels. The rear inputs are switched via a front mounted rotary selector switch to the single output socket. Internally wired with thermocouple compensating cable and available with IEC or ANSI thermocouple types K, J, T, N & R/S.
-
product
Cable Length Meter
CLM100
UEi Test & Measurement Instruments
The CLM100 Digital Cable Length Meter is an excellent tool to measure spooled cable/ wire. This best seller is built solid and supplied with a ruggedized boot for reliable field performance. Currently being utilized by major utility companies, electrical contractors, wholesalers, and installers where quick and accurate inventory management or measurements are needed for job accountability. Simply attach the Kelvin Clips to both ends of the cable and adjust the indicator to the size wire being measured. A temperature compensation circuit ensures accuracy by compensating for the temperature of the wire.
-
product
Accuracy
CMM Automatic Temperature Compensation
The Aberlink Temperature Compensation option enables your CMM to maintain accuracy in an uncontrolled environment, such as on the shop floor.
-
product
Bluetooth Enabled® Conductivity/TDS/Salinity/Temperature Pen
UltrapenX2™ PTBT1
Accuracy of ±1% of READING, ±0.2% at Calibration Point. KCl, NaCl and 442 Natural Water™ Modes. Automatic Temperature Compensation. Autoranging. Measurement Storage with Time, Date and Location. Export Stored Measurement Data Via Email. Proprietary Cell Design. Rugged Design with Aircraft Aluminum Body. Durable, Epoxy Encapsulated Electronics. Powered by One N Type Battery (Included). Waterproof.
-
product
pH 700 Benchtop pH Meter
The easy-to-use, microprocessor-based pH 700 benchtop meter measures pH, mV, relative mV, and temperature. The large, dual-display LCD provides excellent visibility—even from a distance. Automatic temperature compensation (ATC) maintains reading accuracy even with fluctuating temperatures. Five-point pH calibration, with automatic buffer recognition for both USA (pH 1.68, 4.01, 7.00, 10.01, 12.45) and NIST (pH 1.68, 4.01, 6.86, 9.18, 12.45) pH buffers, makes for easy calibration no matter which requirement you need to meet. Meter features HOLD, ATC, selectable °F or °C measurement, recall of electrode slopand offset, and electrode diagnostics. The convenient pull-out quick reference card keeps procedures handy at all times. Meter accepts any pH or ORP electrodes with a BNC connector.
-
product
MAX PH/ORP/ISE/Temp Logging Bench Meter
MW160
The Milwaukee MW160 4-in-1 MAX pH/OPR/ISE/Temp. Logging Bench Meter has won fans around the world with its reliable, fast, simple operation as well as a tough, sleek, lightweight design with a small lab space footprint. It is cccurate to ±0.01 pH with automatic or manual temperature compensation, and built in dedicated GLP key. In addition, up to 3-point automatic calibration and 7 selectable buffer standards makes the MW160 MAX ideal for use by brewers, wine makers, growers, labs, food processing, water treatment and many other applications with challenging pH measurement needs.
-
product
Lithography System
JetStep X500
The JetStep X500 panel lithography system is optimized for volume manufacturing of high-end AICS and advanced packaging panels. The system incorporates a large field exposure system with advanced features to meet the challenging requirements encountered in production of AICS or panel level packaging, such as; fine resolution to 3µm with large depth of focus (DOF), high overlay accuracy of ±1µm, automatic magnification compensation with independent x and y magnification adjustment of ±100 ppm, and automatic handling of panel substrates of various dimensions, thicknesses, and levels of warp.
-
product
Precision Capacitance Meter
TH2638C
Changzhou Tonghui Electronic Co., Ltd.
TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.
-
product
sbRIO-9213, Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
781210-01
Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The sbRIO-9213 is a high-density thermocouple input module that is designed for higher-channel-count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The sbRIO-9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The sbRIO-9213 features NIST-traceable calibration and a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.
-
product
Conductivity Meters
There are both standard and a waterproof conductivity meter, as well as a conductivity meter available for flowing water or pure water (highly recommended for specific industries) as well as the ones with different conductivity measurement ranges. An important factor is that a conductivity meter normally measures electric conductivity in µS/cm, however it can also take measurements in mg/l (for direct reading of content in dissolved solid substances). The relation is established as follows: 2 µS/cm = 1ppm (parts per million) = 1 mg/l. Compensated temperature in the conductivity meter can be automatic or by hand.
-
product
Thermocouple Interface Amplifiers
Analog Devices offers specialized precision thermocouple interface amplifiers that provide a simple and effective solution for measuring thermocouple temperatures. With features such as integrated cold junction compensation and a high gain precision instrumentation amplifier, these thermocouple amplifiers provide a complete signal conditioning system in one IC package. ADI’s thermocouple amplifiers are suitable for use in diverse environments to measure a wide range of temperatures. These products will save you in cost, space, and unnecessary circuit design across a broad range of applications and industries.
-
product
Ellipsometer
T-Solar™
The T-Solar ellipsometer combines the best photovoltaic measurement technology into a single system designed specifically for textured samples. Based on the establishedM-2000 rotating compensator spectroscopic ellipsometer, the T-Solar measures hundreds of wavelength across the UV-Visible-NIR.
-
product
CO2 Concentration
H5521
The CO2 measurement is based on a 2-source, 2-beam process. CO2 measurement with long-term stability is guaranteed thanks to the proven non-dispersive infrared (NDIR) CO2 measurement cell. The unique patented auto-calibration procedure compensates for aging of the infrared source and guarantees high reliability, long term stability and eliminates the need of periodical recalibration in the field.
-
product
Dual Wavelength Multimode Light Source
FiberLink 6652
The Fiberlink 6652 Dual Wavelength Multimode Light Source is a cost effective, compact, handheld light source. The temperature compensated outputs are calibrated to couple -20dBm of optical power into multimode fiber.
-
product
Autofocus System
CRISP
Applied Scientific Instrumentation
The CRISP system is designed to maintain focus over time i.e. compensate for thermal & other factors that may cause the sample to drift out of focus over time. It also can be used to maintain a given focal point while scanning the sample in XY. If you are looking to find the optimal focal point while scanning through the sample in Z phase.
-
product
Intelligent Liquid Level Transmitter
HR8000/K/RK
HighReach Measuring & Controlling System Co.,Ltd
HR8000 intelligent liquid level transmitter is an input type liquid level measuring instrument, which realizes full-scale digital linear correction, digital temperature error compensation in full temperature zone, and stores compensation parameters in non-volatile memory, adopting multiple security protection mechanisms. Of the product being unusable due to the loss of the calibration parameters is avoided; the circuit module has the power supply monitoring, the watchdog monitoring function, and the input structure is all stainless steel sealed, which greatly improves the reliability of the product.
-
product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP022-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
Passive Probe, 10:1, 300 MHz, 1.2 M
N2842A
The Keysight N2842A low-cost passive probe provides a 10:1 attenuation and features a high input resistance of 10 MΩ. The probe can be adjusted for low-frequency compensation and high-frequency compensation.
-
product
Acoustic Backscatter Sensor
LISST-ABS
The LISST-ABS is a fixed-point monitoring sensor. It uses a new and novel technique to internally compensate for geometric beam spreading and attenuation, yielding de-attenuated backscatter signal strength. It is held pointing into flow for low drag.
-
product
PXIe-4353, 32-Channel, 24-Bit PXI Temperature Input Module
781348-01
32-Channel, 24-Bit PXI Temperature Input Module—The PXIe‑4353 is a thermocouple input module that provides integrated data acquisition and signal conditioning for temperature measurements. The PXIe‑4353 includes increased accuracy and synchronization features for scalable measurement systems from low‑ to high‑channel counts. The high accuracy is attributed to the NI TB‑4353 isothermal terminal block that optimizes thermal conductivity between the thermocouple terminals and the cold-junction compensation (CJC) channels. The PXIe‑4353 has two auto zero channels for offset compensation as well as open thermocouple detection to identify disconnected thermocouples.
-
product
Insulation Resistance Meter
AMIC-10
The AMIC-10 digital insulation resistance meter is used for direct measurements of the insulation resistance of electrical equipment working with voltage up to 1 kV. In addition, this meter makes it possible to measure compensation and protective connections, low-voltage resistance measurements and DC and AC voltage measurements.
-
product
500 MHz Passive Probe for HDO4000, 10:1, 10 MOhm
PP018-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
Data Collector for Water Levels
DCX-22 AA
KELLER AG für Druckmesstechnik
The data collector DCX-22 AA measures and records ground water levels using KELLER's two sensor AA-technology (absolute-absolute). The submersible depth sensor measures the water level. Barometric pressure variations are measured and compensated with the built-in waterproof air pressure sensor which is mounted in the electronics housing at the top of the borehole.
-
product
Flue Gas Analyzer (Instrument Only)
C160
UEi Test & Measurement Instruments
Backed by UEi Service+ to give up to 6 years’ warranty, next day recertification, and a reduced cost of ownership. The C160 Residential Combustion Analyzer is instrument only, easy to use with a rugged design, multiple sensor protections and altitude compensation. Essential information for installing and maintaining furnaces and boilers all in one device.
-
product
3D SPI Series
MS-15
- Exclusive 15MP / 25MP CoaXPress Camera System- Dual Projection Shadow Free Moiré Technology- Precision Compound Telecentric Camera Lens- Automated Z-Height Calibration System- Automated PCB Under Board Support System- Precision PCB Warpage Compensation- Closed Loop Communication With Screen Printer- Absolute Repeatability and Reproducibility- INTELLISYS® Industry 4.0 Intelligent Factory Automation System
-
product
CAPS True NO2-NOX-NO Analyzer
Model N500
Teledyne Advanced Pollution Instrumentation
The Model N500 CAPS NOx analyzer uses superior Cavity Attenuated Phase Shift (CAPS) Spectroscopy to measure True NO2, NOx, and NO gases. The instrument combines direct NO2 measurements with highly efficient gas phase titration (GPT) to convert and measure the NO gas component. An automatic baseline reference cycle accounts and compensates for any potential baseline drift due to varying environmental conditions.
-
product
Power Potentiostat/Galvanostat
1100C
The Model 1100B series power potentiostat/galvanostat is designed for electrochemical applications that require relatively large current and high compliance voltage, such as battery studies, corrosion, electrolysis, and electroplating. The current range is 2 A, and the compliance voltage is 25 V. The instrument contains a high speed digital function generator, a fast data acquisition system, filters for current signals, iR compensation circuitry, a potentiostat, and a galvanostat (Model 1140B). The potential control range is 10 V.





























