Impedance
-
product
LCR Meters & Impedance Measurement Products
Hewlett Packard, Agilent and Keysight have contributed innovations and product excellence in impedance analysis for over half a century. Whether your application is in R&D, production, quality assurance, or incoming inspection, we take pride in contributing to your success. We strive to deliver complete solutions to meet your needs, from impedance analyzers to a wide variety of test accessories. Achieve success with Keysight’s impedance measurement solutions.
-
product
CATx Surge Protector
SP-CAT5-6V
Protects sensors running on CATx unshielded twisted pair (UTP) cable against the effects of electrostatic discharge, faulty wiring and lightning. The use of two protectors on each end of the line will provide increased protection for each end against surges. Protected pins: (1,2) (3,6) (4,7) and (7,8) pass through. Impedance: 85 to 115 Ohms. Surge suppression: 22Vpeak @ 100A 10/1000µs. Maximum continuous voltage: 6Vpeak. Dimensions WxDxH: 1x3.6x0.9 in (25x91x23 mm). Regulatory approvals: GR 1089, NEC 800.100 and 830.100, ITU 703, UL94 V0 Flame Rated.
-
product
Differential Probe
DP-40K
*MAX. Input Voltage: ±20KV DC or 40KV p-p or AC 14KV rms*Bandwidth: DC-20MHz*Input Impedance 100MΩ// 1PF*x500, x5000 Attenuator*To Ground MAX. Voltage: 10KV CAT III*Output Impedance 50Ω
-
product
Signal Integrity Test Products
RoBAT RCI
*TDR & TDT, Measurement Capabilities*Impedance, Skew, Backdrill measurements*Automated Optical Inspection*DC Electrical Test*Now available with 4 heads*24 port (1 port per channel) TDR/TDT unit*Future capabilities – Fully automated VNA test (4 port S-Parameter Measurement)
-
product
Ammeter
Gill AC
ACM's flagship instrument offers a Potentiostat, Galvanostat and Zero Resistance Ammeter with integrated Frequency Response Analyser and Sweep Generator in one.Electrochemical tests such as AC Impedance (EIS) and standard DC tests including LPR and current and voltage noise are included, making this instrument extremely versatile and great value for money.To better meet your specific needs why not customise your instrument with our options, so versatile are our instruments that many options are even available to be fitted retrospectively, making our instruments the right choice now and for the long term.
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
product
Mini Coax, Contact, ITA, RG178
610103157
Mini Coax, Contact, ITA, RG178.Mechanical SpecificationsDurability 20,000 cyclesContact Material Center conductor – BeCuShield – BrassContact Plating Shield 50µ" Au over 100µ" NiCenter Conductor – 60µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC to 1 GHzVSWR ≤ 1.06 @ 1 GhzInsertion Loss 1.2 dB @ 1 Ghz1.02 dB @ 500 MhzDWV 1500 VDC Min.Contact Resistance < 5 milliohms @ 0.5 Amp & always < 10 milliohmsCable Specifications RG178Environmental SpecificationsOperating Temperature -50C to +105CInsulation Resistance 1000 MΩ min.
-
product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L-QG
Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 0.80Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
product
Transducer Simulator
Model 0V
SPECIFICATIONS: Impedance: 700 ohms nominal. Output Ranges: 10 turn vernier 0 - 3mV/V. Excitation: 20v ac/dc max,
-
product
Potentiostat Galvanostat
1287A
The Solartron Analytical 1287A potentiostat and galvanostat is a high accuracy, wide bandwidth instrument which offers a range of DC test capabilities. The 1287A can be coupled with a frequency response analyzer, such as the Solartron Analytical 1260A or 1255B, and ZPLOT software for AC tests such as Electrochemical Impedance Spectroscopy.
-
product
Differential Probe
DP-16V
*MAX. Input Voltage: ±8KV DC or 16KV p-p or AC 5.6KV rms*Bandwidth: DC-50MHz*Input Impedance 30MΩ// 1.5PF*x20, x200, x2000 Attenuator*To Ground MAX. Voltage: 8KV CAT III*Output Impedance 50Ω
-
product
Vector Network Analyzers
RF VNA to a Broadband VNA, from a Premium VNA with the highest performance and no compromises to a Value VNA that offers solid performance with suitable measurement speeds for an R&D environment. No matter what your application, Anritsu has your VNA needs covered. Choose with confidence from the pioneers in VNA measurements, introducing the Wiltron 310 Impedance Meter in 1965, and introducing the first broadband VNA, spanning 40 MHz to 65 GHz, in 1999. The first to cover a span from 40 kHz to 125 GHz from a single coaxial connector.
-
product
Micro Coax, Contact, ITA, RG316
610141101
Primary mating contact 610140101. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 50µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC – 3 GHzVSWR 1.22 @ 3 GHzInsertion Loss – √f(GHz) x .06 dBDWV 800 V RMSContact Resistance 6 mOhms center/4 mOhms outer Cable Specifications RG316Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Micro Coax, Contact, Receiver, RG316
610140101
Primary mating contact 610141101. (May mate with other ITA contacts, as well.)Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 50µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC to 3 GHzVSWR 1.22 @ 3 GHzInsertion Loss – √f(GHz) x .06 dBDWV 800 V RMSContact Resistance 6 mOhms center/4 mOhms outerCable Specifications RG316Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
WavePulser 40iX High-speed Interconnect Analyzer
WavePulser 40iX Series
WavePulser 40iX is the ideal single measurement tool for high-speed hardware designers and test engineers. The combination of S-parameters (frequency domain) and Impedance Profiles (time domain) in a single acquisition with a deep toolbox provides unmatched characterization insight of high-speed interconnects.
-
product
Calibration Kit
S911T
*S911T Calibration Kit, * Frequency Range: up to 9 GHz, * Impedance: 50 Ohm, * Connector Type: 3.5 mm female.
-
product
Amplifier, Switch and Test Box
CLIOQC Model V
The QCBOX Model 5 is a non-conventional unit designed to fulfil actual and future needs of an electro-acoustical analyzer like the CLIO system. It is USB linked to a PC and can be configured, with dedicated software controls, to assist frequency response and impedance measurements or to perform DC measurements. Using it for frequency response measurements acts as 50W power amplifier to drive the speaker or network under test while routing one-of-four inputs to the analyzer as well the current sensing output. The four inputs are able to provide a phantom power supply both for Audiomatica or general purpose microphones (0-24 V range, software controlled). Impedance measurements can be done either switching the D.U.T.’s load across the analyzer’s input or using a dedicated output, ISENSE, thus allowing impedance measurements in constant voltage mode as well voice coil current distortion analysis. An internal ADC measures the DC current into the voice coil. Thanks to an internal software controlled voltage generator the speaker can be driven with a superimposed DC voltage (±20V), allowing for measurements of large signal parameters. Two ADC converters with a ±2.5 V and ±5 V are available at inputs 3 and 4 to measure the displacement with a laser sensor or any other DC signal. A dedicated digital input handles an external foot pedal switch (or TTL signal) to be connected and triggers QC operations. A 6 bit output – 5 bit input TTL digital port is available to interface the QCBOX and driving software with external hardware (like turntables for example).The QCBOX Model 5 finds use both in laboratory for R&D applications and in production lines setups.
-
product
Impedance Matching Pads
These impedance matching pads are resistive networks that can be used to match 2 devices with different nominal impedances. The resistive network used in these impedance matching pads has a 5.7db theoritical insertion loss; true loss is 5.7db plus the normal other losses. common use is to connect 50 ohm sma's to 75 ohm f's. There are also 75 ohm versons of N's, BNC's, & SMA's.
-
product
IDM+
Multi-functional fault recorder including: -- Disturbance fault record (DFR)- Dynamic disturbance recording (DDR) - Phasor measurement unit (PMU C37-118)- Power Quality (PQ Class A)- Travelling wave fault location (TWS to +/-60m) - Impedance fault location- Protocols (61850, Modbus, DNP3) - Sequence of event recording (SOE)- GPS, IRIG and NTP time sync- iQ+ masterstation software.
-
product
Calibration Kit
N1802
N1802 Calibration Kit, Frequency Range: up to 18 GHz, Impedance: 50 Ohm, Connector Type: N-type Male
-
product
Micro Coax, Contact, ITA, RG178
610141102
Primary mating contact 610140102. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 50µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC – 3 GHzVSWR 1.22 @ 3 GHzInsertion Loss – √f(GHz) x .06 dBDWV 800 V RMSContact Resistance 6 mOhms center/4 mOhms outer Cable Specifications RG178Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Impedance Analyzer / LCR Meters
When used together with the PSM range of frequency response analyzers, the N4L impedance analysis interfaces provide a measurement solution to many impedance analysis applications. The most appropriate interface for a specific application will depend upon the nominal impedance of the sample or device being tested and the frequency of measurement and N4L will be happy to discuss the optimum soution to any application. Reasons to choose an N4L Impedance Analyzer
-
product
Coax, Contact, ITA, 75 Ohm HD, sm59/U Belden 1855A, 3 GHz
610102132
Primary mating contact 610102133. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – brassCenter contact – BeCuContact Plating Center conductor shield –30µ” Au over 100µ” NiContact Termination Center conductor - SolderShield - CrimpInsulator PTFEMating Force 2.0 lbs max [0.91 kg]Electrical SpecificationsCharacteristic Impedance 75 ΩFrequency Range DC to 3 GHzVSWR ≤ 2.26 @ 3 GHzInsertion Loss -0.86 dB MaxDWV 800 VDC min.Contact Resistance 5 mΩ center/ 3 mΩ outer Cable Specifications sm59/U Belden 1855AEnvironmental SpecificationsOperating Temperature -55°C to +125°CVibration MIL-STD 1344, Method 2005, Test Condition 4Shock MIL-STD 1344, Method 2004, Test Condition AInsulation Resistance 1000 MΩ min.
-
product
Standard 6.20 (175.20) - 8.00 (226.80) High Frequency Probe
CSP-40A-015
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 275 (6.99) including travel of probes
-
product
Impedance Stabilization Networks
ISN
They are required for the measurement of conducted common mode noise on Telecom Cables of Information Technology Equipment (ITE). These measurements are necessary to meet the requirements specified in CISPR 22 and CISPR 32 standards.
-
product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40A-024
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 225 (5.72) including travel of probes
-
product
Concrete Tester & Surveyor
CTS-02V4
CTS-02V4 (Concrete Test and Surveyor) is a Non-destructive testing device for estimation of compressive strength of concrete. CTS estimates the compressive strength of concrete based on Mechanical Impedance Method by measuring a waveform of impact force with an accelerometer which mounted on the hammer unit.
-
product
High Impedance Active Probes
34A
Engineered to meet the stringent demands of advanced high frequency circuit designers. This high impedance probe combines full DC capability, rise/fall times of 120 ps, and a nominal loading input impedance of 10 megohm shunted by 0.1 pf. Signal attenuation is 20:1 with a 50 ohm oscilloscope input.





























