Impedance
-
Product
Calibration Kit
S911T
-
*S911T Calibration Kit, * Frequency Range: up to 9 GHz, * Impedance: 50 Ohm, * Connector Type: 3.5 mm female.
-
Product
Audio Multimeter
AMM-1
-
The purpose of this tool is to enable the user to: Measure True Amplifier Power output into any load reactive or resistive Measure Common DC voltages Measure DC voltage drops during quick transients on cable runs or battery / charging systems Measure Impedance of speakers at any power or frequency from 20Hz - 1kHz (box rise) Measure Phase Difference between Voltage and Current into reactive loads (Power Factor) Find Tuning Frequency of subwoofer enclosures Tune subwoofer enclosures for maximum power transfer Measure AC Volts (amplifier output) Measure AC Amps (amplifier output)
-
Product
Impedance Spectroscopy
NuVant EZware-EIS Software Package
-
The NuVant EZware-EIS software package activates Electrochemical Impedance Spectroscopy on the EZstat-Pro, Powerstat-05 and -20 potentiostat/galvanostats. EZware-EIS exports the impedance data to a file format to accommodate free third party EIS analysis software. EZware-EIS is a user-friendly interface that allows selection of the proper scanning parameters, collect the impedance spectra, display data in Nyquist and/or Bode plots and export data in the proper data format for use in EIS analysis software.
-
Product
Signal Integrity Studio, Analysis & Simulation SW for WAVEPULSER High-Speed Interconnect Analyzer
WavePulser-Signal Integrity (SI) Studio
-
WavePulser Signal Integrity (SI) Studio is included as a single license in the WavePulser 40iX-BUNDLE or can be purchased as an additional license for offline access to additional users. WavePulser Signal Integrity (SI) Studio combines S-parameter, Impedance profiling and de-embedding measurements, channel and equalizer modeling, eye diagrams and jitter analysis in a single affordable software package for emulating the complete serial data channel.
-
Product
Impedance Matching Pads
-
Surface mount and coaxial 50 Ohm / 75 Ohm impedance matching pads for CATV systems, broadband networks, test setups and more!
-
Product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40L-013
-
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
Product
Impedance Analyzers
-
A/D converted input signals undergo discrete Fourier transform (DFT) to calculate complex impedance values and obtain parameters and characteristics specific to the DUT, such as its capacitance, inductance and quality factor. Original NF algorithms are also applied to allow equivalent circuits made up of R, L and C along with the constants for those circuits to be estimated from the complex impedance spectrum obtained by sweeping the frequencies.
-
Product
Materials Test Systems
-
An impedance analyzer is a device that uses a programmable AC voltage / current source, together with voltage and current measurement circuits, to characterize sample impedance over a wide range of frequency. An example of this being the world famous Solartron Analytical 1260A Impedance Analyzer that provides EIS impedance characterization over more than 12 decades of frequency from uHz to tens of MHz. Impedance Analysis characterization is a key technology that enables new materials development for semiconductors, smart-materials, ferroelectrics, piezo-electrics, solid oxide, solid electrolytes, ceramics, polymers, OLED and many more materials.
-
Product
Transducer Simulator
Model 7
-
Impedance: 350 ohms nominal. Output Ranges: Fixed rotary switch. 0 to 3 mv/v in 6 steps of .5 mv/v .
-
Product
Controlled impedance test system
CITS900s4
-
CITS900s4 is the seventh generation of Impedance test system from polar, and typically the most popular model for customers who are new to impedance control. CITS900s4 provides both differential and single ended measurement capability along with 4 channels to provide flexible probe connection.
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75R
-
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
Product
Impedance Monitors
-
Single channel impedance monitorA flexible frequency generator/analyzerSupporting external load/potentiostat - TDI Dynaload RBL488 series & XBL series - WonATech WEL Load - Other 3rd parties potentiostat/galvanostat