Flux
the rate of flow.
-
Product
Photometric Probes for Illuminance
LPPHOT03… Series
-
The probe LPPHOT03 measures illuminance (lux), defined as the ratio between the luminous flux (lumen) passing through a surface and the surface area (m²). The spectral response curve of a photometric probe is similar to the human eye curve, known as standard photopic curve V(λ). The difference in spectral response between LPPHOT03 and the standard photopic curve V(λ) is calculated by means of the error f’1.
-
Product
Digital Tesla Meter
HT208
-
Model HT208 digital teslameter is controlled by the SCM,which is suitable for handle operation.It can be used to measure DC or AC magnetic field and flux dencity.The device can be carried on one’sperson. It is characterized by its wide measuring range,simple operation and clear display. It is still added with the function of maintenance such as holding Measure Value/Peak Value,As mT or Gs unit of display can be change over,Measuring range of 200mT or 2000mT can be choosed,and others that as reseting zero by key and so on. The power is one piece of battery 9V. It can be used continually about 20 hours
-
Product
Underwater Quantum Sensor
LI-192
-
The LI-192 Underwater Quantum Sensor measures PAR from all angles in one hemisphere. The LI-192 works in air or underwater at depths up to 560 meters. The measurements are cosine corrected and typically expressed as Photosynthetic Photon Flux Density (PPFD). For simultaneous measurements of downwelling and upwelling PAR, two sensors can be mounted on the 2009S Lowering Frame.
-
Product
RGB Laser Illuminance, Luminance & Optical Power Meters
TM6102/TM6103/TM6104
-
Accurately evaluate the white balance of displays that use lasers by measuring centroid wavelength and optical power, which are key characteristics in the evaluation of laser light sources. Designed to adjust and inspect RGB lasers. Meters measure radiant illumination, centroid wavelength, illuminance, luminance, chromaticity, Radiant flux (optical power) and luminous flux.
-
Product
PCE-2000UV_1.5 Ultraviolet Light Radiation Measurement System
-
Hangzhou Everfine Photo-E-Info Co., LTD
PCE-2000UV UV light source radiation Measurement system can realize the measurement of the relative spectral power distribution of ultraviolet LED, UV fluorescent lamp, UV light source, peak wavelength, half-peak wavelength, spectral radiation flux of UV-A/B/C, and the total radiation flux in specific wavelength.
-
Product
Continuous Magnetic Measurement Equipment
CWM
-
The automatic measurement equipment to continuously measure magnetic property in commercial power frequency of magnetic steel sheet sample on line, is used for quality control. Core loss in definite time of magnetic flux density [B] or magnetic flux density [B] in definite time of strength of magnetic field [H] for excited magnetic steel sheet is measured on line.
-
Product
Auxiliary Lamp
RLS-50W
-
Due to the luminaries self-absorption, the auxiliary lamp is used to correct the flux test value. Work with the follow instruments as a System
-
Product
Motor/Gasoline Engine RPM Detector
OM-1500/1200
-
The OM-1500/1200 motor/gasoline engine RPM detector is designed for rotation measurement of a gasoline engine and an EV/HEV motor. It detects magnetic flux leakage from the motor itself or the engine’s ignition coil.This easy to use and durable detector can measure engine rotation by attaching in parallel with the ignition coil. When the EV/HEV motor rotation is measured, attach the OM-1500/1200 perpendicular to the motor rotating shaft.It is used with the engine tachometer by Ono Sokki (GE-2500, AR-7240B, CT-6520B, HT-6200, SE-1620, FT-2500, FT-7200).
-
Product
GO-SPEX500 Goniospectroradiometer
-
Hangzhou Everfine Photo-E-Info Co., LTD
Suitable for all kinds of indoor lamps, flood lamps, road lighting lamps and all kinds of light distribution performance test, total luminous flux, luminaire efficiency and electrical parameters (voltage, current, power, power factor) measurement.Test data can be saved as IESNA(*.ies), CIBSE(*.CIB), EULUMDAT(*.LDT), CIE(*.cie), CEN(*.cEN) and other formats, which can be directly used as the input data of international general lighting design software.
-
Product
Advanced Handheld Tachometer
FT-7200
-
The FT-7200 Advanced Tachometer is an easy-to-use handheld digital tachometer offering high functions and performance. The use of FFT (Fast Fourier Transform) technology enables the FT-7200 to perform frequency analysis of rotation speed by using change of signal in sound, vibration or magnetic flux from rotating machines such as a motor or the like. Selection from 5 kinds of measurement modes allows it to calculate and display rotation speed of any complex waveform signals from a sound level meter or an accelerometer accurately by extracting the exact frequency component.
-
Product
Fluxmeter
-
Measure total flux in industrial and measurement system settings—ideal for magnet testing and sorting and as the main component in BH loop or hysteresisgraph measurement applications.
-
Product
Fluxmeters
-
Flux meter has been the established standard for the measurement of magnetic flux density for determining total flux in a magnet or magnetic assembly. Its use was curtailed except in a few specialized areas because of many factors such as the difficulty in setting up light beam flux meter or ballistic galvanometers, limitations on the ohmic resistance of search coils, the requirement of some degree of operator skill in reading the flux meter etc. The development of the integrating type Digital Flux meter has virtually cancelled the hitherto negative aspects of fluxmeterology and has found a broad niche for many magnetic measurement applications.
-
Product
Signal Analysis
Cross-Spectrum FFT Analysis
-
The program Cross narrow-band spectrum is used for evaluation of the interrelation between the signals’ parameters obtained from the two primary transducers installed at various parts of the controlled object. This program can be used for detection of noise source location, for sound absorption level evaluation and the researched object acoustic properties control, for evaluation of space-time distribution of the directional energy flux (Poynting vector), for the ground cross-section FR characteristic evaluation (Nakamura method), etc.
-
Product
Integrating Sphere Systems
-
An optical device for various purposes such as. measuring the radiant flux (optical power) from a laser diode, light-emitting diode (LED) or bulb.
-
Product
LIMES 2000
-
LMT LIMES 2000 software for WINDOWS for measurement and evaluation of light and color distribution or luminous flux with LMT goniophotometers or other photometric instruments
-
Product
Irradiance Probe
LPUVC01
-
The LPUVC01 probe measures irradiance (W/m2) defined as the ratio between the radiant flux (W) passing through a surface and the surface area (m2) in the UVC (200 nm…280 nm) spectral range.
-
Product
Photometers & Colorimeters
-
Instrument Systems Optische Messtechnik GmbH
A photometer is used to measure the photometric quantities of illuminance (lx), luminous intensity (cd), luminous flux (lm), and luminance (cd/m²). The integral method and the fast response time of silicon photodiodes means that photometers can achieve an outstanding measuring speed. They are therefore ideal for performing fast goniophotometric measurements. We take great care in the development and production of photometer heads and use innovative amplifier technologies.
-
Product
Fluxmeter
-
Measures changes in magnetic flux, as detected through a Helmholtz or similar coil arrangement.
-
Product
Standard Light Source
SLS-50W
-
OSRAM Standard Lamp to calibrate the spectrum and luminous flux with Lisun Lab certification. The data can be traced NIM. The Standard Lamp Source is used to calibrate the integrating sphere system. The different size of Integrating Sphere should choose the right power of standard lamp source.
-
Product
CAS-200 Compact Array Spectrometer
CAS-200
-
Hangzhou Everfine Photo-E-Info Co., LTD
CAS-200 can quickly and accurately measure the spectral power distribution in the range of 380nm ~ 780nm, mainly measuring: the relative spectral power distribution, chromaticity coordinate, color temperature, color rendering index, color tolerance, peak wavelength, FWHM, luminous flux (with integrating sphere) of traditional lamps/light sources, single LED, LED modules and other electric light sources.
-
Product
Hall Effect Measurement system
HMS-3000
-
Hall Effect Measurement System is very useful for measuring Carrier Concentration, Mobility, Resistivity and Hall Coefficient that should be pre-checked in order to grasp the electrical specifications of semiconductor device. Therefore, it is essentially required system to understand the electrical characteristics of semiconductor device.Ecopia’s HMS series consist of constant current source , terminal conversion system by Van der Pauw technique, low temperature(77K) test system and magnetic flux density input system. So, it is well-established system that has all the things needed to Hall Effect Measurement System.
-
Product
Hall probes
-
Axial, transverse, multi-axis, and tangential Hall probes for measuring magnetic flux density. Choose from a wide range of lengths and thicknesses—probes are also available for cryogenic applications.
-
Product
5cc Dual Dopant Source
-
Attain precise and stable control of relatively low fluxes for dopant constituents in molecular beam epitaxy (MBE) through this compact dopant source. Its small thermal mass gives it excellent responsiveness, reproducibility, and stabilization for advanced doping profiles, plus consistent flux uniformity across an entire platen. Efficient cell heating minimizes thermal load.
-
Product
Magneto-Electric Rotation Detector
MP-981/AP-981
-
The MP-981 is a magneto-type detector using a hall element which is suitable for revolution (r/min) measurement from low speed to high speed.Magneto-type detectors use an internal hall element, a permanent magnet, DC amplifier, and voltage regulator and respond to flux, so that a rectangular wave form is derivable from much lower speed all the way though high speed.In addition, a signal indicator is provided in spite of the detector's compact design, making verification of operation and mounting position possible.Meanwhile, the AP-981 is the water and acid proof type, which conforms to Class ' of JIS C0920.
-
Product
Single-Stage Current Sensors
-
The robust low-noise single stage current sensors are available with input inductances from 24 nH to 1.8 µH and a flux noise of 1.2 µPhi0/sqrt(Hz).
-
Product
Dosimeter-Radiometer
MKS-05 Terra
-
Measurement of gamma and X-ray radiation ambient dose equivalent rate.Measurement of gamma and X-ray radiation ambient dose equivalent.Measurement of surface beta-particles flux density.Measurement of dose equivalent accumulation time.Real time measurement (clock).
-
Product
Flux Meter and Measuring Coils
-
MAGNET-PHYSIK Dr. Steingroever GmbH
The measurement of magnetic quantities can almost always be traced back to the measurement of a magnetic flux. The electronic fluxmeter is therefore the most versatile measuring instrument in magnet technology as a measuring instrument for magnetic flux. The fluxmeter is operated together with a measuring coil.
-
Product
Reference Magnet
-
Reference magnets generate a homogeneous magnetic field in an air gap. They are mainly used to calibrate hall probes for their full scale value of output for the magnetic field strength H or the magnetic flux density B they measure. For example Gaussmeters can be calibrated by using reference magnets.
-
Product
Multi-omics Analysis Package
-
The Multi-omics Analysis Package, developed for metabolic engineering applications, provides the ability to automatically generate metabolic maps and perform a variety of data analysis for the vast data generated in fields like metabolomics, proteomics and flux analysis. It offers a powerful platform to support drug discovery, bioengineering and other life science research applications.