Working Standards
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2X
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Standard 0.70 (2.00) - 1.70 (4.80) General Purpose Probe
P2662AG-1Q1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
Product
Standard 1.00 (28.00) - 2.75 (78.00) Non Replaceable General Purpose Probe
E-S-F
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 65Full Travel (mm): 1.65Recommended Travel (mil): 43Recommended Travel (mm): 1.09Overall Length (mil): 495Overall Length (mm): 12.57Rec. Mounting Hole Size (mil): 67Rec. Mounting Hole Size (mm): 1.70Recommended Drill Size: #51Overall Length Remark: Overall length for E-S-V and E-S-W is .540 (13.72)
-
Product
Pioneer Standard Cabinet
-
The Pioneer rack is the cornerstone of our broadcast cabinet line, offering flexibility, versatility and strength. Pioneer racks are offered in more than 25 different sizes, creating hundreds of configuration possibilities.
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3G
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Decade Resistance Substituter Lab Standard
HARS-LX Series
-
The HARS-LX substituter is a precision resistance source with excellent characteristics of accuracy, stability, temperature coefficient, and power coefficient. All these features serve to make it a laboratory resistance standard, exceeded in performance only by stand-alone standard resistors.
-
Product
Standard 1.00 (28.00) - 3.20 (91.00) General Purpose Probe
P2550-8
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,453Overall Length (mm): 36.91Rec. Mounting Hole Size (mil): 126Rec. Mounting Hole Size (mm): 3.20Recommended Drill Size: #30 or 3.20 mm
-
Product
Viscosity Standards
-
Brookfield Viscosity Silicone and Oil Standards provide a convenient, reliable way to verify the calibration of your Brookfield laboratory viscometer/rheometer.
-
Product
Standard Ratio Box For Calibration
ST-105
-
The ST-105 is a calibration box with standard ratios. It is used for calibration of any turn ratios measurement system. Housed in a rugged, waterproof case, it is very lightweight.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1P-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Pyranometer First Class standard (ISO 9060 / WMO)
CMP 6
-
The CMP 6 pyranometer is intended for routine global solar radiation measurement research on a plane/level surface.Fully compliant with ISO-9060 specification for a First Class pyranometer, the CMP 6 features a sixty-four thermocouple junction (series connected) sensing element. The sensing element is coated with a highly stable carbon based non organic coating, which delivers excellent spectral absorption and long term stability characteristics
-
Product
Multiparameter CTD with a Wide Choice of Standard Sensors.
MIDAS CTD+
-
Featuring Valeport’s latest 400 Series electronics, the CTD+ will sample all fitted sensors at exactly the same instant, at up to 8Hz. Advanced setup software allows a variety of sampling regimes including burst modes, delay starts and conditional sampling. Available with up to 64Mbyte memory and internal battery pack, as well as a selection of real-time output formats, the CTD+ may be used with Valeport’s own water bottle carousel.
-
Product
NanoCD Standards (NCD)
-
The NanoCD™ (NCD) is the first commercially available standard to provide line width accuracy calibration at the 45 nm, 65 nm, 90 nm and 130 nm nodes. Use these standards for tool matching, calibrating the width of a CD-AFM tip, or CD-SEM diagnostics.
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF800
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation ofpower factor in low voltage instalations
-
Product
Conformance Calibration Standard Test Card for ISO/IEC Data Matrix and GS1 DataMatrix Symbol Verifiers
AI-CCS-DM-G Rev A
-
This precision 2D barcode Conformance Calibration Standard Test Card is the first 2D test card to provide ALL 12 of the Primary Reference Symbols specified by ISO 15426-2 for barcode verifiers. They are sized from 0.5mm to 0.2mm so that all the symbol sizes specified in Annex A.3.1 can be tested. Symbols 1-4 are GS1 DataMatrix symbols, while symbols 5-12 are ISO/IEC Data Matrix symbols consistent with the ISO/IEC 16022 standard. The card also includes four calibrated reflectance patches.
-
Product
Standard - 1.44 (41.00) - 4.50 (128.00) High Current Probe
HCP-13P
High Current Probe
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 2.90 (82.20) - 5.40 (153.00) Switch Probe
TSP157-C100-1
Switch Probe
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 20Test Center (mil): 157Test Center (mm): 3.99Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 984Overall Length (mm): 25.00Switch Point (mil): 67Switch Point (mm): 1.70
-
Product
Standard 1.09 (31.00) - 4.50 (128.00) Long Travel Bead Probe
BPLT-1F-4.5
Bead Target Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,450Overall Length (mm): 36.83Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, High Spring: 350 mil / 8,89 mm
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1T1-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Additional Products: Standard Voltage 50 Pin D-Type Cables - Connector to Unterminated
-
The connector to unterminated cable assemblies below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
Product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-7
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
Product
Standard 1.17 (33.20) - 4.50 (128.00) Battery Probe
CP-2TB-8
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 88Full Travel (mm): 2.25Recommended Travel (mil): 78.7Recommended Travel (mm): 2.00Overall Length (mil): 315Overall Length (mm): 8.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-H180-1
Switch Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1D
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Standard Gain Horns
-
Standard gain horns can be used to experimentally determine the gain of other antennas by using the substitution method. The standard gain horn and the antenna under test are alternately connected to a well matched detector system in order to compare their relative power levels. The power level difference is then added to the appropriate level of the calibration curve to determine the absolute gain of the antenna under test.View more Standard Gain Horn Antennas
-
Product
Dynamic Primary Transfer Standard
RD-22
-
The RD-22 Dytronic Primary Transfer Standard represents the state-of-the-art technology in a commercially available true DC to AC accuracy transfer reference. The RD-22 has typical AC measurement accuracies within the limits of traceability. Repeatability of 1 ppm can be attained at 120 V and 5 A inputs of specific models.
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25H-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
VXI Rubidium/GPS Frequency Standard
3352A Series
-
The Racal Instruments™ 3352A Rubidium frequency standard module and the 3352A-GPS, its GPS-disciplined companion, set a new standard for high density functionality in a single width VXI module. Using ANSI Standard M-Module building blocks, the 3352A series integrates the functions of a Rubidium oscillator and clock distribution together with an optional trigger distribution module and an optional digital I/O (DIO) module.
-
Product
Standard Mechanical Calibration Kit, DC To 9 GHz, 3.5 Mm
85033E
Mechanical Calibration Kit
85033E Standard Mechanical Calibration Kit, DC to 9 GHz
-
Product
Vision Standard IP Cores
-
S2I’s Vision Standard IP Cores solutions are delivered as a working reference design along with FPGA IP cores. This minimizes development time and allows for top-notch performance at a small footprint, while leaving enough flexibility to customize the design. Sensor to Image cores are compact and leave enough space in the FPGA for your application.