Filter Results By:
Products
Applications
Manufacturers
-
product
Bresle Salt Kit
138
The Elcometer 138 Bresle Kit includes the Elcometer 138 Conductivity Meter. This lightweight, portable conductivity meter accurately measures the salinity of the test samples.The cartridge type sensor can be easily replaced when necessary and displays conductivity in a range of units including: S/cm, S/m, ppm and % salinity.
-
product
Semiconductor
Scientific Computing International
Materials which have a conductivity between conductors (generally metals) and nonconductors or insulators
-
product
Field thermal needle system for thermal resistivity / conductivity measurement
FTN01
Hukseflux Thermal Sensors B.V.
The FTN01 Field Thermal Needle System allows performing fast, on-site measurements of the thermal resistivity or conductivity of soils, in particular around the typical depth of burial of high voltage cables. FTN01 is designed with a focus on robustness and saving time, while still offering sufficient accuracy for typical field measurements. The sensor is a Non-Steady-State Probe (NSSP), TP09, which is mounted at the tip of the Lance LN01. The system is operated using a hand-held Control and Readout Unit CRU01.
-
product
Non-Contact (Pulse-Voltage Excitation Method) Ultra-Low Sheet Resistance Measurement System
PVE-80
*No damage measurement by non-contact Pulse-Voltage excitation method*Easy to measure & carry around, Removable stage plate*Easy operation and data processing by PC with Software*Measurement result can shown by 3 types of measurement unit (Sheet resistance[Ohm/Sq], Electric conductivity[S/cm], Electrical conduction[S])*Pulse-Voltage excitation method : Pat. No.5386394 Joint development with Chiba Univ.
-
product
Membrane Hydrophones
Precision Acoustics’ manufactures high-quality co-planar membrane hydrophones which have been developed to satisfy the stringent requirements of MHz ultrasound measurements. The differential membrane hydrophone model is suited to the most demanding, wide bandwidth measurements situations but requires water with very low conductivity.
-
product
Starter Pen Meters
precision is now available in a line of pen meters that provide accurate measurement of pH, oxidation-reduction potential (ORP), conductivity, salinity, and total dissolved solids (TDS).
-
product
Online Conductivity Controller
LD-LOCC-A10
Online Conductivity ControllerLD-LOCC-A10features 3 points conductivity calibration system, TDS measurement mode, and 4 to 20 mA output signal transmitter. The large and clear back light LCD displays Calibration and setup values, Temperature values, ATC (automatic temperature compensation) values, high and low limit of measurement. This controller measures Conductivity and TDS values in µS/ cm, and mS/ cm units.
-
product
Ground Continuity Tester
HTDT-10A / 740
Wuhan Huatian Electric Power Automation Co., Ltd.
It is suitable for testing the conductivity of the connecting part of power equipment and ground network in engineering test of power department.
-
product
Biosensor isoPod
EP352
A compact signal conditioner for monitoring low current, two-electrode (anode and cathode) amperometric sensors.Electrical isolation ensures that readings are not influenced by nearby current sources such as conductivity, or voltammetric electrodes.
-
product
Analytical Services
Atomic Force Microscopy (AFM) allows for sub nanometer resolution imaging of surface topography and is able to quantify surface roughness at the angstrom scale. Our team can give you highly accurate measurements such as surface topography, dopant distribution, magnetic domain features, and a wide variety of other sample properties to give you the information you need to do great work.Park can provide measurements in the following areas:● Topography (surface roughness, grain size, step height, etc.)● Mechanical Properties (stiffness, etc.)● Electrical properties (capacitance, conductivity, etc.)● Thermal properties ● Magnetic properties These properties can be measured in air or liquid, depending on your needs.
-
product
PXIe-4353, 32-Channel, 24-Bit PXI Temperature Input Module
781348-01
32-Channel, 24-Bit PXI Temperature Input Module—The PXIe‑4353 is a thermocouple input module that provides integrated data acquisition and signal conditioning for temperature measurements. The PXIe‑4353 includes increased accuracy and synchronization features for scalable measurement systems from low‑ to high‑channel counts. The high accuracy is attributed to the NI TB‑4353 isothermal terminal block that optimizes thermal conductivity between the thermocouple terminals and the cold-junction compensation (CJC) channels. The PXIe‑4353 has two auto zero channels for offset compensation as well as open thermocouple detection to identify disconnected thermocouples.
-
product
Conductivity Meters
GAOTek conductivity meters report the conductivity of a substance as an inverse function of resistivity. Resistivity is measured in ohms/cm, while conductivity is measured in mhos/cm. Our portable conductivity meters and testers are ideal for water conditioning, medical, beverage, laboratory, and other industrial applications. Our high-performance conductivity meters are reliable, high quality, accurate and affordable equipment that facilitate easy inspection and testing. They are compact, portable instruments that allow a user to conveniently work in complex conditions in a lab or onsite.
-
product
Explosion-Proof Gas Analyzer
51 Series
HORIBA’s 51 Series of explosion-proof analyzers provide safe, reliable and accurate measurements when analyzing flammable gases or operating in explosive environments. The 51 Series complies with IEC 60079. The 51 Series explosion-proof analyzers infrared allow for the measurement of CO, CO2, CH4 and other organic gases. The TCA-51 uses a thermal conductivity detector for H2 measurements and the MPA-51 and PMA-51 models integrate magneto-pneumatic and paramagnetic detectors for O2 measurements.
-
product
Flash Diffusivity Analyzers
The Light Flash technique provides information on a material’s ability to store and transfer heat through measurements of thermal diffusivity, thermal conductivity, and specific heat capacity. Thorough understanding of these properties is critical for any process or material which experiences a large or fast temperature gradient, or for which the tolerance for temperature change is exacting. Accurate values of these properties are essential for modeling and managing heat, whether the component of interest is called on to insulate, conduct, or simply withstand temperature changes. Information about these properties is routinely used in heat transfer models of all complexities. Heat transfer property measurements also reflect important information about material composition, purity and structure, as well as secondary performance characteristics such as tolerance to thermal shock.
-
product
GSR Logger Sensor
NUL-217
The Galvanic Skin Response (GSR) logger sensor measures the conductivity of our skin, especially of our fingers. The conductivity of our skin changes according to unconscious emotion effects such as sudden noise, smell, touch, pain or view.
-
product
Seawater Refractometer
AQUAR-H5O
The Palm Abbe AQUAR Digital Seawater Refractometer is a professional refractometer for testing seawater, salt water, and brackish ocean water for oceanography, aquaculture, aquariums, desalination plants, and ocean research. The model AQUAR-H5O measures seawater salinity in Practical Salinity Units (PSU), Sigma-t Density, Specific Gravity, Conductivity, and Chlorinity.
-
product
Salinity Concentration Pocket Water Meter
LAQUAtwin Salt-11
The only pocket meter that directly measures conductivity in 0.12ml sample and converts it into salinity or salt concentration. No need for a beaker to calibrate the meter or measure a sample. Just place few drops of the standard or sample onto the sensor. This procedure saves you time and prevents wasting your precious sample.
-
product
Liquid Thermal Conductivity Instruments
THW-L1
The Transient Hot Wire (THW-L1) Liquid Thermal Conductivity Meter is an advanced measurement system for direct determination of the thermal conductivity, thermal diffusivity, and specific heat instrument for measurement of liquids and pastes in accordance with ASTM D7896-19. The THW-L1 was designed with speed and operational simplicity in mind. With a single measurement of 1 second in duration, small volumes of liquids and pastes can be accurately and precisely measured for thermal conductivity, thermal diffusivity, and specific heat. The THW-L1 utilizes a non-stationary measurement approach and rapid test times to limit convective effects for samples with a wide range of viscosities. The THW sensor consists of a thin heating wire 40 mm in length and is completely inserted into the sample to be tested.
-
product
Water Monitoring Modules
Unidata offers a wide range of instruments to suit the measurement of conductivity, evaporation, water depth and temperature. In addition to those water instruments, Unidata also offers Starflow QSD ultrasonic Doppler velocity and depth SDI-12 Instrument.
-
product
Benchtop Conductivity Meter
LAQUA EC2000
Water quality analysis is repeatedly performed in laboratories on a daily basis. Our compact and powerful benchtop model was developed to provide simplicity with excellent on-site usability.
-
product
Water Quality Products
When you need to perform critical water testing, look to us for an extensive selection of electrochemical meters, controllers, probes, electrodes, test kits, buffers, and standards. Our field and laboratory instrumentation include water analysis instruments for dissolved oxygen, temperature, pH, conductivity, salinity, and turbidity.
-
product
Reverse Osmosis Meters For Measuring Total Dissolved Solids
RO Meters™
The choice of professionals for years, this compact instrument has been designed specifically to demonstrate and test Point of Use (POU) reverse osmosis or distillation systems. By measuring electrical conductivity, it will quickly determine the parts per million/Total Dissolved Solids (ppm/TDS) of any drinking water.
-
product
Gas Analysis
Accurate measurement of gases and their concentrations is critical in many applications, and often poses a major challenge. Sensors' experience with different measurement principles, including NDIR, NDUV, and thermal conductivity, along with the ability to provide special combinations of these techniques within our products, enables us to tackle these challenges. In addition, our experience goes into every detail of our gas analyzers, ensuring reliable results, even under harsh conditions. Our skilled team of experts is happy to assist you in finding the optimized solution for your measurement requirements, with either off-the-shelf components or a customized solution.
-
product
Total Organic Carbon Monitor
HT-110
The continuous online TOC-Analyzer HT-110 is suitable for the measurement ot total organic carbons in Purified Water (PW), Water For Injection (WFI) and Highly Purified Water (HPW). The unit is operating according to USP 643. It is applicable for pharmaceutical and/or semiconductor manufacturing. The measuring principle is based on UV-Oxidation and measurement of the difference in conductivity. TOC concentration measurement (TOC concentration 500 ppbC or lower) is necessary to perform quality control according to GMP (Good Manufacturing Practice).
-
product
Thermal Conductivity Analyzer
Model 2000B
Teledyne Analytical Instruments
The Series 2000 represents a complete line of Thermal Conductivity Detector (TCD) based analyzers which can be applied in a wide range of applications and industries. By using field proven filament-based and semiconductor based TC detectors, Teledyne is able to continuously monitor hydrogen and a variety of other gases of interest in either binary or multi-component sample gas streams.
-
product
Micro and Milliohmmeter
AD-7010
AD-7010 instrument is designed to measure, with high accuracy, the resistance of conductive elements power equipment: motor windings, transformer windings, conductor rails, inspecting the electrical conductivity of bolted joints, crimped, welded, the contacts of switches and relays.
-
product
Contact Level Sensors
Contact level devices come in contact with the tank media and are used for point or cocntinious level measurement. Types include Float, Optical, RF Capacitence, Conductivity, Ultrasonic, Tuning Fork.
-
product
Sputter Coater & Freeze Fracture Solutions
To obtain high-quality images of samples with scanning (SEM) or transmission electron microscopy (TEM), your samples need to be conductive to avoid charging. If a sample does not have a high enough conductivity, then you can quickly cover it with a conductive layer using the method of sputter coating. Also, a carbon or e-beam evaporator coating can be used. Such coatings protect the sample, allow enhancing of the EM image contrast, or can act as a TEM-grid support film for small scale samples.
-
product
Heat Flow Meter
Thermal conductivity is a measurement of a materials ability to conduct heat and can be critical for evaluating energy efficiency and thermal performance of materials. The HFM-100 Heat Flow Meter is designed as an easy-to-use method for the measurement of thermal conductivity and thermal resistance of insulation products, construction materials, packaging, and assemblies. Available at an exceptional value, the Thermtest HFM has been engineered for industry-leading performance by combining the highest accuracy, repeatability, and widest temperature range possible, and follows international standards: ASTM C518, ISO 8301, and EN 12667.
-
product
Thermitest
THW-L2
Designed with speed and operational simplicity in mind, the Transient Hot Wire (THW-L2) Liquid Thermal Conductivity Meter is an advanced measurement system for direct determination of the thermal conductivity of liquids and pastes in accordance with ASTM D7896-19. In less than 2 seconds, a single measurement of small volumes of liquids and pastes can be accurately and precisely measured for thermal conductivity. Using a non-stationary measurement approach, the THW-L2 uses rapid test times to limit convective effects for samples with a wide range of viscosities. The THW sensor consists of a 60 mm heating wire that is fully inserted into an isothermal sample. A constant current source (q) is used to heat the sensor wire and the temperature rise is recorded by monitoring the change in electrical resistance of the wire. The slope (m) is determined from the plot of temperature rise vs. logarithm of time and is used in the calculation of thermal conductivity (λ). Liquid samples of high thermal conductivity will have a lower slope, while liquid samples with low thermal conductivity will have a higher slope.