Harmonic
Sinusoidal component of a perodic wave or for a sine wave, it is an integral multiple frequency of the wave.
-
Product
PXI-2597, 26.5 GHz, 50 Ω, 6x1 (SP6T) Terminated PXI RF Multiplexer Switch Module
778572-97
RF Multiplexer
26.5 GHz, 50 Ω, 6x1 (SP6T) Terminated PXI RF Multiplexer Switch Module—The PXI‑2597 is ideal for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules. The internal termination of the PXI‑2597 helps prevent high-power reflections that arise from open channels on the module. You can use the PXI‑2597 onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
Product
Panel Mounted Power Quality and Energy Monitor.
PM7503
-
The PM7503 Power Quality and Energy Monitor is a panel mounted variant of our top of the range PM7000 Power Quality Analyser. As with the PM7000 and P7000FLM, as well as recording all other important power quality parameters, the PM7503 with the optional Interharmonics upgrade is able to record 100 Voltage or Current harmonics on all 4 inputs at the same time.
-
Product
Phasor Meter
633
-
Red Phase Instruments Australia Pty Ltd.
This instrument is designed to demonstrate the properties of phasors and real/imaginary number notation for electrical engineering students. This instrument gives the phase displacement and magnitude of the parameter under investigation. The unit has filters to eliminate harmonic distortion affecting phase angle measurement.
-
Product
AC Power Source
LSP-500VAR
-
• AC-DC-AC frequency conversion technology, Controlled & tested by 16 bits MCU • Protection for over hot, thundering voltage and current • Total voltage distortion: ≤0.3%; Voltage stability: ≤0.05%/30min • Load adjust rate: ≤0.05%; Frequency stability: ≤0.01%/30min • Output voltage range: AC 0.0~300.0V, Output Frequency Range: 45~70Hz, 100Hz, 200Hz and 400Hz • It is pure sine wave AC power source with low harmonic and high accuracy • Input Power: 220V and 50/60Hz (110V can be option) • Communicate with PC via software, the Voltage & Current set by the software and Power Output can be remote controlled.
-
Product
Performance AC Sources/Analyzers
6800 Series
-
Accurately analyze your AC power environment with integrated waveform generation and harmonic capabilitiesIncrease your productivity with extensive built-in power measurement capabilitiesLower your cost of ownership with global support & the longest standard warranty in the industry
-
Product
InGaAs PIN Photodiodes
-
Discovery Semiconductors, Inc.
High Optical Power HandlingLow Group DelayLow Harmonic DistortionLowest PDL (typical 0.05 dB)Useable spectral wavelength range of 800-1650 nmTelcom, Military and Space Qualified
-
Product
Portable Test System
MT786
-
Actual value, vector, curve displayCurrent and voltage generationerror measurementMeasurement of harmonics up to the 40th
-
Product
Electrical Products
-
We offer a broad range of electrical testers, electrical analyzers, and electronic safety test equipment to help you measure AC and DC current and voltage, resistance, frequency, capacitance, harmonics, power energy, and more. Plus get the power supplies to keep your equipment running and the enclosures to protect your electrical and electronic products.
-
Product
PXI-2797, 40 GHz, 50 Ω, 6x1 (SP6T) Terminated PXI RF Multiplexer Switch Module
782357-01
RF Multiplexer
40 GHz, 50 Ω, 6x1 (SP6T) Terminated PXI RF Multiplexer Switch Module—The PXI‑2797 offers a high-density, terminated multiplexer with dual 6x1 multiplexer banks in the same module. The internal termination of the PXI‑2797 helps prevent high-power reflections that arise from open channels on the module. It is ideal for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules.
-
Product
Voltage Controlled Oscillators
-
a High Reliability Low Noise Voltage Controlled Oscillator (VCO) which covers a 10 MHz to 20 MHzfrequency band with a voltage tuning range from 0V to 20V. This design features exceptional phase noise performance of -120dBc/Hz @ 10 kHz offset. Supply Voltage is +15V with a generated output power level of +10 dBm and 2nd harmonic output of-11 dBc typical. The assembly is RoHs compliant and available in a compact 0.5 inch SMT package with an industry standardmounting footprint. The bottom surface is copper clad with 2-5 micro inches of immersion Gold over 150 - 250 micro inchesof Electro less Nickel which makes it resistant to oxidation for ease of soldering. The VCO operates over a temperature rangeof -40°C to +85°C and is designed to meet a variety of MIL-STD-202 test conditions including Humidity, Shock, and Vibration.
-
Product
Power Meters
Power Meter
Teledyne Test Tools range of digital power meters are for single-phase (1P/2W) AC power measurements with a test Bandwidth ranging from DC, 0.1 Hz to 100 kHz. The T3PM1006 model features a 4” TFT LCD screen with a five-digit measurement display. It offers 19 power measurement parameters to choose from, integration measurement function, front/rear panel input terminals, and various communication interfaces to help users to make convenient and accurate power measurement. The T3PM1100 model offers DC, 0.1 Hz ~ 100 kHz test bandwidth, 16 bits ADC, and 300 kHz sampling rate. It features a 5” TFT LCD screen with a five-digit measurement display. It also has options to display waveform (voltage/current/power), the integration measurement function, harmonic measurement and analysis of each order (meeting the IEC 61000-4-7 harmonics measurement requirements at 50/60 Hz), external sensor input terminals, and various communication interfaces to help users to make convenient and accurate power measurements.
-
Product
Automated Tuners / Impedance Tuners / Load Pull Tuners
-
MT97x, MT98x and XT98x series automated tuners (also known as automated impedance tuners and automated load pull tuners) are precision instruments that are optimized for a broad class of in-fixture and on-wafer applications, and may be used in any automated or manual application requiring the ability to match the impedance of a microwave circuit element or to establish specific impedances at a terminal interface. The tuner design is based on the slide screw concept using the inherently broadband slab-line transmission structure. Each unit has two non-contacting probes deliver high VSWR with superb accuracy and reliability over a wide frequency range. These probes can be fully retracted leaving a low-loss, well-matched transmission line, which is a significant benefit in power related applications where two-port tuners capable of handling large amounts of power are required. As integral components of Maury Device Characterization Solutions, these PC-based tuners are controlled using Maury's family of Device Characterization Software tools, including MT930 IVCAD, MT993 ATS and the DLL-based measurement automation environment. Maury Microwave automed impedance tuners are ideal for load pull, harmonic load pull, active load pull, hybrid active load pull, noise figure, noise parameters and all automated tuner applications.
-
Product
AC Power Source
SPS-50
-
Kongter Test & Measurement Co., Limited
SPS-50 standard power source is applied for various tests of analog and digital AC voltage meter and current meter, single/three phase active and reactive power meter, phase angle meter, single/three phase power factor meter, frequency meter, and synchronous-meter, single/three phase active and reactive power meter. It also output 2nd ~63rd harmonics.
-
Product
Phase Noise Measurement Up To 125 GHz
S930321B
-
S930321B enables phase noise measurements using a PNA or PNA-X vector network analyzer. Simplify your measurement workflow by measuring phase noise on the same connection as your network analysis measurement of 2-port active devices up to 125 GHz, without needing to connect a spectrum analyzer or harmonic mixer.
-
Product
IEC Standard Burden Sets (Current)
IEC Burden Sets
-
Testing and calibrating current transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. These burden sets have been carefully designed to meet these requirements. They also provide the standard burdens required for the testing of current transformers for metering service, and for the testing (within the current rating provided by the sets) of current transformers for relaying applications, all as called for by IEC (International Electrotechnical Commission) Publication 185: 1987.
-
Product
Three-Phase AC Power Sources
AC6900 Series
-
Keysight’s AC6900 Series AC power sources provide a complete AC and DC power solution by combining the capabilities of a multimeter, harmonic analyzer, and power analyzer in one instrument. You can easily produce DC power, either alone or as a DC offset to an AC waveform, in a compact form factor.
-
Product
SHG Spectrometer
-
Second harmonic generation (SHG) is an effective technique for surface probing. By SHG, monolayer adsorbtion can be detected. With different input/output beam polarizations SHG can yield information on the average orientation of molecular adsorbates.
-
Product
Digital Power Meter, 30A
66205
-
Chroma Systems Solutions, Inc.
Voltage Ranges:15/30/60/150/300/600 Vrms1200Vrms (optional)Current Ranges : 0.005/0.02/0.05/0.2/0.3/0.5/2/5/20/30 ArmsFrequency Range : DC, 15Hz~10kHzEmbedded high speed DSP, 16 bitsAnalog/Digital converters withmax samipling rate up to 250kHzCapable of meeting the IEC 61000-4-7harmonics measurement requirementsSmart Range function provides seamlesspower integration measurement underauto range modeSupports external shunt and CT forhigher current applications5 mA minimum current range &0.1mW power resolutionMeets ENERGY STAR /EN 50564/IEC 62301/ErP requirementsUser-define criteria providesautomatic PASS/FAIL indicationsTHD and user-specify order distortionmeasurementInrush current and energy measurementsVoltage/ Current harmonics measurementsup to 100 ordersUSB (Host) interface provides data loggingfunctionalitySupport GPIB, USB, RS232, LAN (option)interface
-
Product
Three-Path Diode
NRPxxS/SN/SN-V
-
The R&S®NRPxxS/SN power sensors use three separate diode paths, each operated in the optimum detector range. As a result, the average power can be determined with high accuracy independent of the modulation type. Measurement results are hardly affected by interfering signals or harmonics.
-
Product
Harmonic Trap Inductors
-
Osborne designs harmonic trap inductors to work in conjunction with capacitors in power systems to prevent specific line-frequency harmonics from flowing back to the power source (point of common connection). This power quality design approach prevents harmonic currents from flowing to the main facility power system and/or to the utility power system. The Osborne system also reduces unnecessary power losses and power-system pollution.
-
Product
Multifunction Meter for Electrical Installations
AMPI-530
-
Measurement of short-circuit loop ; Testing of differential, general and selective protections for differential current ; Measurement of insulation resistance ; Up to 10GΩ ; Voltages: 50 V, 100 V, 250 V, 500 V, 1000 V ; Measurement of earth resistance ; Bi-directional continuity test on PE cables, phase sequence ; Measurement and recording of voltage, frequency, alternating current, cosϕ, power, harmonics and THD
-
Product
Ultra-Low Distortion Function Generator
DS360
-
Stanford Research Systems, Inc.
The performance of a low distortion analog source and the precision of direct digital synthesis (DDS) is combined in the DS360. With less than 0.001 % total harmonic distortion (THD), 25 ppm frequency accuracy, and a broad range of features including sweeps and bursts, the DS360 is the ideal source for audio frequency applications.
-
Product
Portable Test System
MT781
-
Actual value, vector, curve displayCurrent and voltage generationerror measurementMeasurement of harmonics up to the 40th
-
Product
Harmonic Mitigation Transformer
-
A specialized three-phase transformer designed to reduce harmonic distortion and voltage distortion caused by non-linear loads (e.g., computers, VFDs) in electrical distribution systems.
-
Product
Microprocessor Multifunction TRMS Power Meter + Harmonics Analyzer
8100 C
-
Kusam Electrical Industries Limited
INPUT :• Input Voltage Range :Voltage: 55 ~ 300V AC, or 300 ~ 600V AC, 45 ~ 65Hz.P.T. Ratio Programmable upto 9999 / KV.• Input Voltage Over Range :Voltage : 200 % Continuous, 300 % of rating for 10 sec.• Input Current Range :Current : 110 % of rating. 0-1A or 0 - 5AC.T. Ratio programmable upto 9999 / 5A.Input Current Over Range:Current : 400 % Continuous, 2000 % of rating for 10 Sec.• Input Frequency : 45 Hz ~ 70 Hz.• Input Burden :Voltage 0.25 VA / Unit, Current 0.25VA / Unit, at 50 / 60HzOUTPUTDC Current: 0 20 m A DCLoad resistance drive: output drive 10 V DC maximum.DC Voltage: 0 -10 V DCLoad resistance drive: output drive 5mA maximumOutput Protection: No damage even if output is Open orShort Circuit.Output Response Time : £ 1 Sec.Digital Output : RS485 Output, Isolate Type withMODBUS RTU mode., 4800, 9600,19200Baud Rate, User Selectable.
-
Product
ANSI Standard Burden Sets
Voltage and Current
-
Testing and calibrating instrument transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. The burden sets described below have been carefully designed to meet these requirements.
-
Product
Phase Noise Measurement Up To 70 GHz
S930317B
-
S930317B enables phase noise measurements using a PNA or PNA-X vector network analyzer. Simplify your measurement workflow by measuring phase noise on the same connection as your network analysis measurement of 2-port active devices up to 70 GHz, without needing to connect a spectrum analyzer or harmonic mixer.
-
Product
Harmonic Filter Resistors
-
The widespread use of nonlinear loads such as power electronics based equipment and electric arc & ladle melt furnaces all around the world hinder the quality of electric power. One of the most important parameters for defining the power quality is harmonic distortion.
-
Product
Power Quality Measurement & Digital Fault Recording
-
In view of the growing number of factors with a disturbing influence on power systems and the ever increasing sensitivity of devices and installations on the consumer side, simple monitoring criteria such as undervoltage or overcurrent are no longer adequate. Reliable registration of all the relevant processes within the electrical power system calls for constant observation of a wide variety of derived parameters, such as individual harmonic content, system unbalance and interharmonics, and the swift identification of even slight deviations from the norm.
-
Product
PC Controlled Bench Top Power Analyzer
PA2100
-
The PA2100 is a PC controlled bench top power analyzer, allowing several electrical power measurements to be taken simultaneously during testing - from just one set of input connections. The PA2100's power measurement ability is a must in research and development, manufacturing and required for certification and traceability of manufactured goods. In addition to power measurements, apparent power (VA), harmonics, voltage, current, power factor can all be viewed and stored with ease. The PA2100 wattmeter simply connects between the ac supply and the load, various current transformer options allow measurement with any size of current from 10mA to 10000A. Typical watt meter applications include appliance testing; microwave ovens, electric stoves, heating, air conditioning, TVs, monitors, computers, electronic lighting, fans and motor controllers. Powertek wattmeters are equipped with 4mm/banana safety terminals along with optional "breakout" boxes and clamp current probes for fast and safe measurement.





























