product
Voltage References
Renesas' wide selection of voltage reference (Vref) circuits offer accurate and stable reference voltages unaffected by external influences such as variation in temperature, input voltage and time.
-
product
OTDR Training & Calibration Solution
In addition to network simulation applications, the Fiber Lab 800HE from M2 Optics is a professional optical fiber platform that enables technicians to practice using an OTDR to find splices, faults, or bad connections in a length of optical fiber. In addition to training, it can also be used by equipment servicing teams to calibrate OTDRs with fiber that includes pre-determined events at known points.
-
product
Multifunction Calibrators
Many of the calibrators we offer are multifunctional calibrators, that is because then you don’t need to carry so many devices and also don’t need to recalibrate several devices. For us the “multifunctional” means a calibrator that can measure and generate electrical, temperature and pressure signals.
-
product
AC Power Calibrator
LS3300
The LS3300 is an AC signal generator capable of outputting both current and voltage simultaneously, thus allowing it to calibrate power meters. Providing output ranges of 10mV-1250V, and 0.3 mA to 62.5 A, and upto 78.125 kW, the unit is capable of calibrating up to 0.15 % Class Power meters. New features on the LS3300 include a high definition LCD display, a vector diagram, and the ability to synchronize up to three units to emulate anything from single phase two wire to three phase four wire systems.
-
product
ECU Calibration
Designing an Electronic Control Unit (ECU) is only the beginning. The features in ECUs, such as Powertrain Control Units, are quickly becoming more complex and offering more features. Thousands of variables are now provided for the engineer to modify during the in-vehicle calibration phase, and fine tuning them is as complicated as it is critical. Calibration tools significantly impact the efficiency and effectiveness of the ECU development process. These tools are typically comprised of PC-based software to perform the adjustment of the variables and an ECU hardware interface to provide the connection of the software to the controller. Teams must be able to measure and time-align relationships of inputs and outputs and make real-time modifications.
-
product
Calibrators
Portable and user friendly calibrator, ideal for checking sound level meters and dosimeters on the measurement site, or in the laboratory.
-
product
Xytronic Three-Phase Reference Standard +/- 0.04%, +/- 0.02%, +/- 0.01%
RADIAN RX-30, RX-31 and RX-33
Radian Research is committed to providing our customers with leading innovative and technologically superior products, while maintaining metrology capability in power and energy measurement that is surpassed by none. Our engineers drew on the expertise and knowledge we acquired for our industry-leading legacy RM (Metronic) and RD (Dytronic) reference standards to develop the RX (Xytronic), the ultimate in power and energy measurement technology perfection.
-
product
Reference Clock T Connector
780540-01
The SMA-SMA-SMA T Connector, sometimes referred to as the Reference Clock T Connector, connects RF wireless test devices and PXI modular instruments to other accessories. It is a 50 ohm … impedance connector that measures 0 GHz to 10 GHz.
-
product
Calibration Services
We offer a full range of calibration services and repairs. Our Indianapolis calibration laboratory is accredited in accordance with the recognized international standard ISO/IEC 17025 (2017) and meets the requirements of ANSI/NCSL Z540-1994-1. Alternatively, our network analyzers and calibration kits can be calibrated by any ISO17025-accredited and Z540-1 compliant calibration lab worldwide.
-
product
Low Phase Noise Reference Source
96270A
The 96270A RF Reference Source is the simplest, most accurate and cost-effective single instrument for calibrating spectrum analyzers and RF power sensors and more, up to 27 GHz.
-
product
Hipot Current Calibration Load Resistors
HPRS-HIPOT-LOAD
The IET HPRS-Hipot-Load is an excellent replacement for the Fluke 5320A-Load Hipot current calibration load resistors. The IET high power resistive load can be used with the Fluke 5320A Multifunction Electrical Tester Calibrator or standalone. It provides a high power and high voltage load to various hipot tester to create the leakage current needed to calibrate various manufactures hipot testers.
-
product
Calibration Lead Precision Resistor - Single
40-975-009-SL1
The cable assembly is specifically designed to connect to the 9-Pin D-Type calibration port located on the front panel of Pickering Interfaces Module Part Numbers 40-260, 40-261, 40-262, 40-263 and 40-265.
-
product
Arrester Discharge Counter Calibrator
HTFZ-III / 451
Wuhan Huatian Electric Power Automation Co., Ltd.
Test whether the arrester of each type of arrester is operating normally.
-
product
NIST Calibration for D600A-AT.
D600A-AT-CCNIST
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
product
Hydraulic Calibration for Load Cell
HLCS-10000
Jinan Testing Equipment IE Corporation
The Hydraulic Calibration System is specially designed for the calibration of load cells with higher capacity. The Calibration for Load Cell can calibrate the load cell within +/-1%.
-
product
Phasor Measurement Unit Calibration System
6135A/PMUCAL
The 6135A/PMUCAL system is the only fully automated and traceable PMU calibration system available today. It fully complies to the IEEE C37.118.1™-2011 and section 7 of IEEE C37.242:2013 standards for PMU operation and verification.
-
product
Process Calibrators
We offer process calibrators that are designed for the process industry applications and to be used in the demanding conditions in process industry.
-
product
Calibration Kit
N912
*N912 Calibration Kit, * Frequency Range: up to 9 GHz, * Impedance: 50 Ohm, * Connector Type: N-type.
-
product
Temperature Calibration Software v5.1
MET/TEMP II
MET/TEMP II software allows you to easily automate the calibration of a wide range of temperature sensors. It provides a comprehensive temperature calibration solution that allows you to test large quantities of sensors, calculate characterization coefficients, and print calibration reports. You can standardize comparison or fixed point calibrations and use multiple temperature sources or references in one test.
-
product
Multifunction Calibrators
These field and bench calibrators source, simulate, and measure pressure, temperature, and electrical signals with exceptional precision. They can automate calibration procedures, store data, and even calibrate and troubleshoot HART-compatible devices. Our bench calibrator can even be used to calibrate our field calibrators. Also find here 5.5- and 6.5-digit bench multimeters for to assist with a variety of general test and calibration applications.
-
product
Calibration services
Transcat Calibration Services offers the widest scope of ISO/IEC 17025 accreditation in the industries we serve. In fact, we are accredited for over 99% of our capabilities, and more than 95% of the calibrations we perform are accredited.
-
product
Power and Energy Automated Calibration System
RS-933
The RS-933 Syntron Power and Energy Automated Calibration System calibrates a range of test equipment including; Energy Reference Standards, Digital Multimeters, Phase meters, Energy meters, Power meters, Revenue meters, Amp meters, Panel meters & Power Quality meters.
-
product
Temperature Calibrators
We offer temperature calibrators in different shapes. We offer temperature dry blocks that can generate an accurate temperature, for example for temperature sensor calibration. We also offer electrical temperature calibrators that can measure and simulate various temperature sensors (RTDs and thermocouples). We also offer high-accuracy reference temperature probes.
-
product
Programmable Voltage Reference Plug-In
ProDAQ 3202
The ProDAQ 3202 voltage reference card is used in the ProDAQ 3180 ultra-performance motherboards and LXI function card carriers. The ProDAQ 3202 voltage reference card is plugged directly onto the motherboard or carrier and can distribute the reference voltage to all ProDAQ function cards via two signal lines. This allows the distribution as a differential signal to overcome possible noise pick-up.
-
product
Acceleration Pickup Calibrator
VX-1100A
VX-1100 is for a piezoelectric type accelerometer which is widely used for measuring vibration. This compact calibrator is effective for checking operation(sensitivity) sensors before measurement to acquire accurate data.Built-in sensor amplifier and display in one unit allows direct reading of the sensitivity. This calibrator excites the sensor at a frequency of 159 Hz and acceleration of 10 m/s2 rms, and the sensor outputs can be used as calibration signals for a vibration measuring system.
-
product
Resistor Calibration Boxes
RCB-3
Standard Electric Works Co., Ltd
● The RCB-3 is used to verify and proof any High Voltage Insulation Testers. It can be utilized to calibrate all High Voltage Insulation Testers very accurately Analogs or Digitals.● Some institutions and large industries requested their own calibrator too, therefore, SEW started manufacturing the RCB for special customers.
-
product
Multifunction Calibrator 15 ppm Basic Accuracy
MC142
Multifunction calibrator MC142 is a precision voltage, current and power calibration source serving as a measurement standard in calibration laboratories and production lines; where verification of electrical measurement equipment & sensors is required. It can be used for calibration and adjustment of meters measuring voltage, current, power, resistance, capacitance and frequency. Internal harmonic and non-harmonic signals make it possible to test electrical performance of meters using signals with various crest factors. Frequency modes enable selection of frequency, amplitude and duty cycle of the output signal. These are suitable for basic calibration of digital and analog oscilloscopes along with transient recorders. The calibrator is equipped to measure temperature with TC and RTD temperature sensors. Its built-in multimeter can be used independently or simultaneously with the calibrator output. Testing of transducers of various types, regulators and sensors can be performed, without the necessity to use any other measuring instrument.
-
product
FOCL Reference Signal Modem
VCH-607
FOCL reference signal modem VCH-607 is designed to receive and transmit electrical signals with a nominal frequency of 100 MHz through a fiber-optic system and generate electrical signals with a nominal frequency of 5 and 10 MHz, coherent with the input signal. Reception and transmission through the FOCL is provided using a pair of modems: one is configured as a Transmitter and is installed at the end of the FOCL where the signal source is located, the second is configured as a Receiver and is installed at the opposite end of the FOCL.
-
product
Calibrated, Integral Isolator Noise Sources
Calibrated, Integral Isolator Noise Sources by Pasternack
-
product
Calibration & Demag.
Model 990A/990C
The Model 990 Series Magnetreaters® are highly accurate, pulse type, ringing demagnetizers (also called treaters) for the controlled stabilization of permanent magnets and permanent magnet assemblies. Regardless of line voltage stability, they provide a controlled output through continuous pulse amplitude regulation. Treating voltage is variable from 0 to 600 VDC. Additional energy can be added to the Model 990 Series by interconnecting a Model 992 Energy Booster. The energy level is increased from 18 to 36 watt-seconds. With this option, treating coils will produce higher demagnetizing fields and lower ringing frequencies, which can provide greater field penetration in some applications.