Frequency Weighting
-
product
120 GHz Frequency Extender, Pulsed DC Bias
N5295AX52
The N5295AX52 is a compact and broadband frequency extender with built-in pulsed bias-tee and provides 10 MHz to 120 GHz single-sweep measurements with N5292A test set controller systemized with a PNA/PNA-X B vector network analyzer.
-
product
110 GHz Frequency Extender
N5293AX51
The N5293AX51 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03B-006
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Dielectric VTE Rating (k VAC): 1Nominal Impedance (Ohms): 50Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
product
110 GHz Frequency Extender
N5293AX03
The N5293AX03 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
product
110 GHz Frequency Extender, Pulsed DC Bias
N5293AX02
The N5293AX02 is a compact and broadband frequency extender with built-in pulsed bias-tee and provides 10 MHz to 110 GHz single-sweep measurements with N5292A test set controller systemized with a PNA/PNA-X B vector network analyzer.
-
product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L-QG
Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 0.80Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75R
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03G-003
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50H-S
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
product
Active Differential Probe, 100 kHz to 12 GHz
U1818B
The Keysight U1818B 100 kHz to 12 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818B allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.
-
product
RF High Frequency Probes
*Low impedance*High bandwidth up to 20 GHz*Repeatable measurements*Coaxial design*Interchangeable center conductor
-
product
Active Differential Probe, 100 kHz to 7 GHz
U1818A
The Keysight U1818A 100 kHz to 7 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818A allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.
-
product
110 GHz Frequency Extender
N5293AX53
The N5293AX53 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
product
120 GHz Frequency Extender
N5295AX53
The N5295AX53 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
product
Frequency Meter, 3.7 to 12.5 GHz
537A
The Keysight 537A direct-reading frequency meter measures frequencies from 3.7 to 12.5 GHz quickly and accurately. Its long scale length and numerous calibration marks provide high resolution. This is particularly useful when measuring frequency differences or small frequency changes. Frequency is read directly in GHz so interpolation or charts are not required.
-
product
Molecular Weight Analyzers
Brookhaven Instruments Corporation
Molecular weight and size are two key properties of all macromolecules including biologically important and synthetic polymers. Performance and processability are directly related to these parameters. Light scattering is capable of absolute measurements in either batch or flow mode. For distribution information, couple a GPC/SEC instrument to a light scattering detector.
-
product
Calibration Hangers And Weights
Calibrated Dead Weight are the official means by which torque analyzers and torque sensors are calibrated and are traced to National or International Standards, such as N.I.S.T, ISO and others. Many industries like as medical, aerospace, nuclear and others continuously calibrate their measuring equipment to comply with government regulations. For companies that prefer to have calibration capabilities in-house when their calibration requirements become extensive, they need calibration equipment.
-
product
Weight Drop Controller
WDC
The WDC unit consists of the following: *Weight Drop Relay Control System *Radio Trigger Module (RTM) *Remote Control Box *Radio*Hammer Switch The WDC provides following features: *Automatic cycling with user entered number of hits*Time Delay Display (Time from fire command to hit)*GPS interface for position and timing*Remote Control Box
-
product
NI-9326, 6-Channel, 150 V, 128 kHz C Series Frequency Input Module
786999-02
6-Channel, 150 V, 128 kHz C Series Frequency Input Module - The NI-9326 is a channel-to-channel isolated frequency input module for CompactDAQ and CompactRIO systems. This module includes six differential input channels with a 0 Vrms to 150 Vrms input range. The NI-9326 also features configurable thresholds for connection to a variety of variable reluctance sensors, single channel encoders, and hall-effect sensors. You can use the included embedded counters to perform frequency measurements or edge-counting for tracking total counts on a periodic signal. Additionally, the NI-9326 supports configurable Butterworth filters to help you perform low-noise frequency measurements.
-
product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40A-024
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 225 (5.72) including travel of probes
-
product
Bidirectional Weight Indicator
480
Large 0.8 in LED 6-digit Display• 100,000 displayed graduations• 523,000 internal counts• Powers up to 10 Load Cells• Tension/Compression operation• NEMA 4X stainless steel enclosure• Measurement Rate up to 40Hz• Selectable filter settings• 0.1uV/graduation signal sensitivity
-
product
Drop Weight Impact Testing Machine
DWTT Series
Jinan Testing Equipment IE Corporation
DWTT Drop Weight Impact Testing System is suitable for drop weight tear test of various kinds of ferrite, especially for the test of DWTT for pipeline steel as ASTM-E 436, API-RP 5L3, ASTM-E 208 and DIN EN 10274. DWTT has integrated mechanical, electrical, and automatic control technology, and achieved full automation of feeding, hammer lifting impact, and fracture specimen collection. The load frame has a four-column design, features in stable supporting structure, rigid, dual sliding rails. The Drop Weight Drop Weight Tester is equipped with positioning mechanism, anti-dumping mechanism, safety mechanism, hydraulic buffer devices and security guard net. The impact energy is determined by the lifting height and configuration of different net weights. DWTT Drop Weight Impact Testing System is the essential quality control equipment for pipeline manufacturers, steel mills, iron and steel enterprises, and is also widely used for research institutes.1. Buffer device is equipped to avoid the second impact and absorb the residual energy after breaking the specimen so as to prevent the weigher and anvil from destroying. The installation of safety mechanism, buffer device, and security guard net will effectively secure the testing machine and its operation to extend its life.2. Configuration of the specimen-feeding system, anti-second impact device, and specimen centering mechanism will guarantee a quick, accurate and reliable test.
-
product
Densigrader: Dynamic Weight Sorter
The Densigrader: Dynamic Weight Sorter is made for on-line mass/density measurements and sorting of green lumber prior to drying. The accurate mass and optional volumetric measurements provide an increase in grade recovery and kiln productivity. Its small footprint fits easily into most transverse, lugged transfer chains. System employs either RS232 or TCP/IP protocols to hand off data to sorting PLC.
-
product
120 GHz Frequency Extender, Pulsed DC Bias
N5295AX02
The N5295AX02 is a compact and broadband frequency extender with built-in pulsed bias-tee and provides 10 MHz to 120 GHz single-sweep measurements with N5292A test set controller systemized with a PNA/PNA-X B vector network analyzer.
-
product
Frequency Standards
Precision Test manufacturers a complete range of frequency standards. This includes rubidium and OXCO models either free running or controlled by an external reference (GPS, GLONASS, Galileo, 1pps, 5 MHz, 10 MHz, IRIG-B etc). Output frequencies typically 1 MHz, 5 MHz, 10 MHz, 10.23 MHz, 13 MHz, 100 MHz or bespoke frequency.
-
product
Weights
Vetek only sells precision class M1 weights on our webshop. In most cases these act as ideal control weights. If you require weights with a certificate for first time verification, please contact us.





























