Gas Leak Detection
See Also: Gas Leak Detectors
-
product
Personal Safety Gas Monitors
Teledyne Gas & Flame Detection
Want to protect your staff with high-end portable gas detectors? Discover Teledyne Gas and Flame Detection gas detection solutions.
-
product
Smoke Detection Sensor - CE Approved
ENVIROMUX-SDS-CE
For warning of smoke. Photoelectric smoke detector. Smoke sensitivity: 0.08-0.14 dB/m. Built-in 135° F (57° C) thermal heat sensor. Includes mounting hardware. Connect to RJ45 or digital input sensor ports. Supports CAT5/5e/6 UTP or STP cables. Screw terminal. To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal. Operating temperature: 14 to 122°F (-10 to 50°C). Maximum cable length: 1,000 ft (305 m). Powered by ENVIROMUX-2D/5D/16D. Regulatory approvals: CE, RoHS.
-
product
Gas Leakage Detector
*Sense leakage of combustible gases such as butane, propane, acetylene and - methane (natural gas)
-
product
Gas Chromatographs
Teledyne Analytical Instruments
Gas Chromatographs by Teledyne Analytical Instruments
-
product
Infrared Gas Detector
iTrans2
Teledyne Gas & Flame Detection
The iTrans2 infrared gas detector employs an intelligent electronics platform to provide one or two points of detection from a single head for maximum flexibility, superior performance and lower installation costs. With the optional HART Communication Protocol, the iTrans2 offers remote diagnostics, set-up or calibration by superimposing a high-frequency current across the industry standard 4-20mA analog line.
-
product
Gas Permeability Tester
QT-GPT
Gas Permeability Tester- QT-GPT series is used to test the gas transmission rate (GTR) of packaging material by differential pressure method.
-
product
Refrigerant Leak Detector w/ Gooseneck
RLD10
UEi Test & Measurement Instruments
The RLD10 makes pinpointing leaks as easy as one two! Detect leaking refrigerant using the high sensitivity mode then switch to the low sensitivity mode to pinpoint its source. If background noise makes the audible tic hard to hear, you can count on the color scaled LED indicators. With the RLD10 you'll get the latest in refrigerant detection at a great price.
-
product
Mid-Range Gas Filter Correlation CO Analyzer
Model T300M
Teledyne Advanced Pollution Instrumentation
The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.
-
product
Spectrum Monitoring and Interference Detection Software
Supports multiple users; Compartmentalization between profiles; Allows real-time monitoring and generates SMTP alarm traps; Displays a large number of carriers (100+) Numerous RF calculations and monitoring settings; Waterfall Display; Spectrogram Display; OCBW, ACPR, 3dB Bandwidth; Min/Max, Channel Power; Up Time Report; All Major Browsers Supported
-
product
Gas Filter Correlation CO Analyzer
Model N300
Teledyne Advanced Pollution Instrumentation
The Model N300 is a microprocessor-controlled analyzer based on the Beer-Lambert law that is used to determine the concentration of carbon monoxide (CO) in a sample gas.The N300 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb Infrared (IR) light. The analyzer passes the IR light beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.
-
product
Multiple Gas Transformer DGA
MULTITRANS
The MULTITRANS is an 8-gas on-line transformer DGA monitoring unit designed to monitor a bank of three single-phase transformers in close proximity. Based on the same core technology as the highly successful TRANSFIX the MULTITRANS measures all significant fault gases (in ppm) as outlined by international standards as well as moisture in oil (%RH & ppm).
-
product
T6961 DIFFERENTIAL LEAK TESTER ENTRY LEVEL
T6961 was designed for ultra fast testing of small parts (pneumatic valves, pressure switches, micro-valves in plastic for medical use, needles, catheters, biomedical components etc.).This characteristics makes it suitable for use on high production automatic machines, allow assembly of the pneumatic unit behind the part being tested, for maximum reduction of the parasite volume. The differential measurement technology also allows detection of extremely low leaks (example medicinal valves: 10 cc/h at 2 bar in 0.1 s. of testing).
-
product
Lifecycle Services for Humidity, Dewpoint, Trace Gas or Oxygen Measurement Products from PST
Whatever your industry, your location or your measurement product, our global network of service centres with over 50 skilled service engineers will help you locally. We are committed to support you with services that are based on our technical expertise to maintain the reliability, safety and performance of your process control and measurement equipment from one of our trusted brands.
-
product
High Voltage Porosity Detection
High Voltage Technique: The high voltage, or porosity technique, can be used to test coatings up to 25mm (1”) thick and is ideal for inspecting pipelines and other protective coatings. Coatings on concrete can also be tested using this method.
-
product
Fixed Gas Detector
OLCT 80
Teledyne Gas & Flame Detection
Oldham is pleased to propose its wireless system with the OLCT 80 field detector/transmitter. This model allows wireless connectivity in ATEX 1 zones.
-
product
Quick Response Time Combustible Gas Leak Detector w/ Alarm
CD200
UEi Test & Measurement Instruments
The CD200 has a long, slim gooseneck probe and a bright LED tip light to find combustible gas leaks in tight areas. Its adjustable alarm, easy one-hand operation and impact resistant storage case add up to value and convenience.
-
product
Gas Leakage Camera
Zhejiang ULIRvisionTechnology Co., LTD
Gas leakage camera is an instrumentation tool for gas leakage detection. Below are two of our featured gas leak cameras.
-
product
Gas Filter Correlation CO Analyzer
Model T300U
Teledyne Advanced Pollution Instrumentation
The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance analyzer.The optical bench is enclosed in a temperature controlled oven, dramatically decreasing instrument noise and drift. The objective and field mirrors in the sample cell are gold plated to maximize signal to noise performance, while a temperature-controlled Nafion dryer on the inlet minimizes water interference caused by ambient humidity changes. Periodically, the T300U seamlessly corrects its baseline by routing the sample through a heated catalytic CO scrubber. This Auto Reference function corrects zero drift and reduces the effect of interferences.
-
product
Flue Gas Analyzers
Established in 1975, the Telegan brand is well known for its associate with flue gas analysers and HVAC (heating, ventilation and air conditioning) related products. Acquired by Crowcon’s parent company Halma plc in 1993, Telegan has now been fully integrated into Crowcon and benefits from the same quality, engineering and customer support capabilities.
-
product
Mid-Range Gas Filter Correlation CO2 Analyzer
Model N360M
Teledyne Advanced Pollution Instrumentation
The Model N360M measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.
-
product
Recirculating Gas Coolers
Cool your continuous flow cryostat without the need for liquid cryogens.
-
product
Carbon and Sulfur in Inorganic Materials by the Combustion Infrared Detection Technique
744 Series
LECO's 744 Series will redefine the way you determine carbon and sulfur in metals, ores and other inorganic materials. Using extensive customer feedback and innovative engineering, our latest instrumentation takes advantage of an immersive software platform that will increase usability and lower the cost-per-analysis.
-
product
Exhaust Gas Analyzer
IMR 1440FL
IMR Environmental Equipment, Inc.
The exhaust gas analyzer, IMR 1440FL/COFL, is designed to measure exhaust gases of Forklift Trucks, Generators, and heavy Machinery that are powered by a variety of fuels. According to US regulations, the IMR 1440FL/COFL can measure soot and CO for Forklift Trucks.
-
product
Gas Metering Device- Ancillary
TR143 Gas Regulator
The TR143 is a double diaphragm , spring leaded direct acting type regulator with integrated large surface area filter. The optimised valve head, venturi sensor, and low body pressure drop allows maximum capacity flow at very low inlet pressures.
-
product
Stack Gas Analyzer
GI-700 series
Experience HORIBA, the Global Single Source Solutions Provider with over 50 years of technological advancements and unparalleled reliability, dependability and operability.The GI-700 stack gas analyzer is designed to continuously measure the concentrations of nitrogen oxides (NOx), sulfur dioxide (SO2), carbon monoxide (CO), carbon dioxide (CO2), oxygen (O2), and ammonia (NH3) in stack flue gas streams.
-
product
For Detecting Low Range And Leakage AC/DC/Pulsed Current.
FDAZCT-20L-0.6S
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Lowest Influence from Magnetization,Temperature *Change,Residual Current and Terrestrial Magnetism.*Low Cost and High Performance (Output Linearity ±1% F.S)
-
product
Trace Gas Analyzer
PTR-TOF 4000
The new PTR-TOF 4000 is a compact, ultra-sensitive & high-resolution IONICON PTR-TOF real-time trace VOC analyzer. It is our first high-resolution PTR-TOFMS built into the same small and lightweight layout known from our successful PTR-TOF 1000 series. It also features the new hexapole ION-GUIDE technology for increased sensitivity and resolution. The PTR-TOF 4000 thus allows you to benefit from both high mass resolving power and high-sensitivity. Like the other instruments built on this platform also the PTR-TOF 4000 demonstrated its reliability and robustness but also its remarkable technical abilities and speed during various international campaigns (e.g. NASA's KORUS-AQ).





























