Filter Results By:
Products
Applications
Manufacturers
Power Calibration
Verify power measuring instruments accuracy.
See Also: Calibration, Calibrators, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References
- Pickering Interfaces Inc.
product
PXI 10A Power MUX, 1-Bank, 16-Channel
40-661-103
The 40-661 is a single pole power multiplexer module, suitable for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. The multiplexer is available in 8-bank 4-channel, 5-bank 6-channel, 4-bank 8-channel, 2-bank 16-channel and 1-bank 32-channel formats. Also, 4-bank 4-channel, 2-bank 8-channel and1-bank 16-channel half density configurations are available. Signal connections are made via front panel mounted 20-way GMCT plugs.
-
product
RF Calibration Kit
SMK-3000
The SMK calibration kits are precision, high power calibration standards that are used to calibrate RF radios, wattmeters, directional couplers and other high-power RF test equipment in the field or metrology lab. Unlike other calibration solutions, the SMK-3000 calibration kits reduce the cost of ownership and provide a much faster time-to-calibration with lab precision and accuracy you’ve come to expect from Bird.
-
product
10 MHz To 6 GHz LAN Wide Dynamic Range Average Power Sensor
L2051XA
Frequency range of 10 MHz – 6 GHzLAN connectivity with a wide dynamic range of -70 to +26 dBm for small signal measurementsFast real-time measurement of 50,000 readings/secReal-time measurement with zero dead time to ensure every single continuous pulse is measuredAverage mode time-selectivity function allows full dynamic range for average and time selectivity average power measurementsInternal zero and automatic calibration saves time and reduces measurement uncertaintyA BenchVue software license (BV0007B) is now included with your instrument. BenchVue makes it simple to connect, control instruments, and automate test sequences
-
product
Optical Signal Test Set
OST
The Optical Signal Test Set (OSTS) combines a state of the art optical power meter, a variable attenuator, and a high stability laser source. The unit is able to measure optical signals below -100dBm with 0.001dB resolution at a fraction of the size, power, and cost of competing solutions. Other features include data logging, programmable filtering, and auto calibration. Its small shielded ruggedized package, USB/power interface, and low cost make this unit perfect for lab use or for integration into larger systems.
-
product
Flexible Current Sensor Probe
CTA
The CTA current sensors convert ac current to an isolated 0-5A current with available ranges from 100A to 10,000A. Because the current sensors are flexible split core, installation is possible without shutting down the LV electrical supply, avoiding expensive down-time costs. Typical applications are retrospective energy monitoring in factories, offices buildings, process control data logging systems, where power, energy and current monitoring is important. Typical applications are factories, offices buildings, ac/dc VFD drives, welding, power conversion and power distribution. For all CTA current sensor models, a NIST/NPL (UKAS) traceable calibration certificate and certificate of conformance is supplied. All CTA sensors use UL94V0 or CSA approved materials. The CTA flexible current sensors are suited to permanent or semi permanent installation. The coil sensor is durable, lightweight, flexible and will easily clip-around a power cable. The 5A output from the CTA current sensor connects direct to installed metering, rotary metering or current transducers.
-
product
Attenuators And Pulse Limiters
A bidirectional attenuator, i.e. the attenuation and power capability specification is valid for both directions. There is a large variety of applications for this attenuator: The measuring range of a spectrum analyzer can be increased. Any kind of meter can be protected against overload; it can be used to control the linearity of a meter reading. It can minimize measurement uncertainty caused by mismatched impedances. During an EMI receiver calibration an attenuator directly at the pulse generator output is inevitable.
-
product
E-Series Average Power Sensor
E9300B
Measure the average power of all modulation formats Wide dynamic range power measurements from -30 dBm to +44 dBm Frequency range 10 MHz to 18 GHzLow SWR for reducing mismatch uncertainty Calibration factors, linearity and temperature compensation data stored in EEPROM Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
product
Air Quality Analysis
Ambient Gas Monitoring: We offer a variety of analyzers for the ambient monitoring of the criteria pollutant gases, including CO, NOX, SO2, and others such as CH4 and CO2. Source Gas Monitoring (Emissions Monitoring): Experience reliable measurement in your process for emissions compliance every time.Ambient Particulate Monitoring: Experience our monitoring technology and gain the power to do more than just inform.Emissions Calibrators: For continuous monitoring of mercury in exhaust stacks, waste incinerators, and cement kilns, or multi-gas models to control the calibration of gas concentrations.
-
product
Level System
Universal II
The Universal II level transmitter offers increased reliability, low maintenance and an intrinsically safe design for dependable level measurements in all kinds of process liquids, slurries, granulars and interfaces.Universal IIThe Universal II is a two wire level transmitter that eliminates the need for line power in the field and saves costs for additional hardware. It provides reliable level measurements in all kinds of process liquids, slurries, granulars and interfaces.When powered from an approved source this level transmitter can be made intrinsically safe. Its rugged contruction resists corrosion and abraision. The no moving parts design eliminates break downs.The Universal II level transmitter utilizes RF Admittance technology with manual calibration and a 4 – 20 mA output signal. The patented Cote-Shield circuitry ensures accuracy and reliability regardless of product build-up on the level transmitter.This level system is unaffected by changes in the process material density, pressure, or temperature variations.
-
product
Fiber Optic Power Meters
FOD 1202
The FOD 1202 & FOD 1202Si triple wavelength power meters are reliable, rugged and hand-held test product. InGaAs & Si Version with triple wavelength calibration
-
product
10 MHz To 67 GHz USB Wide Dynamic Range Average Power Sensor
U2057XA
Accurately measure any modulated signal with the Keysight Technologies, Inc. U/L2050/60 X-Series wide dynamic range power sensors. The USB/LAN connectivity models come with a wide dynamic range, covering -70 to +26 dBm. This sensor offers very accurate and repeatable power measurements for any modulated signal and comes with a super-fast measurement speed of 50,000 readings/sec, which enables higher manufacturing throughput. Users can also save time and reduce measurement uncertainty with the internal zero and calibration function. The U/L2050/60 X-Series is supported by the Keysight BenchVue software. BenchVue makes it easy to control your power meter to log data and visualize measurements in a wide array of display options without any programming. Simply connect the sensor to your PC installed BenchVue BV0007B Power Meter/Sensor Control and Analysis app to perform average power measurement and analysis.
-
product
Peak and Average Power Sensors
E9320 Series
- Operates with the EPM-P series and P-Series power meters- 300 kHz, 1.5 MHz and 5 MHz video (modulation) bandwidths- Provides peak and average power measurements- Calibration factors stored in EEPROM- Fast measurement speed over the GPIB (up to 1,000 readings per second)- Two frequency ranges: 50 MHz to 6 GHz, and 50 MHz to 18 GHz- Wide dynamic range sensors
-
product
EcoTestr™ pH1 Waterproof Pocket Tester
The economical, simple-to-use pH tester measures pH levels and temperatures quickly, displaying them both simultaneously on a large dual-line LCD. It has a pH range from 0 to 14 with an accuracy of ±0.1 pH. The tester features up to three pH calibration points with auto NIST and US buffer recognition. Additional features include a long-lasting durable electrode with polymer reference electrolyte; status icons for measurement stability, calibration, and battery life; and self-diagnostics. The IP67-rated housing features an easy-to-grip design and floats if accidentally dropped in water when sensor cap is on. The tester, powered by four AAA batteries, can operate up to 400 hours continuously. The unit will auto power-off after 8 minutes of nonuse to conserve power.
-
product
Bench-top Optical Light Source
STC-BTOLS2201 series
Shanghai Stone Communication tech Co., Ltd
STC-BTOLS2201 series high stable Bench-top light source are microprocessor controlled laser diode sources which can support the variety of emitters such as: DFB,FP,PUMP,SLED etc. It is specially used in passive components testing, power meter calibration and general laboratory uses.
-
product
10 MHz To 67 GHz LAN Wide Dynamic Range Average Power Sensor
L2057XA
Accurately measure any modulated signal with the Keysight Technologies, Inc. U/L2050/60 X-Series wide dynamic range power sensors. The USB/LAN connectivity models come with a wide dynamic range, covering -70 to +26 dBm. This sensor offers very accurate and repeatable power measurements for any modulated signal and comes with a super-fast measurement speed of 50,000 readings/sec, which enables higher manufacturing throughput. Users can also save time and reduce measurement uncertainty with the internal zero and calibration function. The U/L2050/60 X-Series is supported by the Keysight BenchVue software. BenchVue makes it easy to control your power meter to log data and visualize measurements in a wide array of display options without any programming. Simply connect the sensor to your PC installed BenchVue BV0007B Power Meter/Sensor Control and Analysis app to perform average power measurement and analysis.
-
product
VFL Power Meter -- VFL & OPM
TM203N
◇ Self Calibration◇ Self Auto Off◇ High Accuracy, high ,High sensitivity, high linearity-◇ Stable VFL Output◇ Set the REF Value◇ Real-time display of the power consumption◇ Interchangeable connectors: FC/ SC◇ Rubber Out shell, increased the protective properties for field work
-
product
E-Series Average Power Sensor
E9301H
Measure the average power of all modulation formats Wide dynamic range power measurements from -50 dBm to +30 dBm10 MHz to 6 GHz frequency coverage for Wireless Comms formatsLow SWR for reducing mismatch uncertainty Calibration factors, linearity and temperature compensation data stored in EEPROM Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
product
Cross Voltage Testers
designed to perform the 60 Hz power line cross test/AC power fault tests required in GR 1089 issue 6 table 4.5 surge test 3,4, 4.3,and 6, and for UL 1950 section 6.4 paragraph 3 and 4.. Preset and Adjustable Time Settings Measuring Terminals including Voltage Sense and Current Shunt portals provide a safe location for users to accurately measure test voltages and output current while setting up tests. Calibration of the Mini_PT-600 is designed to be performed with a simple handheld multi-meter and the removable Currents Shunts can be easily sent to a calibration laboratory if required.
-
product
Stand Alone/ Bench Top Load Cell Amplifier/ Conditioner Module
MODEL TMO-2A
The TMO-2A Transducer Modules is a complete differential amplifier/signal conditioners with self contained power. The unit provide excitation, balance and span adjustment via precision 10 turn pots, and shunt calibration necessary to couple a user supplied bridge type transducer to an indicating instrument. Zero to full scale output is specified at 4-20 mA. The TMO-2A provides a floating shunt calibration circuit which applies calibration at the transducer, thereby eliminating errors due to line losses. The excitation supply incorporates a Wagner Ground to greatly improve Common Mode Rejection. The factory set bandwidth of the module is narrow to improve stability. The removal of a single capacitor will increase the frequency response DC to 60K Hz for dynamic data applications.
-
product
Power and energy calibrators
Three or single phase electric power/energy calibrator with power quality functions for calibration and testing of grid measuring appliance like power meters, power transducers or power quality analysers.
-
product
ORPTestr® 5 Waterproof Pocket Tester
The pocket-sized OPR tester has a replaceable single-junction sensor which can be easily switched out, allowing you to save money by using the tester body over and over again. A large LCD makes viewing measurements easy and features a three-color backlight indicating operational mode—blue for measurement, green for calibration and red for alarm condition. It is ideal for checking dirty water, heavy metals, sulfides, and organic materials. Additional features include hold function to lock in measurements, self-diagnostic error message, and status icons for measurement stability and low battery voltage. The IP67-rated housing features an easy-to-grip design and floats if accidentally dropped in water when sensor cap is on. Powered by four AAA batteries, the testers can operate up to 400 hours continuously. To conserve power, the unit will auto power-off after 8 minutes of nonuse.
-
product
Waveguide Power Sensor
R8486D
Excellent SWR for reducing mismatch uncertainty50 MHz calibration port Accurate calibration and traceability to US National Institute of Standards and Technology (NIST) millimeter-wave sensor calibration Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters, plus the E1416A VXI and discontinued 70100A and 43X power meter Accurate average power measurements over -70 to -20 dBm Frequency range 26.5 GHz to 40 GHz Diode power sensing element
-
product
Coaxial Dual-Directional Coupler, 2 GHz to 18 GHz
772D
The Keysight 772D is a high-performance, dual-directional coupler designed for broadband swept measurements in the 2 to 18 GHz range. This coupler can be combined with Keysight power sensors and power meters for reflectometer applications. Forward and reverse power measurements on transmitters, components, or other broadband systems are made simpler using the Keysight 772D. The broadband design allows the use of a single test setup and calibration for tests spanning the entire 2 to 18 GHz range.
-
product
Power Measurement
Precision Acoustics manufactures Radiation Force Balances and Check Sources which can be used to measure ultrasound power according to the IEC Standard 61161. All products are supplied with a calibration from The National Physical Laboratory, LONDON.
-
product
Digital Indicator for Strain Gauge Sensors
AD-4530
Low cost digital indicator for various applications. Suitable for measurement of load, pressure, torque, tension and more at an affordable price.Digital Zero (DZ) stores zero data at any measurement point. This function can also be used to tare weight. Measurement can simply be restarted when it was interrupted by a loss of power.Power on zero function adjusts to zero when the power is turned on.Digital filter provides stable measurement results.Digital span calibration. Easy calibration just by inputting the rated output of a sensor. No need to use a mass.
-
product
Fully Automatic Colorimeter
DRK103C
Shandong Drick Instruments Co., Ltd.
(1)5 inch TFT color LCD touch screen, the operation is more humanized, new users can be mastered in a short period of time using the method.(2)Simulation of D65 lighting lighting, using CIE1964 complementary color system and CIE1976 (L*a*b*) color space color difference formula.(3)The motherboard brand new design, using the latest technology, CPU uses 32 bits ARM processor,improve the processing speed, the calculated data is more accurate and rapid electromechanical integration design, abandon cumbersome testing process of the artificial hand wheel is rotated, the real implementation of the test program, a determination of the accurate and efficient.(4)Using d/o lighting and observation geometry, diffuse ball diameter 150mm, diameter of the testing hole is 25mm.(5) A light absorber, eliminate the effect of specular reflection.(6)Add printer and imported thermal printer, without the use of ink and color, no noise when working, fast printing speed.(7) Reference sample can be physical, but also for data,? Can store up to ten only memory reference information.(8) Has the memory function, even if the long-term shutdown loss of power, memory zeroing, calibration, standard sample and a reference sample values of the useful information is not lost.(9) Equipped with a standard RS232 interface, can communicate with computer software.
-
product
MPI Fully Automatic Probe Systems
MPI Advanced Semiconductor Test
Addressing the RF and High Power communication devices and discrete passive components production test market requirements, MPI introduced the TS2500 200 mm fully automatic probe system series. The system is based on industry leading production equipment from the Photonics Automation Division and incorporates decades of experience in RF and High Power measurement techniques from the MPI’s Advanced Semiconductor Test (AST) Division in combination with other AST products such as RF Probes, related calibration technology, and High Power accessories.
-
product
Single-Channel Voltage Output D/A Converters
Analog Devices offers a broad portfolio of single-channel voltage D/A converters, which includes many leading products in performance and package size, with resolutions from 8-bit to 20-bit, low power, and a serial SPI, parallel, or I2C interface. Within the industry’s smallest packages, we offer more functionality within smaller board and module sizes. The integration of a precision reference minimizes board area and costs, eliminates the need of calibration, and reduces the number of external components to simplify the design stage.
-
product
Antenna Measurement Software
Raymond RF's Antenna Measurement Software performs 2-D (polar/rectangular) and 3-D (spherical) antenna pattern measurements for passive antennas and active wireless mobile stations (cell phones). Insertion loss of passive devices is included as part of the calibration component. Data management and reporting of antenna properties such as half power beam-width, directivity, gain, radiation efficiency, total radiated power, and total isotropic sensitivity. AMS performs and reports all measurements required by the CTIA Over-the-Air Performance Test Plan.
-
product
Deskew Calibration Source for CP030, CP030A, CP031, CP031A, AP015, CP150, CP500
DCS025
The DCS025 Deskew Calibration Source generates time-aligned voltage and current pulses for precise deskew of voltage and current probes.This is critical for measurements in which small propagation delay differences between probes can have a large impact on a calculated measurement, e.g., instantaneous power semiconductor device loss measurements.
-
product
Diode Power Sensor
8487D
Excellent SWR for reducing mismatch uncertainty Accurate calibration and traceability to US National Institute of Standards and Technology (NIST) millimeter-wave sensor calibration Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters, plus the E1416A VXI and discontinued 70100A and 43X power meter Accurate average power measurements over -70 to -20 dBm Frequency range 50 MHz to 50 GHzDiode power sensing element